China World Technology Medical Equipment Service Group
Win-win together!
| Brand Name: | Comen |
| Model Number: | CH8600CS |
| Minimum Order Quantity: | 1 Piece |
|---|---|
| Price: | USD |
| Delivery Time: | 3-5 working days |
| Payment Terms: | T/T,Western Union,Paypal |
| Product Name:: | Blood Cell Analyzer | Model:: | CH8600CS |
|---|---|---|---|
| Screen Size:: | 10.4 Inch | Weight:: | About 28KG |
| Condition:: | Used-good | Language:: | English/Chinese |
| Warranty:: | 90 Days | Reagent Storage Time:: | More Than 90 Days |
| Shipping By:: | DHL | PAYMENT TERMS:: | Pay In Full Before Shipment |
| Highlight: | Comen CH8600CS blood cell analyzer,automatic blood analyzer for hospital,clinical laboratory blood cell analyzer |
||
Excellent Medical Machine Comen CH8600CS Fully Automatic Blood Cell Analyzer for Hospital Clinical Laboratory
► Brief Introduction
This CH8600CS blood analyzer is a human five-part differential hematology analyzer. This benchtop hematology analyzer combines routine blood count (CBC) and CRP testing, and is commonly used in hospital laboratories, health check-up departments, and independent laboratories.
The device's casing is made of unibody medical-grade flame-retardant ABS plastic, a wear-resistant and corrosion-resistant material that can withstand prolonged wiping with alcohol/disinfectants. Reagent trays are located on both sides of the device, allowing for direct reagent placement and preventing the mixing of blood, diluents, and cleaning solutions. Independent physical operation buttons on the right side support one-button start, printing, and rinsing, allowing for precise operation even while wearing medical gloves.
► Features
1. Five-part differential white blood cell count
Supports simultaneous blood count and CRP inflammatory marker testing in a single tube, eliminating the need for secondary blood collection. Quickly identifies bacterial/viral infections, significantly improving outpatient diagnostic efficiency.
2. Dual-mode sample introduction
Supports batch east-west sample introduction and automatic continuous testing, allowing selection based on needs. Suitable for large-volume and individual testing.
3. Automatic Early Warning Mechanism
Automatically identifies abnormal samples such as hemolysis and lipemia, displaying abnormal warning icons on the screen to assist technicians in quickly verifying specimens.
4. Large-Capacity Long-Acting Reagents
The device uses large-capacity original reagents, with a single bottle supporting 1200 tests. Reagents are stable for 90 days after opening. The device monitors reagent levels in real time, providing an early warning when levels are low to prevent interruptions during testing.
5. Powerful Storage Capacity
The device's built-in hard drive can store 1 million complete tests, searchable by patient name, visit number, and test date. Equipped with a USB interface, it seamlessly connects to hospital systems, supporting thermal printing and exporting electronic reports.
► Parameters
|
Product name |
Blood Cell Analyzer |
|
Model |
CH8600CS |
|
Screen Size |
10.4 Inch |
|
Weight |
About 28KG |
|
Applicable occasions |
Hospital laboratory departments, laboratories |
|
Storage capacity |
Over 1 million test reports |
|
Material |
Plastic cover |
|
Shipping by |
Air or Express |
|
Lead time |
3-5 working days |
|
Language |
English/Chinese |
► Product Picture
![]()
![]()
►FAQ
Q1: What is the maximum number of blood collection tubes that can be placed in a single batch autosampler? Are there any requirements for tube specifications?
A1: The dual trays can hold 20 standard anticoagulant blood collection tubes at a time. Irregularly shaped blood collection tubes cannot be autosampled and must be tested in manual mode.
Q2: If reagents run out during batch testing of medical examination samples, will the equipment automatically clear all tested data?
A2: No, the machine will stop after the currently being tested is completed. All completed reports will be automatically saved. After replacing the reagents, there is no need to retest the completed samples.
Q3: After prolonged use, blood clots remain on the outer wall of the sampling needle. Can they be cleaned using the routine cleaning procedure?
A3: Mild blood clots can be removed by routine rinsing; stubborn blood clots require a special enzyme cleaning and soaking procedure at least once a week. Accumulated blood clots can cause cross-contamination of samples, affecting testing accuracy.
![]()