logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

GE Datex-Ohmeda Anesthesia Vaporizer Bypass Valve Hanger Bracket Assembly Vapor Manifold 2080006-001

GE Datex-Ohmeda Anesthesia Vaporizer Bypass Valve Hanger Bracket Assembly Vapor Manifold 2080006-001

  • GE Datex-Ohmeda Anesthesia Vaporizer Bypass Valve Hanger Bracket Assembly Vapor Manifold  2080006-001
  • GE Datex-Ohmeda Anesthesia Vaporizer Bypass Valve Hanger Bracket Assembly Vapor Manifold  2080006-001
  • GE Datex-Ohmeda Anesthesia Vaporizer Bypass Valve Hanger Bracket Assembly Vapor Manifold  2080006-001
  • GE Datex-Ohmeda Anesthesia Vaporizer Bypass Valve Hanger Bracket Assembly Vapor Manifold  2080006-001
  • GE Datex-Ohmeda Anesthesia Vaporizer Bypass Valve Hanger Bracket Assembly Vapor Manifold  2080006-001
GE Datex-Ohmeda Anesthesia Vaporizer Bypass Valve Hanger Bracket Assembly Vapor Manifold  2080006-001
Product Details:
Brand Name: GE
Model Number: 2080006-001
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,Paypal
Contact Now
Detailed Product Description
Manufacture: GE Material: Machined Aluminum Alloy
Condition: New Original Working Mec Gases: Medical Breathing Gas Mixture
Corlor: White Warranty: 90 Days
Lead Time: 3~5 Days Shape: Rectangular
Weight: Lightweight
Highlight:

Anesthesia Vaporizer Bypass Valve Hanger Bracket

,

Vapor Manifold Assembly 2080006-001

,

GE Datex-Ohmeda Vaporizer Mounting Bracket

GE Datex-Ohmeda Anesthesia Vaporizer Bypass Valve Hanger Bracket Assembly Vapor Manifold 2080006-001

 

Introduction

The GE 2080006-001 is a genuine vaporizer manifold assembly designed specifically for Datex-Ohmeda anesthesia machines. The assembly comprises a bypass valve that directs fresh gas either around or through the vaporizer, a mounting bracket that secures and locks the vaporizer in place, and a manifold body responsible for distributing gas into and out of the vaporizer.

 

This assembly serves as the central gas-flow control hub for the vaporizer mounting system. When the vaporizer is turned off, fresh gas flows directly through the bypass channel; when the vaporizer is turned on, the gas flow is diverted into the vaporization chamber to pick up  vapor before rejoining the bypass flow as it exits the manifold.

 

GE Datex-Ohmeda Anesthesia Vaporizer Bypass Valve Hanger Bracket Assembly Vapor Manifold  2080006-001

 

 

 

Replace Vaporizer Manifold 

 

 

GE Datex-Ohmeda Anesthesia Vaporizer Bypass Valve Hanger Bracket Assembly Vapor Manifold  2080006-001

 


1. Set system to Standby and remove the vaporizers.
2. Remove the upper rear panel, front flowmeter shield, and right side panel.
3. Remove the front screw at the right upright of the flowhead bezel.
4. From the back, remove the two screws holding the vertical support to the flowhead bracket.
5. Remove the two screws holding the vertical support to the vaporizer manifold.
6. Remove the vertical support.
7. Hold the manifold and remove the two screws at the right-hand extrusion to release it.
8. Attach the new manifold to the right-hand extrusion.
9. Attach the vertical support to the manifold, then to the flowhead bracket, then to the front bezel.
10. Leave all screws loose until all are in place. Tighten in order: E, D, C, B.
11. Reassemble the machine.
12. Perform leak test and checkout procedure per the service manual.

 

 

Usage Notes

 

Replacement work should only be performed by tralined biomedical service technicians. Inspect allintemal ports, threaded holes and sealing

surtaces for scratches. burs or dents before instalation.

 

Do not over-tighten screws. as thread damage or manifold distortion can be createdKeep all gas passages clean and free of dust, debris or residual ceaning uid This manifold is designed excusively for the specified

 

Datex- Ohmeda vaporizer models. Stop equipment operation at once f gas leakage or abnormal fow is detected arter installation

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: +8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.