China World Technology Medical Equipment Service Group
Win-win together!
| Brand Name: | Mindray |
| Model Number: | T8 |
| Minimum Order Quantity: | 1 |
|---|---|
| Delivery Time: | 3-5 working days |
| Payment Terms: | T/T, Western Union,Paypal |
| Part Number: | 051-000193-00 6800-20-50051 | Product Name: | Power Board |
|---|---|---|---|
| AC Input Range: | 100–240 VAC, 50/60 Hz | DC Outputs: | +3.3 V, +5.0 V, +12 V |
| Protection Mechanisms: | Overvoltage Protection | Operating Temperature Range: | 0°C To 40°C |
| Payment: | T/T, Western Union,Paypal | Warranty: | 90 Days |
| Highlight: | Mindray T8 patient monitor power board,patient monitor power board 051-000193-00,Mindray T8 monitor power board 6800-20-50051 |
||
Mindray T8 Patient Monitor Power Board 051-000193-00 6800-20-50051
Product Introduction
The power supply board (part numbers 051-000193-00 and 6800-20-50051) is the main power unit inside the Mindray BeneView T8 patient monitor. Located on the back of the monitor, this board receives input power from AC power or the built-in battery and converts it into a stable DC voltage that all other components of the monitor rely on to operate.
What appears to be a single circuit board is actually a module containing four independent PCBs: a charging and power management board, a buck DC inverter, a boost/buck DC inverter, and a 5V CIS buck power supply board. Together, they are responsible for all functions from battery charging to voltage regulation of the various subsystems of the monitor.
![]()
Outputs with Description
Goes to the LCD, mother board, CPU board, DVI interface board and integral module rack.
Goes to the DVI interface board, recorder, CF storage card board and USB interface board.
CIS Goes to the CIS assembly.
Goes to the recorder, LCD inverter, integral module rack, parameter modules and USB interface board.
Precautions for use
1. Leave replacement and servicing to trained professionals. The power board is an internal component that sits close to high‑voltage circuits. Only qualified biomedical engineers or authorised Mindray service technicians should open the monitor, remove the board, or install a new one. Clinical staff should never attempt these procedures themselves.
2. Always disconnect power and remove batteries before working. Before any work begins, the monitor must be powered off, unplugged from the wall outlet, and both lithium‑ion batteries taken out. prevents accidental short circuits while handling the board.
3. Watch out for stored charge. The power board contains capacitors that can hold a dangerous electrical charge even after the monitor has been disconnected. Give the capacitors a few minutes to discharge naturally before touching the board, and follow the specific safety steps outlined in the service manual.
Contact Person: Rita
Tel: +8618279091952