logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsUsed Patient Monitor

Contec CMS4100 Ambulatory EEG Monitor Portable 24 Hours Recorder

Contec CMS4100 Ambulatory EEG Monitor Portable 24 Hours Recorder

  • Contec CMS4100 Ambulatory EEG Monitor Portable 24 Hours  Recorder
  • Contec CMS4100 Ambulatory EEG Monitor Portable 24 Hours  Recorder
  • Contec CMS4100 Ambulatory EEG Monitor Portable 24 Hours  Recorder
  • Contec CMS4100 Ambulatory EEG Monitor Portable 24 Hours  Recorder
  • Contec CMS4100 Ambulatory EEG Monitor Portable 24 Hours  Recorder
Contec CMS4100 Ambulatory EEG Monitor Portable 24 Hours  Recorder
Product Details:
Brand Name: Contec
Model Number: CMS4100
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,Paypal
Contact Now
Detailed Product Description
Device Type: Ambulatory EEG System Model: CMS4100
Number Of Channels: 16 Channels Recording Medium: SD Card / T-Flash Memory Card
Recording Duration: Up To 24 Hours Technology: SMD
Input Impedance: ≥10MΩ Working Voltage: DC 3.7V~4.2V
A/D Transformation:: Max. 24 Bits Warranty: 90 Days
Highlight:

Contec CMS4100 EEG monitor portable

,

ambulatory EEG recorder 24 hours

,

used patient monitor with warranty

Contec CMS4100 Ambulatory EEG Monitor Portable 24 Hours Recorder

 

Product Introduction

 

The CONTEC CMS4100 is an ambulatory electroencephalograph (AEEG) a portable system designed to record brain activity over an extended period while the patient goes about their daily routine. It consists of two main parts: a compact, lightweight record box that the patient wears, and analysis software that runs on a computer.

 

The record box is small enough to be worn comfortably for 24 hours at a time, and it captures EEG signals from 16 channels simultaneously, storing the data on an SD card. The analysis software allows clinicians to review, edit, and interpret the recorded waveforms, and includes a full suite of automated analysis tools from spike detection to power spectrum analysis.

 

Contec CMS4100 Ambulatory EEG Monitor Portable 24 Hours  Recorder

 

Basic Performance Specifications

 

Parameter Specification
Channel Count 16 channels of EEG Holter
Calibrating Voltage Sine signal 50 µV / 5 mm; frequency: 10 Hz; error: ≤ ±5%
Input Impedance ≥ 10 MΩ
Sampling Rate Max. 250 dots / second / channel
A/D Transformation Max. 24 bits
Common Mode Rejection Ratio (CMRR) ≥ 90 dB
Working Voltage DC 3.7 V – 4.2 V
50 Hz Interference Suppression ≥ 30 dB
Patient Leakage Current < 10 µA
Noise Level ≤ 5 µVp-p

 

 

Functions

 

 

1. SMD integration Amplification, filtering, and A/D conversion are combined in a single compact unit for reliable, interference‑resistant recording.

 

2. 24 hours ambulatory recording Patients move freely while the device captures transient or concealed epileptiform activity that routine EEG may miss.

 

3. B&T sync sampling is supported; real‑time data upload and waveform monitoring are available as options.

 

4. Flexible playback amplitude and speed are adjustable, and lead montages (monopolar, bipolar, or custom) can be set freely.

 

5. Case comparison two different cases, or the same case at different times, can be viewed side by side.

 

6. EEG segment clipping any section of the waveform can be cut out for analysis, multiple segments can be automatically distilled into different parameter sets.

 

Before Use

  • Read the user manual carefully before first use.

  • Inspect the record box, cables, battery, and SD card for any visible damage.

  • Charge the battery fully and ensure the SD card has sufficient storage space.

  • Prepare the patient's scalp properly clean the skin and apply electrodes according to standard EEG procedures.

  • Instruct the patient to keep a diary of activities and symptoms during the recording.

​

Monitoring and Troubleshooting

  • Check the device indicator lights periodically to confirm it is recording properly.

  • If an electrode becomes loose or detached, reapply it as soon as possible.

  • If the device malfunctions, stop using it and contact your biomedical engineering department or authorised service provider.

  • Do not use the device during MRI scanning,remove the record box and electrodes before the patient enters the MRI suite.

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: +8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.