| Product Name: | Patient Monitor | Model: | Vigilance II |
|---|---|---|---|
| Resolution: | 1280 × 800 | Display: | Color TFT Screen |
| AC Voltage: | 100 V To 240 V~ | Condition: | Used With Good Condition |
| Color: | White | Warranty: | 90 Days |
| Delivery Date: | 3 - 5 Working Days | MOQ: | One Piece |
| Purchase Type: | Outright | Price: | Accept Negotiation |
| Quality: | High | Applicable Environment: | Hospitals, Clinics, ICU, Etc. |
| Highlight: | Edwards Lifesciences Vigilance II monitor,bedside patient monitoring device,used medical monitor with warranty |
||
Edwards Lifesciences Vigilance II Monitor
Edwards Lifesciences Vigilance II Patient Monitor, Bedside Medical Monitoring Device
► Brief Description
The Edwards Lifesciences Vigilance II Monitor is a crucial medical device capable of continuously monitoring multiple key physiological parameters. It is suitable for use in hospitals, clinics, emergency rooms, and during patient transport. The Vigilance II monitoring system consists of three main components: the main unit (VIG2E), the optical module (OM2E), and the patient cable (70CC2).
The core function of the Edwards Lifesciences Vigilance II system is its use of transpulmonary thermodilution minimally invasive monitoring technology to continuously monitor multiple key physiological parameters and display important physiological indicators, providing comprehensive blood flow and tissue oxygenation data to support accurate patient management.
► Major Parts and Keys
![]()
► Parameter Monitoring
► Oximetry Setup & Calibration
1. Connect the optical module to the color-coded 5vO2/ScvO2 connector on the front of the monitor. Connect the catheter to the optical module, ensuring the "top" is facing upwards. Allow the module to warm up for 20 minutes.
2. Use the navigation knob to select the SvO2/ScvO2 large parameter box. Press the knob to display the calibration menu. Select "In Vitro Calibration". Press the knob to select.
3. Select "Hemoglobin (HGB)". Press the knob to select. Rotate the knob to enter the hospital laboratory value. Press the knob to confirm the setting.
4. Rotate the knob to select "Calibrate". Press the knob to select. After successful calibration, insert the catheter into the patient.
5. Select "Start". Press the knob to select.
1. Use the navigation knob to select the SvOz/5cvOz large parameter box. Press the knob to display the calibration menu.
2. Select "In Vivo Calibration". Press the knob to select.
3. After 25 seconds, the "Draw Blood" option will be selected. Press the knob before drawing waste and laboratory samples.
4. Use the knob to enter the blood oxygen saturation and hemoglobin (HGB) or hematocrit (Hct) values.
5. Select "Calibration". Press the knob to select.
► Features
|
1. Easy to operate: Enables simple acquisition of complex hemodynamic data, suitable for rapid bedside diagnosis and treatment. |
| 2. Customizable interface: All monitoring and export parameters can be displayed in a customizable window for clinicians, with customizable trend graphs, data relationships, and status displayed on the screen. |
| 3. Compatible with other systems: This system can be used in conjunction with the Swan-Ganz pulmonary artery catheter or the Edwards oxygenation catheter. |