logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsUsed Ultrasound Transducer

Original PHiliph C8-4V Endocavity Ultrasound Probe, Convex Array Curved Array Transducer

Original PHiliph C8-4V Endocavity Ultrasound Probe, Convex Array Curved Array Transducer

  • Original PHiliph C8-4V Endocavity Ultrasound Probe, Convex Array Curved Array Transducer
  • Original PHiliph C8-4V Endocavity Ultrasound Probe, Convex Array Curved Array Transducer
  • Original PHiliph C8-4V Endocavity Ultrasound Probe, Convex Array Curved Array Transducer
  • Original PHiliph C8-4V Endocavity Ultrasound Probe, Convex Array Curved Array Transducer
  • Original PHiliph C8-4V Endocavity Ultrasound Probe, Convex Array Curved Array Transducer
Original PHiliph C8-4V Endocavity Ultrasound Probe, Convex Array Curved Array Transducer
Product Details:
Place of Origin: USA
Brand Name: PHiliph
Certification: CE
Model Number: C8-4V
Payment & Shipping Terms:
Minimum Order Quantity: 1 Piece
Price: USD
Packaging Details: Standard Export Packing
Delivery Time: 3-5 working days
Payment Terms: T/T,Western Union,Paypal
Contact Now
Detailed Product Description
Product Category: Ultrasound Product Name: Probe / Transducer
Model: C8-4V Probe Type: Convex Array
Warranty: 90 Days Delivery Date: 3 - 5 Working Days
MOQ: One Piece Purchase Type: Outright
Price: Accept Negotiation Quality: High
Applicable Environment: Hospitals, Clinics, ICU, Etc. Condition: 100% Original
Highlight:

Original Philips C8-4V endocavity probe

,

Convex array ultrasound transducer

,

Curved array transducer with warranty

PHiliph C8-4V Probe

Original PHiliph C8-4V Endocavity Ultrasound Probe, Convex Array Curved Array Transducer


► Brief Description

The PHiliph C8-4v intracavitary ultrasound probe is a high-performance, broadband convex array ultrasound probe designed to meet diverse clinical diagnostic needs. This probe integrates seamlessly with compatible PHiliph ultrasound systems, providing excellent near-field resolution while ensuring deep tissue penetration, making it an indispensable precision diagnostic tool for clinicians.

Ultrasound probes are delicate and fragile components, requiring extra care in daily handling. Always turn off the main unit power before connecting or removing the probe. When plugging or unplugging, hold the plug body gently and insert or remove it gently; never pull the cable directly to avoid breaking internal wiring. Avoid collisions between the probe and hard objects during use. When not in use, store it properly in a dedicated probe holder or protective case; never hang it or allow the probe head to dangle freely.



► Specification

Technology Curved Array
Probe Type Intracavitary
Frequency Range 4-8 MHz.
Field of View 135 degree
Connector Large
Center Frequency 6 MHz.



► Detailed Photos

Original PHiliph C8-4V Endocavity Ultrasound Probe, Convex Array Curved Array Transducer



► Advantages 

  1. The core advantage of the C8-4V probe lies in its wide frequency range of 4-8 MHz, with a center frequency of 6 MHz¹. This allows physicians to dynamically adjust imaging parameters according to different diagnostic needs.

  2. This probe possesses excellent lateral and axial resolution, achieving a high resolution of ≤1 mm within a depth range of ≤40 mm, while strictly controlling the blind zone to ≤5 mm, ensuring clear visualization of superficial structures and effectively avoiding artifact interference.

  3. Furthermore, its geometrical positional accuracy is extremely high, with a lateral error of ≤10% and a longitudinal error of ≤5%, providing reliable spatial measurement assurance for clinical diagnosis.



► Clinical Applications

  • Obstetrics and Gynecology: Suitable for comprehensive fetal/obstetric assessments, gynecological examinations, and transvaginal ultrasound. Under transvaginal ultrasound, this probe is unaffected by intestinal gas, abdominal wall thickening, or bladder fullness, allowing clear observation of uterine morphology, endometrial thickness, and abnormal uterine cavity echoes. It is a highly efficient screening tool for diagnosing uterine cavity lesions such as endometrial polyps.

  • Urology: Performs excellently in transrectal prostate imaging and routine urological diagnosis.

  • Fetal Cardiac: Enables detailed imaging of the fetal heart, aiding in the early detection of congenital abnormalities.



► Cleaning

Proper cleaning and disinfection are crucial for extending probe lifespan and preventing cross-infection. After each use, immediately remove coupling agent and residue from the probe surface.

  1. Cleaning Agent Selection: A mild, near-neutral detergent, 75% ethanol, or 70% isopropanol is recommended for surface wiping. Strong solvents such as and Freon are strictly prohibited as they may corrode the probe housing or acoustic lens
  2. Disinfection Method: For intracavitary probes that come into contact with mucous membranes, medium to high-level disinfection is required. Immersion time must strictly adhere to the minimum time recommended by the disinfectant manufacturer (e.g., 12 minutes for Cidex OPA). Do not exceed the recommended immersion time.
  3. Critical Protection: The probe's deflection mechanism (control cover), cables, and connectors must not be immersed or rinsed to prevent liquid penetration and corrosion of internal gears and electrical connections. After disinfection, rinse thoroughly with sterile water and dry with a soft cloth or allow to air dry.





Thanks for your interest in Original PHiliph C8-4V Endocavity Ultrasound Probe, Convex Array Curved Array Transducer, please feel free to contact me. Thank you for your time and wish you have a happy life.

Original PHiliph C8-4V Endocavity Ultrasound Probe, Convex Array Curved Array Transducer Original PHiliph C8-4V Endocavity Ultrasound Probe, Convex Array Curved Array Transducer
90 Day Warranty                             SGS ceryification

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Jasmine

Tel: 86-15180047496

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.