logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Accessories

Draeger VISTA120 patient monitor mainstream CO2 sensor ETCO2 26062 REF 1015928 new

Draeger VISTA120 patient monitor mainstream CO2 sensor ETCO2 26062 REF 1015928 new

  • Draeger VISTA120 patient monitor mainstream CO2 sensor ETCO2 26062 REF 1015928 new
  • Draeger VISTA120 patient monitor mainstream CO2 sensor ETCO2 26062 REF 1015928 new
  • Draeger VISTA120 patient monitor mainstream CO2 sensor ETCO2 26062 REF 1015928 new
  • Draeger VISTA120 patient monitor mainstream CO2 sensor ETCO2 26062 REF 1015928 new
  • Draeger VISTA120 patient monitor mainstream CO2 sensor ETCO2 26062 REF 1015928 new
  • Draeger VISTA120 patient monitor mainstream CO2 sensor ETCO2 26062 REF 1015928 new
Draeger VISTA120 patient monitor mainstream CO2 sensor ETCO2 26062 REF 1015928 new
Product Details:
Brand Name: Drager
Model Number: REF 1015928
Payment & Shipping Terms:
Minimum Order Quantity: 1 box
Price: USD
Packaging Details: Standard Export Packing
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union, Paypal
Supply Ability: In stock
Contact Now
Detailed Product Description
Brand: Drager Product Name: Mainstream CO2 Sensor
Part Number: REF 1015928 Condition: New
Inventory: In Stock Payment Method: Paypal,T/T,Western Union
Delivery Method: DHL, FEDEX, UPS, Etc. Color: Grey
MOQ: 1pc Material: TPU Jacket
Key Word: ETCO2
Highlight:

Draeger VISTA120 mainstream CO2 sensor

,

ETCO2 26062 REF 1015928

,

Patient monitor CO2 sensor accessory

 

Draeger VISTA120 patient monitor mainstream CO2 sensor ETCO2 26062 REF 1015928 new

 

► Brief Description

 

Mainstream CO2 sensor ETCO2 26062 (REF 1015928); this is a compatible CO2 sensor designed for seamless compatibility with the Draeger VISTA120 patient monitor.This is a high-quality end-tidal CO₂ (EtCO₂) monitoring sensor designed for critical care, ICU, emergency department, and operating room environments, offering advanced respiratory monitoring capabilities. It not only enhances patient safety but also provides precise CO₂ waveform analysis, enabling continuous monitoring of respiratory status.This sensor enables real-time CO₂ measurement directly within the airway circuit, eliminating the need for sidestream sampling tubes; this reduces the risk of signal interruption caused by tube blockages or leaks while maintaining waveform response speed.

 

► Specifications

 

Brand Draeger
Part number REF 1015928
Product name mainstream CO2 sensor
MOQ 1pc
Warranty 90 Days
Payment Method T/T ,Paypal ,Western Union
Type Spare part
Delivery 3-5 Working Days
Use for Draeger VISTA120 patient monitor
Delivery Method DHL ,Fedex ,UPS
Stock Situation Stock available
Condition New
Color Grey

 

►Detailed Photos

 

Draeger VISTA120 patient monitor mainstream CO2 sensor ETCO2 26062 REF 1015928 new

 

►Functions of Mainstream Sensors

 

1.Utilizes Non-Dispersive Infrared (NDIR) technology to directly measure end-tidal CO2 (EtCO2), respiratory rate, and inspired CO2 concentration.

 

2.Assists in verifying tracheal tube placement, monitoring for ventilator circuit disconnection, and assessing the patient's respiratory status.

 

3.The sensor connects directly to the Y-piece of the breathing circuit, offering rapid response without the need for gas aspiration required by sidestream systems.

 

►Instructions for Use

 

1. After powering on and connecting the sensor, allow the module to warm up (approximately 2 minutes). Then, place the sensor in ambient indoor air and perform a "zero calibration" via the monitor's CO2 menu; connect the sensor to the patient only after calibration is complete.

 

2.The mainstream sensor is connected directly between the patient's artificial airway (e.g., endotracheal tube) and the breathing circuit.

 

3.Take care to prevent condensation from accumulating on the sensor window, as this may cause falsely elevated CO2 readings. Mainstream sensors typically utilize heating to minimize moisture condensation.

 

4.The monitor should display a square-wave CO2 waveform and show the ETCO2 value at the end of exhalation. If the reading is abnormal, check for secure connections, sensor malfunction, and the patient's clinical status.

 

Thank you for your time, if you are interested in Draeger VISTA120 patient monitor mainstream CO2 sensor ETCO2 26062 REF 1015928, please contact me immediately, I’ll reply you as soon as possible.

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Mia

Tel: 86-15779588554

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.