logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

Aeonmed Shangrila590P Ventilator Oxygen Sensor Model M-12 Hospital Ventilator Maintenance Spare Part

Aeonmed Shangrila590P Ventilator Oxygen Sensor Model M-12 Hospital Ventilator Maintenance Spare Part

  • Aeonmed Shangrila590P Ventilator Oxygen Sensor Model M-12 Hospital Ventilator Maintenance Spare Part
  • Aeonmed Shangrila590P Ventilator Oxygen Sensor Model M-12 Hospital Ventilator Maintenance Spare Part
  • Aeonmed Shangrila590P Ventilator Oxygen Sensor Model M-12 Hospital Ventilator Maintenance Spare Part
  • Aeonmed Shangrila590P Ventilator Oxygen Sensor Model M-12 Hospital Ventilator Maintenance Spare Part
  • Aeonmed Shangrila590P Ventilator Oxygen Sensor Model M-12 Hospital Ventilator Maintenance Spare Part
  • Aeonmed Shangrila590P Ventilator Oxygen Sensor Model M-12 Hospital Ventilator Maintenance Spare Part
Aeonmed Shangrila590P Ventilator Oxygen Sensor Model M-12 Hospital Ventilator Maintenance Spare Part
Product Details:
Brand Name: Aeonmed
Model Number: M-12
Payment & Shipping Terms:
Minimum Order Quantity: 1 Piece
Price: USD
Delivery Time: 3-5 working days
Payment Terms: T/T,Western Union,Paypal
Contact Now
Detailed Product Description
Product Name:: Oxygen Sensor Model:: M-12
Compatible Machine:: Shangrila590P Type:: Disposable
Condition:: New Original Package:: 1pc/box
Warranty:: 90 Days Color:: White
Shipping By:: DHL Delivery Time:: 7-10 Days
Highlight:

Shangrila590P Ventilator Oxygen Sensor

,

M-12 Ventilator Spare Part

,

Hospital Ventilator Maintenance Sensor

Aeonmed Shangrila590P Ventilator Oxygen Sensor Model M-12 Hospital Ventilator Maintenance Spare Part



 ► Brief Introduction
 

This product is a dedicated oxygen sensor for the Shangrila590P ventilator; it is a consumable spare part used to monitor oxygen concentration within the ventilator's gas circuit. The sensor comes in brand-new, sealed packaging; it is the M-12 model (Part No. 410517).

The upper section features a white ABS plastic housing printed with product details, such as the model and part number.

The lower section consists of the connection interface, equipped with a black O-ring seal, designed for a direct plug-in installation into the gas circuit.

 
 
► Features


1. Real-time Oxygen Level Monitoring

The sensing element within the oxygen sensor continuously measures the oxygen concentration in the ventilator's output circuit and transmits real-time signals to the ventilator's mainboard.

 

2. Ventilator Oxygen Output Control

The ventilator reads the oxygen concentration values ​​from the M-12 sensor and dynamically adjusts the valve to align the output concentration with clinical settings, ensuring effective ventilation therapy.

 

3. Anomaly Alerts and Alarms

If the actual oxygen concentration deviates from the set value beyond the permissible range, the change in sensor signal triggers an oxygen alarm, alerting maintenance personnel to check for faults in the gas supply or components.

 

4. Simple Plug-and-Play Replacement

The sensor features an integrated sealing O-ring and can be directly screwed or plugged into the ventilator's gas pathway chamber; it is ready for clinical use after oxygen calibration, making installation and maintenance convenient.



► Parameters
 

Product name

Oxygen Sensor

Model/PN

Model M-12

Compatible machine

Shangrila590P

Condition

New original

Weight

60g

Size

Small

MOQ

1 piece

Shipping by

DHL

Delivery time

7-10 days

 
 
► Product Picture
 

Aeonmed Shangrila590P Ventilator Oxygen Sensor Model M-12 Hospital Ventilator Maintenance Spare Part

Aeonmed Shangrila590P Ventilator Oxygen Sensor Model M-12 Hospital Ventilator Maintenance Spare Part


►FAQ
 

Q1: Can the M-12 oxygen sensor directly replace the older M-07 model?

A1: No, they are not interchangeable due to differences in physical design and connectors. The M-12 is specifically designed for the Shangrila 590P; please ensure you select and purchase the correct sensor based on the specific ventilator model.

 

Q2: Can the sensor be installed immediately after opening the original sealed metal packaging?

A2: It is recommended to let the sensor sit for 2–4 hours after opening to allow for full air exposure and activation before proceeding with installation and oxygen calibration.

 

Q3: How can I distinguish between an oxygen sensor fault and a circuit leak when the ventilator triggers intermittent oxygen alarms?

A3: First, perform a complete leak test to rule out any leaks in the breathing circuit; only after confirming there are no circuit leaks should you determine whether the M-12 oxygen sensor needs to be replaced.


Aeonmed Shangrila590P Ventilator Oxygen Sensor Model M-12 Hospital Ventilator Maintenance Spare Part Aeonmed Shangrila590P Ventilator Oxygen Sensor Model M-12 Hospital Ventilator Maintenance Spare Part
90 Day Warranty                             SGS ceryification

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Bella

Tel: 86-18879075074

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.