| Brand Name: | Contec |
| Model Number: | C50 |
| Minimum Order Quantity: | 1 |
|---|---|
| Delivery Time: | 3-5 working days |
| Payment Terms: | T/T, Western Union,Paypal |
| Model: | CONTEC C50 | Technology: | Pressure Swing Adsorption |
|---|---|---|---|
| Flow Rate: | 0.5 – 5 L/min | Oxygen Concentration: | 93% ± 3% |
| Outlet Pressure: | 20 – 50 KPa | Power Supply: | AC 220V ± 10% |
| Power Consumption: | ≤ 400 VA | Sound Level: | ≤ 55 DB(A) |
| Working Temperature: | +5 ºC~+40 ºC | Color: | White |
| Highlight: | Contec C50 portable oxygen concentrator,5L medical grade oxygen generator,portable oxygen concentrator with warranty |
||
Contec C50 5L Portable Oxygen Concentrator Medical Grade Generator
Product Introduction
The CONTEC C50 is a 5 litre portable medical oxygen concentrator, designed to provide a reliable supply of supplemental oxygen for patients with respiratory needs. It’s intended for use in a range of settings from hospitals and clinics to home care.
Inside the unit, a compressor draws in ambient air and passes it through a molecular sieve bed that uses pressure swing adsorption (PSA) technology to separate oxygen from nitrogen. The result is a steady stream of medical grade oxygen at concentrations of around 93%. The concentrator also includes a built in pulse oximeter that measures the patient’s SpO₂ and pulse rate in real time, allowing for continuous monitoring during therapy.
![]()
Specification
|
SpO₂ Measurement Range
|
35% – 100% |
|
SpO₂ Accuracy
|
±2% (75% – 100%) |
|
Pulse Rate Range
|
25 – 250 bpm |
|
Pulse Rate Accuracy
|
1% ± 1 bpm |
|
Operating Temperature
|
10°C – 40°C |
|
Operating Humidity
|
≤ 80% |
|
Atmospheric Pressure
|
860 – 1060 hPa |
|
Ingress Protection
|
IP21 |
|
Oxygen Concentration
|
93% ± 3% (at 0.5–5 L/min, after 30 minutes of operation) |
Advantages
1. Delivers therapeutic‑grade oxygen. The PSA system produces oxygen at a concentration of 93% ± 3%, which is well within the standard for medical‑grade oxygen therapy. The flow rate can be adjusted from 0.5 to 5 litres per minute, giving clinicians and patients the flexibility to match the prescribed dosage.
2. Monitors blood oxygen levels in real time. A built‑in pulse oximeter continuously measures SpO₂ and pulse rate. This means the patient’s oxygen saturation can be tracked throughout therapy without the need for a separate monitor.
3. Built for mobility and everyday use. The unit comes with castors (turning truckle) that make it easy to move from room to room. The compact footprint and manageable weight allow it to be positioned at the bedside or relocated as the patient’s needs change.
Precautions
Contact Person: Rita