China World Technology Medical Equipment Service Group
Win-win together!
| Brand Name: | Comen |
| Model Number: | STAR8000C |
| Minimum Order Quantity: | 1 |
|---|---|
| Delivery Time: | 3-5 working days |
| Payment Terms: | T/T, Western Union,Paypal |
| Part Number: | CME4D4B.10441 | Compatible Device: | Comen STAR8000C Patient Monitor |
|---|---|---|---|
| Input Impedance: | >10 MΩ | Input Range: | ±5 mV |
| ADC Resolution: | 16‑bit | Standby Power Consumption: | <0.5WInput Voltage Accuracy |
| Sampling Rate: | 8,000 Samples | Operating Temperature: | 0 °C To 40 °C |
| Parameters Include: | NIBP , ECG , SpO₂ | Operating Humidity: | 15% To 85% RH |
| Highlight: | STAR8000C patient monitor board,Comen parameter board with warranty,Patient monitor replacement parts |
||
CME4D4B.10441 Comen STAR8000C Patient Monitor Parameter Board
Product Description
This parameter acquisition board is a dedicated internal circuit module customized for the Comen STAR8000C bedside monitor. As the core signal acquisition and processing unit for vital sign monitoring, it independently acquires, filters, and converts the raw physiological signals picked up by external monitoring sensors, and transmits the processed digital data to the monitor's mainboard for real-time calculation and display.
The front end circuitry has an input impedance exceeding 10 MΩ, enabling the board to reliably acquire extremely weak bioelectrical potential signals from patients without loading the electrodes. The input stage also incorporates a defibrillation protection network to protect sensitive components when the monitor is connected to a patient receiving emergency defibrillation.
![]()
Parameter Area
![]()
ECG —Heart Rate or Pulse Rate(①,unit:bpm) —pacer detection ( PACE ② ) —ST-segment of channel 1 and channel 2 (③, unit: mv) — PVCs times (④ Unit: times/minute)
SpO2 —SpO2(⑤,unit:%) —Pulse Rate(unit:bpm)
IBP (optional) — Invisive Blood Pressure (From left to right) Systolic, Diastolic, Mean (⑥, Unit: mmHg or kPa)
NIBP — None-Invisive Blood Pressure (From left to right) Systolic, Diastolic, Mean (⑦, Unit: mmHg or kPa)
RESP —Respiration Rate(⑧,unit:bpm)
TEMP —TEMP —Temperature(⑨,unit: or ℃℉)
CO2 (optional) —end-tidal CO2 (⑩, Unit: mmHg or kPa) —inspiratory CO2 (11, Unit: mmHg or kPa)
1. This parameter board acquires and purifies high-precision raw physiological signals from external patient sensors to eliminate noise interference from surrounding medical equipment. The standard digital signal is then output to the mainboard for further data analysis.
2. A built-in protection chip enables real-time detection of abnormal signal inputs. In the event of signal interruption or circuit malfunction, a corresponding fault code will be sent to the monitoring system, facilitating rapid troubleshooting by maintenance personnel.
3. It supports synchronous transmission of multi-channel vital sign data, ensuring waveform synchronization and consistent numerical display during long-term continuous monitoring, without data delay or frame loss.
Contact Person: Rita