logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsECG Replacement Parts

Philiph TC10 ECG Machine Keypad 453564403411 453564403421 Original Parts for Medical Device

Philiph TC10 ECG Machine Keypad 453564403411 453564403421 Original Parts for Medical Device

  • Philiph TC10 ECG Machine Keypad 453564403411 453564403421 Original Parts for Medical Device
  • Philiph TC10 ECG Machine Keypad 453564403411 453564403421 Original Parts for Medical Device
  • Philiph TC10 ECG Machine Keypad 453564403411 453564403421 Original Parts for Medical Device
  • Philiph TC10 ECG Machine Keypad 453564403411 453564403421 Original Parts for Medical Device
  • Philiph TC10 ECG Machine Keypad 453564403411 453564403421 Original Parts for Medical Device
Philiph TC10 ECG Machine Keypad 453564403411 453564403421 Original Parts for Medical Device
Product Details:
Model Number: TC10
Payment & Shipping Terms:
Minimum Order Quantity: 1 Piece
Price: USD
Delivery Time: 3-5 working days
Payment Terms: T/T,Western Union,Paypal
Contact Now
Detailed Product Description
Product Name:: Keypad Model:: 453564403411 453564403421
Type:: Spare Parts Condition:: Used-Good
Application:: TC10 Material:: PCB Board
MOQ:: 1 Piece Warranty:: 90 Days
Serve:: Direct Sales, Exchanges, Repairs PAYMENT TERMS:: Pay In Full Before Shipment
Highlight:

Philiph TC10 ECG machine keypad

,

Original ECG replacement parts

,

Medical device keypad 453564403411

Philiph TC10 ECG Machine Keypad 453564403411 453564403421 Original Parts for Medical Device

 
 Philiph TC10 ECG Machine Keypad 453564403411 453564403421


 
► Brief Introduction
 

This is the original, disassembled keypad from the TC10 ECG machine. The keypad's part numbers are 453564403411 and 453564403421. Located on the top of the device, below the main buttons, it has three button sensors: power on/off, mode selection, and freeze. Pressing the corresponding button activates the keypad, which receives the pressure signal and transmits it to the mainboard. The mainboard then issues the relevant commands to achieve the desired operation.


 
 
Features

1. Button Signal Transmission: Converts external pressure signals into corresponding button signals and transmits them to the mainboard, ensuring accurate signal transmission and timely response.

 

2. Simplified Operation: Centralizes the main functions, simplifying the device's operation, ensuring its focus and specialization, and avoiding cumbersome procedures that could affect operational efficiency.

 

3. Highly Durable Device

The button panel uses high-lifespan buttons, suitable for high-frequency clinical pressing scenarios. It offers clear tactile feedback, is less prone to collapse or malfunction, reducing operational abnormalities caused by button failure and extending device lifespan.

 

4. Stable Signal Transmission

Optimized PCB board routing design reduces the impact of internal electromagnetic interference on button signals, avoiding misoperation and button malfunction, ensuring stable response to operation commands even in complex environments.


 
► Parameters

Product name

Keypad

PN

453564403411 453564403421

Machine model

TC10

Shipping by

Air or express

Condition

Working well

Material

PCB board

Warranty

90 days

Weight

About 80g

MOQ

1PC

 
 
► Product Picture
 
Philiph TC10 ECG Machine Keypad 453564403411 453564403421 Original Parts for Medical Device 0
Philiph TC10 ECG Machine Keypad 453564403411 453564403421 Original Parts for Medical Device 1
 
 
After-sales issues
 
Our warranty time is 90 days after delivery. Before packing, we will check the goods model carefully, and if the product is in used condition, there are professional engineers who will test the functions of it. Only the test is qualified then we will pack carefully to ensure that you can receive satisfactory and workable goods. And please check the goods asap after you receiving them. If you have any questions, please feel free to contact us.
 
►FAQ
 

Q1: If the device buttons are unresponsive or slow to react, is it definitely a problem with the button panel?

A1: Not necessarily. First, check if the ribbon cable is loose or oxidized, or if the display interface board/main board is faulty. If the problem persists after replacing the ribbon cable, it's likely that the switch on the button panel is damaged or there's a PCB circuit fault, requiring replacement of the entire board.


Q2: Does replacing the button panel require soldering? Can I do it myself?

A2: No soldering is required. Replacement can be completed simply by plugging and unplugging the ribbon cable and fixing screws. Follow professional guidance for replacement; no special soldering tools are needed.


Q3: Can the buttons on the button panel be replaced individually? Q3: Is it necessary to replace the entire board?

A3: Replacing a single button is not recommended. The button and PCB board are integrated; soldering and replacing a single button can easily damage the circuitry or cause poor contact. Replacing the entire button board is more stable and can prevent subsequent button malfunctions.

 

A4: After replacing the button board, do the device's operating functions need to be reconfigured?

A4: No. The button board is only responsible for signal acquisition and does not involve device software settings. After replacement, the device can directly recognize the button signals without additional calibration or settings.


Philiph TC10 ECG Machine Keypad 453564403411 453564403421 Original Parts for Medical Device 2 Philiph TC10 ECG Machine Keypad 453564403411 453564403421 Original Parts for Medical Device 3
90 Day Warranty                             SGS ceryification

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Bella

Tel: 86-18879075074

Send your inquiry directly to us
Other Products
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.