logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

Medical Ultrasound Transducer Original Probe VF13-5 Linear Ultrasound Probe for Hospital Equipment

Medical Ultrasound Transducer Original Probe VF13-5 Linear Ultrasound Probe for Hospital Equipment

  • Medical Ultrasound Transducer Original Probe VF13-5 Linear Ultrasound Probe for Hospital Equipment
  • Medical Ultrasound Transducer Original Probe VF13-5 Linear Ultrasound Probe for Hospital Equipment
  • Medical Ultrasound Transducer Original Probe VF13-5 Linear Ultrasound Probe for Hospital Equipment
  • Medical Ultrasound Transducer Original Probe VF13-5 Linear Ultrasound Probe for Hospital Equipment
  • Medical Ultrasound Transducer Original Probe VF13-5 Linear Ultrasound Probe for Hospital Equipment
Medical Ultrasound Transducer Original Probe VF13-5 Linear Ultrasound Probe for Hospital Equipment
Product Details:
Model Number: VF13-5
Payment & Shipping Terms:
Minimum Order Quantity: 1 Piece
Price: USD
Delivery Time: 3-5 working days
Payment Terms: T/T,Western Union,Paypal
Contact Now
Detailed Product Description
Product Name:: Ultrasound Probe Model:: VF10-5
Material:: Plastic+Metal Array Type:: Linear
Condition:: Used-original Warranty:: 90 Days
Weight:: 1.8kg Size:: Small
Shipping By:: DHL Delivery Time:: 7-10 Days
Highlight:

VF13-5 linear ultrasound probe

,

medical ultrasound transducer probe

,

hospital equipment ultrasound transducer

Medical Ultrasound Transducer Original Probe VF13-5 Linear Ultrasound Probe for Acuson

 

 
 
► Brief Introduction
 

This is the VF12-5 linear array ultrasound probe, designed for compatibility with various models in the Acuson X series. It is a plug-and-play device that requires no calibration and is easy to use.

Operating at a frequency range of 5–12 MHz, this probe is primarily used for scanning superficial tissues.

The probe housing is constructed from high-strength plastic. Its shielded cable is highly durable and designed to minimize external signal interference, ensuring stable and reliable signal transmission when connected to the main unit.

 
 
► Features


1. High-Resolution Superficial Imaging

High-frequency imaging capabilities allow for the capture of detailed tissue structures in superficial areas such as the thyroid, breast, subcutaneous soft tissue, peripheral vessels, muscles, and nerves.

 

2. Blood Flow Visualization

Supports color flow imaging, enabling direct visualization of blood flow distribution at the contact surface and assisting in the assessment of vascular abnormalities.

 

3. Flexible Multi-Frequency Adjustment

Allows for switching between operating frequencies to balance scanning depth and image clarity as needed, accommodating various superficial examination requirements.

 

4. Rapid System Recognition

When connected to a compatible color ultrasound unit, the system automatically recognizes the probe and quickly loads the corresponding examination presets.


► Parameters
 

Product name

Color Doppler Ultrasound

Model/PN

VF13-5

Condition

Used but good condition

Warranty

90-day

Frequency range

5-13Mhz

Type

Linear

Weight

1.8KG

Shipping time

7-10 days

Lead time

3-5 working days

Payment by

Paypal, Bank transfer, Western Union

 
 
► Product Picture
 

Medical Ultrasound Transducer Original Probe VF13-5 Linear Ultrasound Probe for Hospital EquipmentMedical Ultrasound Transducer Original Probe VF13-5 Linear Ultrasound Probe for Hospital EquipmentMedical Ultrasound Transducer Original Probe VF13-5 Linear Ultrasound Probe for Hospital Equipment



►FAQ
 

Q1: Can this VF13-5 probe directly replace a linear array probe of the same frequency from another brand?

A1: No. The probe connector and internal communication protocols are incompatible; it supports only designated host models and will not be recognized by equipment from other brands.

 

Q2: Can the probe still be used if there are minor scratches on the acoustic head surface?

A2: If the scratches are merely superficial and there is no fluid leakage, you can connect it to the system to test the image quality. However, if the protective layer cracks or leakage occurs, stop using it immediately to prevent damage to the ultrasound unit.

 

Q3: When purchasing a second-hand probe, what is the first test to perform upon arrival to verify its condition?

A3: First, connect it to the compatible host unit to ensure the probe is recognized correctly. Check the superficial image for any dark spots or artifacts, and verify that the blood flow imaging function is operating normally.


Medical Ultrasound Transducer Original Probe VF13-5 Linear Ultrasound Probe for Hospital Equipment Medical Ultrasound Transducer Original Probe VF13-5 Linear Ultrasound Probe for Hospital Equipment
90 Day Warranty                             SGS ceryification

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Bella

Tel: 86-18879075074

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.