Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Accessories

Philip CAPNOSTAT M2501A Patient Monitor CO2 Sensor compatible in Good Shape Medical Device Hospital Equipment​

Philip CAPNOSTAT M2501A Patient Monitor CO2 Sensor compatible in Good Shape Medical Device Hospital Equipment​

  • Philip CAPNOSTAT M2501A Patient Monitor CO2 Sensor compatible in Good Shape Medical Device Hospital Equipment​
  • Philip CAPNOSTAT M2501A Patient Monitor CO2 Sensor compatible in Good Shape Medical Device Hospital Equipment​
  • Philip CAPNOSTAT M2501A Patient Monitor CO2 Sensor compatible in Good Shape Medical Device Hospital Equipment​
  • Philip CAPNOSTAT M2501A Patient Monitor CO2 Sensor compatible in Good Shape Medical Device Hospital Equipment​
  • Philip CAPNOSTAT M2501A Patient Monitor CO2 Sensor compatible in Good Shape Medical Device Hospital Equipment​
Philip CAPNOSTAT M2501A Patient Monitor CO2 Sensor compatible in Good Shape Medical Device Hospital Equipment​
Product Details:
Brand Name: Philip
Model Number: M2501A
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: Philip CAPNOSTAT M2501A Patient Monitor CO2 Sensor Type: M2501A
Application: Medical Equipment,ICU,hospital Device Warranty: 90days
Color: White Tag: Patient Monitor Finger Sensor
Major Material: Plastic, Fireproof Materials Application Context: Emergency Operation Room,Clinic Operating Theatre ,Hospital, Clinic, Hospital Room, ICU,etc
Advantages: Professional Technical Team Post-sales Service: Online Technical Support Service
Language: Multi Language Support Product State: Running Sweetly
Nominal Voltage: 110V—240v Power Source: Electricity
Specialty: Durable,professional,reliable
High Light:

Patient Monitor CO2 Sensor

,

M2501A CO2 Sensor

 

Philipilip CAPNOSTAT M2501A Patient Monitor CO2 Sensor​ in Good Shape​ Medical Device Hospital Equipment​ 

 

 

► Brief Introduction

The Philipilip M2501A mainstream CO2 sensor uses a complex infrared absorption spectrum to measure EtCO2. The measurement is performed on the patient's airway, so the response is faster and the possibility of errors and human data is less. With no moving parts, the sensor is durable and provides reliable readings you can rely on.

 

M2501A Mainstream CO2 Sensor Specifications

Initizlization Time: Full specifications wihin 2 minutes, waveform date in less than 15 seconds at an ambient temperature of 25°C
CO2 Measurement: 0 to 150mm Hg, 0 to 20kPa (at 750mm Hg)
CO2 Accuracy: 0-40mm Hg +/- 2mm Hg
41-70mm Hg +/- 5% of reading
71-100mm Hg +/- 8% of reading
101-150mm Hg +/- 10% of reading
CO2 Stability: Short Term Drift: Drift over 4 hours shall not exceed 0.8mm Hg max.
Long Term Drift: Accuracy specification will be maintained over a 120-hour period
Calibration: No routine user calibration required. 15-second airway adapter zero performed when changing to a different style of airway adapter.
Philipilipysical Characteristics: Sensor weight less than 25gm (not including cable)
SizeL 33mm(H) x 48mm(W) x 23mm (D)
3 Meter (9.8ft) cable standard
Temperature and Humidity: Operating: 0 - 45°C, 10 to 90% RH, Non-condensing
Storage: -40 to 70°C, <90% RH, Non-condensing
Water Resistant (Sensor): IPX4 - Splash - proof
Shock Impact: Able to withstand repeated 6-foot(1.8m) drops onto tiled floor while operating.
Date Output: Real time, linearized, calibrated CO2 gas concentration (mm Hg), End-tital CO2, Inspired CO2, Respiratory Rate.
Gas and barometric pressure compensated.
Selectable compensations for O2 (0-100%) and N2O (On/Off) and He (On/Off)

Philip CAPNOSTAT M2501A Patient Monitor CO2 Sensor compatible in Good Shape Medical Device Hospital Equipment​ 0

 

► Buyer Reading

Dear customers, To make sure the deal runs successfully and efficiently, please learn about and agree to the following clauses and terms. There are mainly two important things that you need to know well. The first thing is that you’d better bear in mind to look through all the product pictures with patience when purchasing so that you can confirm the item you are viewing is just what you are looking for and need to buy. It is absolutely necessary to do so as product pictures also play essential roles in product description, which helps you understand the product more intuitively and detailedly. The second thing comes to the customs fees. Please kindly know that the buyer is responsible for the customs fees such as all taxes and duties. Consequently, before paying for orders you must check out that the equipment your are ordering is allowed to imported into your country. That is to say, remember to read all the relevant information before ordering. Thanks for Your Cooperation.

 

 

► Delivery instructions

Regarding the delivery time, we will do our best to process the order and ship it as soon as possible. Please be patient and keep in touch with us. Generally speaking, most orders are shipped within 3-5 working days and can arrive on time. However, on busy days, shipment may be delayed by more than 5 working days. If you need your products urgently, please confirm with us before placing an order. In order to ensure the smooth progress of the business, please pay special attention to your company and carefully arrange the order time according to your personal needs. If your order is longer than expected, or you want to know when it will arrive, please feel free to contact us. We are always here to help you.

 

 

► Packing Standard

In order to ensure that the goods are delivered to customers in good condition, we will pack the products carefully and patiently. Please rest assured that we will use high-quality packaging materials to pack the goods to avoid scratches or shocks during transportation. In general, there is no problem with the goods you received. But if you find any problems during the transportation of the goods, please contact us as soon as possible. But please pay special attention, if it is not a problem caused by transportation, it is another matter. In short, after careful inspection by our engineers and careful packaging, the goods will eventually be delivered to you intact.

 

 

► Warranty Issues

Please note that new and used medical machines are sent out for at least 90 days warranty period. They are not allowed to leave the workshop completely by our engineers will test each machine with the most concerned and unit, and ensure that they are 100% effective equipment. Of course, we are confident that you will be satisfied with our products and services. But if you are not, please contact us as soon as possible, if you find any problems. Our ultimate goal is to develop and sell the best products to customers around the world. Customer satisfaction is our biggest pursuit.

 

 

► Some Warm Tips

As an experienced medical device industry expert, Apart from specializing in selling medical devices, accessories and repair parts such as patient monitor, defibrillator machine, patient monitor printer, ECG machine, EKG machine, main board, batteries and so on, we also engage in providing medical equipments or modules repair service. So if you have any that sort of machine or modules which in need of repair, please feel free to contact us at any time. Moreover, what need to pay attention to is that you have to make sure the repair item is unopened and has never been repaired before. And items lack of component is unacceptable. Accordingly, check out your item before shipping.

 

Any inquiry for Philipilip CAPNOSTAT M2501A Patient Monitor CO2 Sensor will be highly appreciated and thanks for your support. Thank you for your time!

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: 8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.