Replacement Ventilator Gas Filter PN 15571400 for G5 Hamil-ton

Replacement Ventilator Gas Filter PN 15571400 for G5 Hamil-ton

  • Replacement Ventilator Gas Filter PN 15571400 for G5 Hamil-ton
  • Replacement Ventilator Gas Filter PN 15571400 for G5 Hamil-ton
  • Replacement Ventilator Gas Filter PN 15571400 for G5 Hamil-ton
  • Replacement Ventilator Gas Filter PN 15571400 for G5 Hamil-ton
  • Replacement Ventilator Gas Filter PN 15571400 for G5 Hamil-ton
  • Replacement Ventilator Gas Filter PN 15571400 for G5 Hamil-ton
Replacement Ventilator Gas Filter PN 15571400 for G5 Hamil-ton
Product Details:
Brand Name: Hamil-ton
Model Number: 15571400
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,Paypal
Contact Now
Detailed Product Description
Part Number: 15571400 Filter Type: Single-use
Tubing Length: 1.88 M Flow Range: 0 – 180 L/min
Resistance: < 2.5 CmH₂O At 50 L/min Connectors: 15mm / 22mm
Seal: Latex-free Shelf Life: 2 Years
Warranty: 90 Days Certifications: ISO 13485

Replacement Ventilator Gas Filter PN 15571400 for G5 Hamil-ton

 

Brief introduction

 

The Hamil-ton Medical 15571400 is an original, single-use, high-efficiency hydrophobic gas filter designed specifically for the HAMIL-TON-G5 ventilators. It's a critical consumable that sits at the inspiratory and expiratory ports of the ventilator, purifying the gas that flows to and from the patient.

 

Built with a pleated hydrophobic membrane and electrostatic technology, the filter offers a large filtration area with low airflow resistance. Under ventilation pressure, it provides a 100% seal against liquids and aerosols, effectively blocking condensation and contaminants from entering the device's internal gas pathways. It's a key barrier against cross-contamination, protecting both the patient and the ventilator's internal components.

 

Replacement Ventilator Gas Filter PN 15571400 for G5 Hamil-ton

 

 

Parameter

 

Filter Type

Single-use, high-efficiency hydrophobic gas filter

Filtration Technology

Pleated hydrophobic membrane + electrostatic composite

Filtration Efficiency

≥99.995% for bacteria (0.5–5μm) and particles; ≥99.995% for viruses (≥0.02μm)

Flow Range

0 – 180 L/min

Resistance

< 2.5 cmH₂O at 50 L/min

Connectors

15mm / 22mm standard tapered connectors

 

 

Functions

 

1. This filter removes contaminants from breathing gases with an efficiency of ≥99.995%. This protects patients from airborne pathogens and prevents the spread of multidrug-resistant bacteria and respiratory pathogens through the ventilator circuit. It also prevents contaminants from flowing back into the ventilator, protecting internal components and reducing the risk of cross-infection between patients.

 

2. Maintaining low resistance ensures accurate ventilation. Despite its high filtration efficiency, the filter's pleated design keeps its resistance low—less than 2.5 cmH₂O at a flow rate of 50 L/min. This minimizes the impact on ventilation accuracy and ensures uninterrupted breathing for the patient. A flow rate range of 0–180 L/min makes it suitable for adults, children, and newborns.

 

3. Effectively blocks liquids and aerosols. This hydrophobic membrane is effectively waterproof and 100% seals against liquids and aerosols at ventilation pressure. This prevents condensation and secretions from entering the ventilator's gas path, protecting the device from damage.

 

Pay attention 

 

  • Replace the filter regularly. The recommended replacement interval is every 7 to 30 days, depending on the clinical environment and the level of contamination. Frequent replacement helps maintain filtration efficiency and reduces the risk of VAP.
  • Monitor for increased resistance. Expiratory filters can become clogged over time with humidity and particles from nebulised medications. If resistance builds up, it can impair ventilation and may trigger an Exhalation obstructed alarm on the G5 ventilator. Regularly check the expiratory flow rate and the expiratory time constant (RCexp) for signs of increasing resistance.
  • Do not reuse the filter. The 15571400 is a single-use, single-patient filter.

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: +8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.