| Brand Name: | Mindray |
| Model Number: | 115-021461-00 115-015343-00 |
| Minimum Order Quantity: | 1 |
|---|---|
| Delivery Time: | 3-5 working days |
| Payment Terms: | T/T, Western Union,Paypal |
| Part Number: | 115-021461-00; 115-015343-00 | Compatible Ventilators: | Mindray SV , E Series |
|---|---|---|---|
| Product Type: | Expiration / Exhalation Valve Assembly | Key Feature: | PEEP Control |
| Material: | Plastic | Charge Time: | Approximately 2.5 Hours |
| Condition: | New Original | Sterilization: | Up To 121°C |
| Warranty: | 90 Days | Payment: | T/T, Western Union,Paypal |
| Highlight: | Mindray disinfectable expiratory valve,expiratory valve assembly for patient monitors,Mindray 115-021461-00 valve with warranty |
||
Mindray Disinfectable Expiratory Valve Assembly 115-021461-00 115-015343-00
Introduction
The Mindray 115-021461-00 (and its related component 115-015343-00) is a sterilizable expiratory valve assembly, an original equipment manufacturer (OEM) component for Mindray ventilators. This assembly controls the flow rate of exhaled gases during mechanical ventilation.
The assembly includes a valve body, a medical-grade silicone diaphragm, and a seal. It is installed at the ventilator's expiratory port to control the release of exhaled gases to maintain the pressure and volume set by the clinician. This assembly is compatible with Mindray SV and E series ventilators.
![]()
Expiration Valve
![]()
A. Expiration valve assembly
B. Expiration valve handwheel
C. Expiration valve membrane
D. Locked state of the expiration valve
E. Unlocked state of the expiration valve
Functions
1. Controls the flow of exhaled gas. The expiratory valve assembly is the active element that regulates the release of exhaled gases from the patient's breathing circuit. It ensures that the ventilator can accurately maintain the user-set pressure levels throughout the respiratory cycle.
2. Maintains stable PEEP. The medical-grade silicone diaphragm responds swiftly to pressure changes, ensuring stable Positive End Expiratory Pressure control. This is essential for keeping the alveoli open and improving oxygenation in critically ill patients.
3. Provides accurate flow and volume monitoring. The valve assembly supports expiratory flow and volume monitoring. This data is fed back to the ventilator's control system, enabling it to adjust therapy in real time and ensuring the patient receives the prescribed tidal volume.