Brand Name: | Mindray |
Model Number: | 122009708 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | Carton |
Delivery Time: | 3-5 working days |
Payment Terms: | T/T(wire transfer), Western Union, Paypal |
Product Name: | Mindray MOX-4 MOX4 O2 Oxygen Sensor Cable 122009708 | Brand: | Mindray |
---|---|---|---|
Part No: | 122009708 | Operating Principle: | Partial Pressure Electrochemical |
Output: | 9 MV To 13 MV In 210 MBar O2 | Measurement Range: | 0 MBar To 1500 MBar O2 |
Baseline Offset: | <200 μV | Condition: | New |
MOQ: | One Piece | Warranty: | 90 Days |
High Light: | 122009708 MOX-4 Oxygen Sensor Cable,122009708 Oxygen Sensor Cable |
Mindray MOX-4 Oxygen Sensor Cable 122009708
About Mindray MOX-4 Oxygen Sensor Cable 122009708
The Mindray MOX-4 Oxygen Sensor Cable is a replacement cable used with the Mindray MOX-4 oxygen sensor. This cable is designed to
provide a reliable connection between the sensor and the monitoring device, ensuring accurate and consistent oxygen level readings. It is an
essential component for patient monitoring in hospital settings and healthcare facilities.
Specification of Mindray MOX-4 Oxygen Sensor
MEASUREMENT | |
Operating Principle | Partial pressure electrochemical |
Output | 9 mV to 13 mV in 210 mBar O2 |
Measurement Range | 0 mBar to 1500 mBar O2 |
Baseline Offset | <200 μV |
ENVIRONMENTAL | |
Typical Applications | Critical care anesthesia |
Operating Temperature Range | Range -20°C to +50°C |
Operating Pressure Range | 0.5 Bar to 2.0 Bar |
Operating Humidity Range | 0% to 99% RH noncondensing |
Purpose of use
These sensors are designed for oxygen partial pressure monitoring in anesthesia (except xenon), intensive care, neonatal incubators and general
oxygen monitors.
Stabilization time.
Wait at least 15 minutes for the instrument to stabilize before calibrating or refer to the manufacturer's instructions.
Cleaning and sterilization
If the sensor is dirty, clean it with distilled water and allow it to air dry. This sensor is not suitable for steam sterilization or exposure to chemicals
such as ethylene oxide or hydrogen peroxide.
Calibration interval
If the sensor is dirty, clean it with distilled water and allow it to air dry. This sensor is not suitable for steam sterilization or exposure to chemicals
such as ethylene oxide or hydrogen peroxide.
If you drop the sensor
If a sensor is dropped, it must be isolated for 24 hours and then a two-point calibration performed.
mechanical installation
When installing the sensor, simply screw it in tightly by hand to ensure a tight seal. Do not use wrenches or similar mechanical devices as
excessive force may damage the sensor threads.
Photos
Below picture is Mindray City MOX-4 MOX4 O2 Oxygen Sensor Cable 122009708 New .The cable condition is new .
About us
CWT Technology HK Limited is a developing company ,mainly selling patient monitor ,ECG ,defibrillator ,ultrasound ,spare parts ,accessories
.With the developing ,our customers are from all over the world,such as USA ,Italy ,Spain ,Malaysia ,Philippines,Indonesia ,Thailand ,Colombia
,Saudi Arabic ,United Arab Emirates ,Oman etc .
Thank you so much for your attention .If you're interested in Mindray MOX-4 MOX4 O2 Oxygen Sensor Cable 122009708 ,feel free to contact us .Thank you .
Contact Person: Kiara
Tel: 8619854815217