logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

Mindray D3 Defibrillator Electrode Handle Interface Fixing Plastic Clip 043-00-1116-00

Mindray D3 Defibrillator Electrode Handle Interface Fixing Plastic Clip 043-00-1116-00

  • Mindray D3 Defibrillator Electrode Handle Interface Fixing Plastic Clip 043-00-1116-00
  • Mindray D3 Defibrillator Electrode Handle Interface Fixing Plastic Clip 043-00-1116-00
  • Mindray D3 Defibrillator Electrode Handle Interface Fixing Plastic Clip 043-00-1116-00
  • Mindray D3 Defibrillator Electrode Handle Interface Fixing Plastic Clip 043-00-1116-00
  • Mindray D3 Defibrillator Electrode Handle Interface Fixing Plastic Clip 043-00-1116-00
  • Mindray D3 Defibrillator Electrode Handle Interface Fixing Plastic Clip 043-00-1116-00
Mindray D3 Defibrillator Electrode Handle Interface Fixing Plastic Clip 043-00-1116-00
Product Details:
Brand Name: Mindray
Model Number: D3
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,Paypal
Contact Now
Detailed Product Description
Part Number: 043-00-1116-00 Product Name: Electrode Handle Interface Fixing Plastic Clip
Compatible Device: Mindray BeneHeart D3 Connector Type: Snap‑in
Material: Plastic Color: White
Protection: IPX-4 Payment: T/T, Western Union,Paypal
Warranty: 90 Days
Highlight:

Mindray D3 defibrillator electrode handle clip

,

defibrillator interface fixing plastic clip

,

patient monitor parts with warranty

Mindray D3 Defibrillator Electrode Handle Interface Fixing Plastic Clip 043-00-1116-00

 

Product Introduction

 

This small plastic clip 043-00-1116-00 is a structural component that sits at the connection point between the defibrillator's handle (or paddle) and the main unit of the Mindray D3. It's molded from high-strength medical-grade engineering plastic and serves as a critical mechanical and electrical interface.

This clip is one of those parts that quietly determines whether the defibrillator works when it's needed most. It's considered a consumable, wear-prone component, and its condition directly affects the safety and reliability of the entire defibrillation system.

 

Mindray D3 Defibrillator Electrode Handle Interface Fixing Plastic Clip 043-00-1116-00 0

 

Advantages

 

The clip acts as a barrier between the metal terminals at the handle interface, preventing high voltage leakage, arcing, and the risk of to clinical staff. It also helps protect against short circuits caused by moisture or dust accumulation.

 

Locks the handle firmly in place. As a locking component, the clip works with the therapy socket and handle plug to form a precision snap-fit mechanism. This keeps the handle securely attached to the main unit, preventing loosening or poor contact even when the device is being moved around or during emergency procedures. Stable transmission of both high-voltage energy and control signals depends on this secure fit.

 

Guides the handle for quick, blind insertion. The clip has built-in guide channels and positioning catches that help align the handle plug correctly with the interface. This allows for fast, one-handed insertion even in high-stress situations where every second counts. At the same time, the insertion and removal resistance is tuned so the handle stays locked when needed but can still be detached quickly with one hand.

 

 

General removal procedure 

  1. Open the main housing of the D3 using the appropriate tools.

  2. Locate the handle interface assembly and the fixing clip.

  3. Carefully disengage the clip from its locking position.

  4. Remove the clip and inspect it for any cracks, deformation, or wear.

Installation procedure:

  1. Position the new clip in place, ensuring it aligns correctly with the guide channels.

  2. Press it firmly until it snaps into its locked position.

  3. Verify that the clip is securely seated and that the handle can be inserted and removed smoothly.

  4. Close the housing and reinstall the battery.

  5. After reassembly, run a full functional test of the defibrillator, including a manual defibrillation test, to confirm everything is working correctly.

Precautions

 

  • Inspect the clip regularly. Because it's a wear-prone component, the clip should be checked periodically for cracks, deformation, or signs of aging. If the clip is damaged, it needs to be replaced promptly—don't wait until the handle starts feeling loose.

 

  • Check the handle connection after any service work. After removing and reinstalling the clip, make sure the handle plugs in securely and you hear it click into place. A loose connection can cause energy loss or discharge failure during defibrillation.

 

  • Keep the interface area clean. Dust, moisture, or disinfectant residue can accumulate around the clip and interface. Regular cleaning helps maintain both the electrical insulation properties and the mechanical function of the clip.

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: +8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.