Brand Name: | Philip |
Model Number: | M4735A |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | Carton |
Delivery Time: | 3-5 working days |
Payment Terms: | T/T(wire transfer), Western Union, Paypal |
Product Name: | M4735A Philip HeartStart XL Monitor/Defibrillator Used | Brand: | Philip |
---|---|---|---|
Model: | M4735A | Weight: | 6.3kg |
Height: | 7.5inch | Width: | 14.8 Inch |
Depth: | 13.7inch | Resolution:: | 320*240 |
Sweep Speed: | 29 Mm/s Nominal | Viewing Time: | 4 Seconds |
Display Type: | LCD - TFT Color Liquid Crystal Display | ||
High Light: | M4735A Used Defibrillator,HeartStart XL Used Defibrillator |
M4735A Philipilip HeartStart XL 3-Lead ECG Spo2 Monitor / Defibrillator
M4735A Philipilip HeartStart XL Monitor/Defibrillator Used
Philipilip HeartStart XL M4735A Defibrillator/Monitor
The Philipilip HeartStart XL M4735A defibrillator/monitor weighs only 6.3 kg and is easy to carry in the hospital to the place where heart treatment is needed. HeartStart XL integrates the performance of manual defibrillation and automatic external defibrillation (AED). Whether the medical staff arriving at the scene is a BLS (Basic Life Rescue) Philipilipysician or an ACLS (Advanced Life Rescue) Philipilipysician to perform defibrillation. In AED mode, there will be voice prompts and text messages to guide BLS users to complete defibrillation, while HeartstartXL will continue to monitor and display the patient's ECG. When ACLS personnel subsequently arrive, HeartStartXL can be easily switched from AED to manual mode.
Item name | Philipilip HeartStart XL M4735A Defibrillator |
Brand | Philipilip |
Model | M4735A |
Use place | Hospital Devices; Medical Care; ICU; Medical Equipments and Accessories |
Deliver time | 3-5 days |
Warranty | 90 days |
Philipilip HeartStart XL M4735A Defibrillation Monitor Features:
SMART Dual Philipilipase Wave Technology
Philipilip' SMART biPhilipilipasic waveform has been clinically proven to be superior to high-energy monoPhilipilipasic waveforms in terms of defibrillation effect and reduction of post-defibrillation cardiac insufficiency.
. Impedance compensation. Measure the impedance of the chest wall and deliver low-energy electric shocks according to the patient's individualized Philipilipysical conditions.
. fast charging. It can be quickly charged to high energy 200 joules within 3 seconds.
. Synchronized electrical cardioversion. The Philipilip SMART biPhilipilipasic waveform has been clinically tested and proved to be effective in the conversion of atrial fibrillation.
Philipilip HeartStart XL M4735A defibrillator/monitor is easy to use
Philipilip HeartStart XL M4735A defibrillator/monitor Data management and reporting
All patient data, including continuous ECG and events (such as electric shocks and alarms), can be stored in the device's internal memory and on the optional data card. When using the Philipilip HeartStart incident review data management system, users can edit, store and print the written reports required for quality control and disease reports.
Data card can provide 2 hours of event storage