logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

Drager 8606055-07 Right Side O2 Sensor Housing New Original Condition for Hospital Device

Drager 8606055-07 Right Side O2 Sensor Housing New Original Condition for Hospital Device

  • Drager 8606055-07 Right Side O2 Sensor Housing New Original Condition for Hospital Device
  • Drager 8606055-07 Right Side O2 Sensor Housing New Original Condition for Hospital Device
  • Drager 8606055-07 Right Side O2 Sensor Housing New Original Condition for Hospital Device
  • Drager 8606055-07 Right Side O2 Sensor Housing New Original Condition for Hospital Device
  • Drager 8606055-07 Right Side O2 Sensor Housing New Original Condition for Hospital Device
  • Drager 8606055-07 Right Side O2 Sensor Housing New Original Condition for Hospital Device
Drager 8606055-07 Right Side O2 Sensor Housing New Original Condition for Hospital Device
Product Details:
Brand Name: Drager
Model Number: 8606055-07
Payment & Shipping Terms:
Minimum Order Quantity: 1 Piece
Price: USD
Delivery Time: 3-5 working days
Payment Terms: T/T,Western Union,Paypal
Contact Now
Detailed Product Description
Product Name:: O2 Sensor Housing Model:: 8606055-07
Weight:: About 60g/pc Material:: Plastic Shell
Condition:: New Original Package:: 1pc/box
Warranty:: 90 Days Red:: Black
Shipping By:: DHL Delivery Time:: 7-10 Days
Highlight:

Drager O2 sensor housing

,

hospital device sensor housing

,

patient monitor O2 sensor

Drager 8606055-07 Right Side O2 Sensor Housing New Original Condition for Hospital Device

 
 
► Brief Introduction
 

This is the oxygen sensor assembly in the right side airway of the ventilator, part number 8606055-07. It is a separately packaged replacement part, including the sensor housing, transmission cable, and connector. This component serves multiple purposes, primarily securing the oxygen sensor and collecting airway oxygen concentration signals; it is a key component for monitoring inhaled oxygen concentration.

 

This is the right-side oxygen sensor assembly. A corresponding left-side oxygen sensor assembly also exists. The connectors and installation methods for the two are not interchangeable.

 
 
Features


1. Immobilized Oxygen Cell

The internal cavity of the housing forms a sealed sampling space, ensuring a smooth airflow over the oxygen cell surface and guaranteeing stable and accurate oxygen concentration data.

 

2. Transmission of Oxygen Concentration Signal

The cable stably transmits the concentration signal collected by the oxygen cell to the main unit. The ventilator relies on this data to display and adjust the output oxygen concentration in real time.

 

3. Isolation of Oxygen Sensor from Moisture

The sealed housing structure prevents condensation in the breathing circuit from directly soaking the oxygen cell and plug contacts, reducing rapid battery failure and interface corrosion.

 

4. Physically Separating the Air Pathway

The dedicated shape on the right side prevents interchangeability with the oxygen sensor assembly on the left, avoiding misalignment of the airway sampling and causing abnormal oxygen concentration measurement alarms.

 

5. Vibration Buffering

When the equipment moves or vibrates during operation, the housing firmly holds the oxygen cell, preventing it from loosening and making poor contact, eliminating abrupt changes in oxygen concentration values, and ensuring the accuracy of the monitoring process.



► Parameters
 

Product name

O2 Sensor Housing

Part number

8606055-07

Machine model

Babylog VN500 Ventilator

Condition

New original

Shipping by

Air or Express

Color

Black

MOQ

1pc

Lead time

3-5 working days

Package

Carton

Shipping by

DHL,by air

 
 
► Product Picture
 

Drager 8606055-07 Right Side O2 Sensor Housing New Original Condition for Hospital Device
Drager 8606055-07 Right Side O2 Sensor Housing New Original Condition for Hospital Device
 


►FAQ
 

Q1: The cable sheath has minor scratches, but the inner core is not broken. Can it still be used on the machine?

A1: It can be used temporarily as an emergency measure, but long-term use is not recommended. Daily bending and pulling of the equipment will accelerate damage, easily causing intermittent signal loss and resulting in oxygen concentration monitoring failure.

 

Q2: There are slight differences in cable length between different batches of the 8606055-07 assembly. Will this affect the performance?

A2: Minor length tolerances in compliant batches from the original manufacturer do not affect signal acquisition. As long as the model is consistent, it will be compatible with the ventilator.

 

Q3: The ventilator occasionally intermittently indicates an oxygen sensor malfunction, sometimes working and sometimes not. Is it more likely a problem with the oxygen battery or the housing assembly?

A3: First check the housing plug contacts for moisture and oxidation, and for hidden breaks inside the cable. Intermittent malfunctions mostly originate from the wiring and connectors, not simply a problem with the oxygen battery.



Drager 8606055-07 Right Side O2 Sensor Housing New Original Condition for Hospital Device Drager 8606055-07 Right Side O2 Sensor Housing New Original Condition for Hospital Device
90 Day Warranty                             SGS ceryification

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Bella

Tel: 86-18879075074

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.