logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsUsed Patient Monitor

CONTEC CA20M Mainstream End Tidal CO2 Monitor Portable Capnography Device

CONTEC CA20M Mainstream End Tidal CO2 Monitor Portable Capnography Device

  • CONTEC CA20M Mainstream End Tidal CO2 Monitor Portable Capnography Device
  • CONTEC CA20M Mainstream End Tidal CO2 Monitor Portable Capnography Device
  • CONTEC CA20M Mainstream End Tidal CO2 Monitor Portable Capnography Device
  • CONTEC CA20M Mainstream End Tidal CO2 Monitor Portable Capnography Device
  • CONTEC CA20M Mainstream End Tidal CO2 Monitor Portable Capnography Device
  • CONTEC CA20M Mainstream End Tidal CO2 Monitor Portable Capnography Device
CONTEC CA20M Mainstream End Tidal CO2 Monitor Portable Capnography Device
Product Details:
Brand Name: Contec
Model Number: CA20M
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,Paypal
Contact Now
Detailed Product Description
Model: CONTEC C50 Measurement Method: Mainstream Capnography
Display: Handheld Unit With LCD Screen Power Supply: DC 3.7V Lithium Battery
Operating Temperature: 5°C – 40°C Operating Humidity: 30% – 75%
Atmospheric Pressure: 700 – 1060 HPa Sound Level: ≤ 55 DB(A)
Protection: IPX1
Highlight:

portable end tidal CO2 monitor

,

mainstream capnography device

,

used patient CO2 monitor

CONTEC CA20M Mainstream End Tidal EtCO2 Monitor Portable Capnography Device

 

Product Introduction

 

The CONTEC CA20M is a handheld capnograph that uses mainstream measurement technology to monitor end‑tidal carbon dioxide (EtCO₂) and airway respiration rate (AwRR) in real time. In addition to CO₂ monitoring, it also measures blood oxygen saturation (SpO₂) and pulse rate, making it a compact multi‑parameter device for respiratory and oxygenation assessment.

 

The monitor connects to the patient's airway via an airway adapter and breathing tube. It is designed for use in emergency departments, ICUs, operating rooms, respiratory wards, and other clinical settings. The device is suitable for adult, paediatric, and infant patients.

 

CONTEC CA20M Mainstream End Tidal CO2 Monitor Portable Capnography Device 0

Technical Specifications

 

EtCO₂ Measurement Range

0 – 150 mmHg

 

Resolution

1 mmHg

 

Accuracy (0 – 40 mmHg)

±2 mmHg

 

Accuracy (41 – 70 mmHg)

±5% of readings

 

Accuracy (71 – 100 mmHg)

±8% of readings

 

Accuracy (101 – 150 mmHg)

±10% of readings

 

Initiation Warm up Time

2 minutes

 

Response Time

< 3 seconds

 

Operating Time (Battery)

8 hours

 

Alarm Sound Pressure Level

50 dB

 

 

Functions:

 

1. Supports end-tidal carbon dioxide respiratory rate SpO2 and pulse rate detection
2. Three optional measuring units are available for parameter display
3. Equips visual and audible alert systems with mute control adjustable threshold values and over-limit reminders for EtCO2 respiration rate SpO2 and pulse readings
4. Delivers low battery notification and power disconnection alerts for the external power adapter
5. Allows user-initiated calibration and integrates atmospheric pressure plus temperature compensation algorithms
6. Liquid ingress protection grade reaches IPX1 the applied part meets BF defibrillation-resistant standard against hazards
7. Built in rechargeable lithium cell provides continuous operation up to 8 hours
8. Reserves modular space for data storage and signal transmission expansion

 

Notice

 

Use only the accessories supplied with the device. The airway adapter and SpO₂ probe are designed specifically for this monitor. Using non approved accessories may affect measurement accuracy or safety.

 

Handle the CO₂ sensor and cable with care. The sensor cable should not be folded or pulled excessively. Damage to the cable or sensor can affect measurement accuracy.

 

Keep the device and sensor clean. The monitor and its sensor probe should be cleaned and disinfected regularly using the disinfectant specified in the user manual. Always disconnect the device from power before cleaning.

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: +8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.