China World Technology Medical Equipment Service Group
Win-win together!
| Brand Name: | Aeonmed |
| Model Number: | EP520 |
| Minimum Order Quantity: | 1 |
|---|---|
| Delivery Time: | 3-5 working days |
| Payment Terms: | T/T, Western Union,Paypal |
| Name: | Micro Injection Pump | Infusion Modes: | ML/h, Drops/min, And V-T |
|---|---|---|---|
| Flow Rate Range: | 1 – 49.9 ML/h;50 – 1200 ML/h | BOLUS / PRIME Rate: | 100 – 900 ML/h, Accuracy ±5% |
| Occlusion Alarm: | Three Selectable Levels: High / Medium / Low | Warranty: | 90 Days |
| Display: | 3.9-inch LCD | Battery Runtime: | ≥5 Hours At 25 ML/h |
| Weight: | 2 Kg | Color: | White |
| Highlight: | Micro Injection Syringe Pump EP520,Single Channel Syringe Pump,EP520 Syringe Pump Patient Monitor |
||
Aeonmed Micro Injection Syringe Pump EP520 Single Channel
Introduction
The Aeonmed EP520 is a lightweight volumetric infusion pump capable of precisely controlling the infusion flow rate (or drip rate), ensuring that medication is delivered into the patient's body at a consistent speed, in an accurate dosage, and in a safe manner. For use in situations where the volume of fluid and the dosage of medication must be strictly controlled.
![]()
Features
1. The device is equipped with a 3.9 inch, high contrast LCD screen that displays the infusion rate, volume infused, total volume to be infused, and operating status in large, easy to read text.
2. Operation follows a simple three steps logic: Power On → Set → Start.
3. This infusion pump supports one-handed setup, which helps reduce preparation time in emergency situations.
4. With ICUs crowded with equipment and limited space, the EP520 offers high space efficiency. Weighing less than 2 kg
5.The pump adds a V-T (Volume-Time) mode, and in the V-R (Volume-Rate) mode it allows the user to choose "mL/h" or "drops/min" for infusion.
6. It supports not only dedicated imported infusion sets but also standard PVC infusion sets, better meeting clinical needs.
Loading and starting an infusion
1. Open the pump door using the release latch.
2. Insert the tubing into the pump's tubing channel, following the directional markings. Push the anti free flow clip down, then stretch the tubing gently and fix it into the grooves at both ends. Close the anti-free-flow clip to clamp the tube.
3. Close the door firmly until it latches the pump will pop up the infusion tube selection interface, indicating correct installation.
4. Power on the pump. The system will run a self test of the motor, sensors, battery, memory, and alarm indicators.
5. Select the infusion mode (mL/h, drops/min, or V-T) and set the rate and preset volume.
6. Remove air bubbles from the line and connect the infusion line to the patient.
7. Press start to begin the infusion.
Notice
Contact Person: Rita
Tel: +8618279091952