logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

Fi-sher Paykel Ventilator HC254 SleepStyle 250 Auto CPAP Humidifier

Fi-sher Paykel Ventilator HC254 SleepStyle 250 Auto CPAP Humidifier

  • Fi-sher Paykel Ventilator HC254 SleepStyle 250 Auto CPAP Humidifier
  • Fi-sher Paykel Ventilator HC254 SleepStyle 250 Auto CPAP Humidifier
  • Fi-sher Paykel Ventilator HC254 SleepStyle 250 Auto CPAP Humidifier
Fi-sher Paykel Ventilator HC254 SleepStyle 250 Auto CPAP Humidifier
Product Details:
Brand Name: Fi-sher Paykel
Model Number: SleepStyle 250 (HC254)
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,Paypal
Contact Now
Detailed Product Description
Pressure Range: 4 To 20 Cm H₂O Pressure Adjustment: 0.5 Cm H₂O Increments
Water Chamber Capacity: 400 ML Power Supply: 100–240 V AC, 50/60 Hz
Condition: New Original Warranty: 90 Days
Lead Time: 3~5 Days Payment: T/T, Western Union,Paypal
Color: White Device Type: Auto Adjusting CPAP (APAP)
Highlight:

Fisher Paykel HC254 Ventilator

,

SleepStyle 250 Auto CPAP Humidifier

,

CPAP Humidifier Patient Monitor Parts

 

Fi-sher Paykel Ventilator HC254 SleepStyle 250 Auto CPAP Humidifier

 

Introduction

 

The HC254 is a sophisticated breathing assistant that doesn't just deliver a fixed stream of air. It uses a motorized fan assembly to provide positive airway pressure, with the fan speed directly controlled by software to adjust pressure based on the patient's needs throughout the night. The device monitors for apneas, hypopneas, and flow limitation, automatically adjusting the pressure to keep the airway open.


It uses a heated passover system to add moisture to the air, improving comfort and helping to reduce dryness in the nose and throat. Adjusts the heater plate to maintain optimal humidification as room temperature changes, and helps reduce condensation in the breathing tube.

Fi-sher Paykel Ventilator HC254 SleepStyle 250 Auto CPAP Humidifier

Advantages

1. The HC254 utilizes an airflow based automatic adjustment algorithm. It continuously monitors for apneas, hypopneas, and airflow limitations, adjusting pressure accordingly to keep your airway open. This means you don’t need to worry about manual settings,the device provides exactly the right amount of pressure, precisely when you need it.

 

2. A standout feature of this device is its ability to recognize breathing patterns that indicate you are in an "anxious" or wakeful state. When such patterns are detected, the device promptly reduces pressure, helping you drift back to sleep more comfortably and preventing the discomfort of being jolted awake by sudden pressure fluctuations.

 

3. The SleepStyle is equipped with an expiratory pressure relief function. As you exhale, the device automatically lowers the pressure slightly, making the act of breathing out feel more natural and effortless. Combined with a low-inertia motor, this ensures an exceptionally smooth and quiet breathing experience.

 

Initial Setup

 

  • Placement: Place the device on a low shelf or on the floor beside your bed, ensuring it is positioned below head height. This is crucial to prevent water from the humidifier from entering the breathing tube if the device is knocked over.
  • Humidifier Chamber: Remove the chamber by pressing the release button. Fill it with distilled or demineralized water up to the maximum line, then slide it back into the device until it clicks into place.
  • Air Filter: Ensure the air filter is fitted at the back of the device before operating it.
  • Breathing Tube & Mask: Connect the AirSpiral breathing tube to the outlet on the device and attach your mask to the other end.

For Cleaning 

 

  • Unplug the device from mains power.
  • Remove the breathing tube from the chamber and the mask.
  • Press the button to release and remove the humidification chamber for cleaning

Keep in Mind

1. The water chamber and breathing tube should be cleaned daily with warm, soapy water to prevent mold and bacteria growth. Once a week, the chamber should be soaked in a solution of one part white vinegar to two parts water for 10 minutes for a deeper clean.

 

2. Replace the water chamber regularly. Replacing the water chamber every six months, or sooner if the plastic walls become cracked, discolored, or the base becomes pitted.

 

3. Manage condensation. If you notice water collecting in the tube, the humidity setting may be too high for the room conditions. Try lowering the humidity setting slightly, ensuring the device isn't in a cool draft, or warming the room.

 

4. The air filter needs periodic replacement. Check the filter at the back of the device. It should be replaced when it becomes significantly discolored, at least once every three months or after 1,000 hours of use.

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: +8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.