logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

Edan XM1 Model Parameter Board 21.53.451630-1.0 Excluding SpO2 Board Include Nibp Trachea

Edan XM1 Model Parameter Board 21.53.451630-1.0 Excluding SpO2 Board Include Nibp Trachea

  • Edan XM1 Model Parameter Board 21.53.451630-1.0 Excluding SpO2 Board Include Nibp Trachea
  • Edan XM1 Model Parameter Board 21.53.451630-1.0 Excluding SpO2 Board Include Nibp Trachea
  • Edan XM1 Model Parameter Board 21.53.451630-1.0 Excluding SpO2 Board Include Nibp Trachea
  • Edan XM1 Model Parameter Board 21.53.451630-1.0 Excluding SpO2 Board Include Nibp Trachea
  • Edan XM1 Model Parameter Board 21.53.451630-1.0 Excluding SpO2 Board Include Nibp Trachea
  • Edan XM1 Model Parameter Board 21.53.451630-1.0 Excluding SpO2 Board Include Nibp Trachea
Edan XM1 Model Parameter Board 21.53.451630-1.0 Excluding SpO2 Board Include Nibp Trachea
Product Details:
Brand Name: Edan
Model Number: XM1
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,Paypal
Contact Now
Detailed Product Description
Product Name: Edan XM1 Module Parameter Board Material: Plastic
ECG: 3/5-lead Acquisition Color: Green
NIBP: 0–300 MmHg Range Condition: Good
PCB Construction: Double-layer Medical-grade PCB Warranty: 90 Days
Payment: T/T, Western Union,Paypal
Highlight:

Edan XM1 parameter board

,

patient monitor trachea board

,

NIBP board for monitors

 

Edan XM1 Model Parameter Board 21.53.451630-1.0 Excluding SpO2 Board Include Nibp Trachea

 

Introduction

 

The Edan XM1 parameter board (material number 21.53.451630-1.0) is the core signal acquisition hardware for the XM1 plug-in module, which itself is a compact, slide-in expansion unit for the Edan Elite V5, V6, and V8 patient monitors. This particular board version is supplied without the SpO₂ sub-board, but it includes the complete NIBP pneumatic assembly—pump, valve, pressure sensor, and the trachea tubing—making it a complete solution for basic vital signs monitoring where pulse oximetry is either already provided elsewhere or not required.

 

Edan XM1 Model Parameter Board 21.53.451630-1.0 Excluding SpO2 Board Include Nibp Trachea

 

Functions

 

  • Handles the core vital signs. This board integrates the acquisition circuits for 3/5-lead ECG, respiration, dual-channel temperature, and NIBP on a single piece of hardware. The ECG front end uses a 24 bit ADC and achieves a common-mode rejection ratio of 135 dB, with multi stage filtering for muscle artifact and mains interference.

 

  • Includes the complete NIBP air circuit. The board carries the full pneumatic assembly: the micro pump, solenoid valve, pressure sensor, and the silicone trachea tubing. The pressure measurement range covers 0–300 mmHg with an accuracy of ±3 mmHg, and the system supports adult, pediatric, and neonatal inflation profiles fast inflation for adults, slower for smaller patients.

 

  • The tubing is medical-grade silicone that resists alcohol and disinfectant wipes without hardening or cracking. A built-in relief valve vents pressure instantly if the tubing is kinked or the cuff is over-tightened, preventing limb compression injury.

Parameter

 

 

Product Name

 

Edan XM1 Module Parameter Board

 

Compatible Host Monitors

 

Edan Elite V5 / V6 / V8 Patient Monitors

 

Included Components

 

NIBP pneumatic assembly (pump & trachea included)

 

ECG

 

3/5-lead, CMRR ≥ 135 dB

 

Respiration

 

Impedance-based, acquired via ECG electrodes

 

NIBP

 

Oscillometric, range 0–300 mmHg, accuracy ±3 mmHg

 

Temperature

 

Dual-channel (T1 / T2)

 

ADC

 

24-bit high-precision analog to digital converter

 

Installation Method

 

1. Position the replacement board onto the inner frame, aligning the mounting holes.

2. Secure with the original screws—do not overtighten.

3. Reconnect the NIBP tubing to the interface port.

4. Reconnect the ribbon cable to the board.

5. Reassemble the module housing, checking that no tubing or cable is pinched between the halves.

6. Slide the module back into the monitor rack until it locks.

7. Power on and run an NIBP leak test before returning the module to clinical use.

 

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: +8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.