logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

Covidien PB840 Ventilator PSOL Valve 4-071800-00 Spare Part Used in Good Working

Covidien PB840 Ventilator PSOL Valve 4-071800-00 Spare Part Used in Good Working

  • Covidien PB840 Ventilator PSOL Valve 4-071800-00 Spare Part Used in Good Working
  • Covidien PB840 Ventilator PSOL Valve 4-071800-00 Spare Part Used in Good Working
  • Covidien PB840 Ventilator PSOL Valve 4-071800-00 Spare Part Used in Good Working
  • Covidien PB840 Ventilator PSOL Valve 4-071800-00 Spare Part Used in Good Working
  • Covidien PB840 Ventilator PSOL Valve 4-071800-00 Spare Part Used in Good Working
  • Covidien PB840 Ventilator PSOL Valve 4-071800-00 Spare Part Used in Good Working
Covidien PB840 Ventilator PSOL Valve 4-071800-00 Spare Part Used in Good Working
Product Details:
Brand Name: Covidien
Model Number: 4-071800-00
Payment & Shipping Terms:
Minimum Order Quantity: 1 Piece
Price: USD
Packaging Details: Standard Export Packing
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union, Paypal
Supply Ability: In stock
Contact Now
Detailed Product Description
Brand: Covidien Product Name: PSOL Valve
Model: 4-071800-00 MOQ: 1 Piece
Warranty: 90 Days Condition: Used Original
Inventory: In Stock Payment Method: Paypal,T/T,Western Union
Delivery Method: DHL, FEDEX, UPS, Etc. Color: Grey
Highlight:

Covidien PB840 ventilator PSOL valve

,

PB840 ventilator spare part

,

ventilator PSOL valve with warranty

Covidien PB840 Ventilator PSOL Valve 4-071800-00 Spare Part 

 

 

► Brief Description

 

The Covidien PB840 ventilator PSOL valve (part number 4-071800-00) is primarily constructed from metal, featuring an exterior with high corrosion and oxidation resistance. It utilizes a built-in linear motor to control the poppet valve. After undergoing filtration and pressure regulation, compressed air and oxygen enter PSOL2 and PSOL1, respectively; the mainboard employs closed-loop control to precisely mix the gases according to the set inspired oxygen fraction (FiO₂) and tidal volume, delivering the mixture to the patient circuit. The valve's control precision directly determines the accuracy of oxygen concentration and ventilation volume—with an error margin typically ≤±2%—thereby meeting clinical requirements for patients ranging from adults and children to neonates. This valve serves as the "heart" of the gas delivery control system in the Covidien PB840 ventilator, utilizing precision electromagnetic proportional control technology to achieve accurate regulation of the air-oxygen mixture's flow rate and concentration.

 

► Specifications

 

Brand Covidien
Model 4-071800-00
Product name PSOL Valve
MOQ 1 piece
Warranty 90 Days
Payment Method T/T ,Paypal ,Western Union
Product Edge Original,Advanced equipment
Delivery 3-5 Working Days
Use for Covidien PB840 Ventilator
Payment Terms Full Before Shippment
Delivery Method DHL ,Fedex ,UPS
Stock Situation Stock available
Material Metal

 

►Detailed Photos

 

Covidien PB840 Ventilator PSOL Valve 4-071800-00 Spare Part Used in Good Working

 

►Installation Steps

 

1. Preparation and Inspection: Ensure that all O-rings on the new PSOL valve assembly are intact and correctly positioned.

 

2. Align Components: Align the air and oxygen ports on the PSOL valve assembly with the corresponding ports on the regulator assembly.

 

3. Press-fit Assembly: Gently press the PSOL valve assembly against the regulator assembly until it contacts the stop posts. Note: It may be necessary to gently flex the inspiratory baseplate downward during installation to ensure the components seat correctly.

 

4. Secure Screws: Install and tighten the two screws securing the valve assembly to the baseplate; tighten until snug, but do not overtighten.

 

5. Reassembly and Testing: Reinstall the left and right side panels. After installation, be sure to perform the EST (Extended Self-Test) and calibration procedures to verify that the new valve's performance meets requirements.

 

►Common Faults

 

As a critical, wear-prone component of the ventilator, the PSOL valve may experience the following issues during prolonged use:

 

1.Wear of internal seals

 

2.Aging of the electromagnetic coil

 

3.Clogging due to gas impurities

 

These faults can lead to oxygen concentration drift, flow inaccuracies, or system alarms.

 

If you want to replace the PSOL Valve 4-071800-00 for Covidien PB840 Ventilator, please send an inquiry to me, I’ll give you a quote immedicately.Looking forward to hearing from you.

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Mia

Tel: 86-15779588554

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.