New and Original Philip M2741A Sidestream CO2 Sensor Good in Function Medical Device Hospital Equipment​

New and Original Philip M2741A Sidestream CO2 Sensor Good in Function Medical Device Hospital Equipment​

  • New and Original Philip M2741A Sidestream CO2 Sensor Good in Function Medical Device Hospital Equipment​
  • New and Original Philip M2741A Sidestream CO2 Sensor Good in Function Medical Device Hospital Equipment​
  • New and Original Philip M2741A Sidestream CO2 Sensor Good in Function Medical Device Hospital Equipment​
  • New and Original Philip M2741A Sidestream CO2 Sensor Good in Function Medical Device Hospital Equipment​
New and Original Philip M2741A Sidestream CO2 Sensor Good in Function Medical Device Hospital Equipment​
Product Details:
Brand Name: Philip
Model Number: M2741A
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: Philip Sidestream CO2 Sensor Type: M2741A
Use With Non-Philip Healthcare Equipment: No Product Type: CapnograPhilipy
MOQ: 1pcs Single-Patient Use OR Multi-Patient Use: Multi-Patient Use
CE Certified: Yes Package Weight: 0.610 Kg
Packaging Unit: 1 Sensor Not Manufactured With Natural Rubber Latex: Yes
Minimum Shelf Life: None Sterile OR Non-Sterile: Non-Sterile
Technology: Sidestream Warranty: 90days
Product State: In Good Working Order

 

Philipilip Sidestream M2741A CO2 Good in Function​ Medical Device Hospital Equipment​ 

 

► Brief Introduction

The Philipilip M2741A Sidestream CO2 sensor uses advanced infrared absorption spectroscopy to measure CO2 and respiration rate. The sensor provides a clear, accurate carbon dioxide map that shows respiration rates of up to 150 breaths per minute. The amplification rate was 50 ml/min, which is ideal for infants and small patients.

 

The Sidestream CO2 sensor is used in conjunction with the Philipilip Carbon Dioxide Analysis Measurement Server Extension (M3014A) and in conjunction with the Intellivue Multifunction Measurement Server.

 

Use with Philipilip Healthcare Equipment: 860335, M3014A, M8105A, M8102A, M3002A

 

 

► Features and benefits

• Compatibility: Philipilip Sidestream M2741A CO2 Sensor is compatible with the entire Intellivue patient monitor family (issued D.0 or later)

• Innovation: Connect the sampling pool and filter to the disposable sampling kit to prevent fluid contamination of the sensor

• Simple: Plug and play functionality; Intuitive and easy to use without regular calibration

• Application environment: Suitable for general wards, ICU, CCU, ER, OR and EMS

• Reliable: Provides clear, accurate CO2 measurements

• Reliable: rugged solid state design

New and Original Philip M2741A Sidestream CO2 Sensor Good in Function Medical Device Hospital Equipment​ 0New and Original Philip M2741A Sidestream CO2 Sensor Good in Function Medical Device Hospital Equipment​ 1

 

 

► Quick Details

 

Initialization time Full specifications within two minutes, waveform data in less than 20 seconds
at an ambient temperature of 25°C
CO measurement range 0 to 150 mmHg, 0 to 19.7%, 0 to 20 kPa (at 760 mmHg)
CO2 accuracy 0-40 mmHg ≥ 2 mmHg
41-70 mmHg ≥ 5% of reading
71-100 mmHg ≥ 8% of reading
101-150 mmHg ≥ 10% of reading
Note: All specifications are ≥ 12% for respiration rates above 80 BPM
Sample flow rate 50 ml/min ≥ 10 ml/min
CO stability Short-term drift: drift over four hours shall not exceed 0.8 mmHg
Long-term drift: accuracy specification will be maintained over a 120-hour period
Calibration No routine user calibration required
Philipilipysical characteristics Height: < 38.1 mm
Width: < 66.1 mm
Depth: < 88.9 mm
Temperature and humidity Operating: 0 to 40°C, 10 to 90% RH, non-condensing
Storage: 40 to 70°C, <90% RH, non-condensing
Water resistance (sensor) IPX4-Splash-proof
Shock resistance IEC TR 60721-4-7 Class 7M
IEC 60068-2-27 Shock
Data output CO2 gas concentration (mmHg), end-tidal CO2, inspired minimum CO2,
airway respiratory rate

 

 

► Packing Instructions

All machines and units are delivered on pallets or carton so as to make sure the safety to the full extent during the transmission. As a international manufacturer, we deliver medical equipment all over the world, insured and tracked as standard using trusted couriers. In order to ensure that the goods are delivered to customers in good condition, we will carefully and patiently pack the products. Please rest assured that we will use high-quality packaging materials to pack the goods to avoid being scratched or impacted during transportation. Generally speaking, there is no problem with the goods you receive. But if you find any problems with the goods during transportation, please contact us as soon as possible. But please pay special attention, if the problem is not caused by transportation, it is another matter. In short, after careful inspection by our engineers and our careful packaging, the goods will eventually arrive in your hands intact.

 

 

► Shipping Instructions

Regarding the delivery date, we will try our best to handle the order and deliver the goods as soon as possible. Please be patient and keep in touch with us. Generally speaking, most orders are delivered within 3 - 5 working days and can arrive on time. However, on busy days, shipment may be delayed by more than five working days. If you are in urgent need of your products, please make sure to confirm with us before placing an order. In order to ensure the smooth operation of the business, please pay special attention and arrange the order time carefully according to your personal needs. If your order takes longer than expected, or you want to know when it will arrive, please feel free to contact us. We are always here to help you.

 

 

► Our Major Business

We are mainly engaged in the sales and maintenance of various medical equipment, accessories and maintenance accessories, including patient monitors, defibrillator machines, patient monitor printers, electrocardiograPhilipilips, electrocardiograPhilipilips, motherboards, batteries, etc. After years of market promotion and development, we have become quite proficient in medical device technology. Our products are becoming more and more popular and enjoy a good reputation at home and abroad. With superior product quality and reasonable prices, our sales have grown steadily year by year. We are a reliable manufacturer, providing the best products and services to customers all over the world. Satisfying all customer needs is our eternal pursuit.

 

 

► Quality Guarantee

Our company have one division of labour on the basis of specialization, highly cooperative group, rich technical force of medical machines development. Our expert team provides prompt, dependable solutions for sales and repairs on patient monitor, defibrillator machine, ECG/EKG machine and other accessories or repair parts. We have been always focusing on producing superior products and providing first-class customer service. What calls for special attention is that there are both brand new and second-hand products for sell. Please remember to carefully distinguish them when placing your orders. Otherwise, it will cause unnecessary troubles. If you have any doubts about the product quality, please don’t hesitate to contact us. We will reply to you as quickly as possible.

 

 

► About Disclaimer

To ensure the smooth and effective conduct of the transaction, please understand and agree to the following terms. There are two main things you need to know. First of all, you'd better remember to patiently browse all the product pictures when you buy, so that you can confirm that the product you are looking for is what you are looking for and need to buy. This is absolutely necessary, because the product picture is also essential in the product description, which can help you understand the product more intuitively and in more detail. The second thing is customs fees. Please note that the buyer is responsible for all customs charges such as taxes. Therefore, before paying for the order, you must check whether the equipment you ordered is allowed to be imported into your country. That is, remember to read all the relevant information before ordering.

 

Please kindly contact us, if you are interested in Philipilip Sidestream M2741A CO2 Sensor. Thank you !

 

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: 8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.