logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsECG Replacement Parts

Philiph TC10 ECG Machine Battery Board 453564402661 453564402671 Replacement Spare Parts

Philiph TC10 ECG Machine Battery Board 453564402661 453564402671 Replacement Spare Parts

  • Philiph TC10 ECG Machine Battery Board 453564402661 453564402671 Replacement Spare Parts
  • Philiph TC10 ECG Machine Battery Board 453564402661 453564402671 Replacement Spare Parts
  • Philiph TC10 ECG Machine Battery Board 453564402661 453564402671 Replacement Spare Parts
  • Philiph TC10 ECG Machine Battery Board 453564402661 453564402671 Replacement Spare Parts
Philiph TC10 ECG Machine Battery Board 453564402661 453564402671 Replacement Spare Parts
Product Details:
Brand Name: Philiph
Model Number: TC10
Payment & Shipping Terms:
Minimum Order Quantity: 1 Piece
Price: USD
Delivery Time: 3-5 working days
Payment Terms: T/T,Western Union,Paypal
Contact Now
Detailed Product Description
Product Name:: Battery Board P/N:: 453564402661 453564402671
Model:: TC10 Condition:: Used-Good
Application:: TC10 ECG Machine MOQ:: 1 Piece
Weight:: 30g Warranty:: 90 Days
Shipping Method:: Express PAYMENT TERMS:: Pay In Full Before Shipment
Highlight:

Philiph TC10 ECG battery board

,

ECG machine replacement spare parts

,

Philiph TC10 ECG parts with warranty

Philiph TC10 ECG Machine Battery Board 453564402661 453564402671

 
 
 
 
► Brief Introduction
 

This is the battery interface board for the Philiph TC10 ECG machine. This board is a salvaged part from the TC10 machine and is an original manufacturer part. Part numbers 453564402661 and 453564402671 are compatible with original batteries. The battery interface board is installed at the bottom of the battery compartment and includes a cable and a small PCB board. The cable connects to the machine's main board, and the PCB board has contacts for connecting to the battery's contacts, enabling power transfer and signal exchange between the battery and the main board. It also handles the transmission of battery status and related signals.


 
Features

1. Battery Power Transmission: The battery board has a built-in cable that transmits battery power to the main board and distributes it to various critical components for normal operation of the machine.

2. Battery Status Recognition

The battery interface board's cables not only transmit power but also transmit battery feedback signals to the motherboard, such as low battery warnings and battery fault codes, ensuring normal communication between the battery and the motherboard.

3. Electrical Protection and Foolproof Design

The battery interface board features a built-in reverse connection protection circuit to prevent damage to the device's motherboard caused by incorrect battery insertion. The interface has a foolproof positioning feature, preventing incorrect insertion during installation and physically eliminating the risk of accidental operation, ensuring the safety of both the device and the battery.

4. Easy Installation

This interface board is specifically designed for the Philiph TC10 model. The PCB size and interface pins are 100% compatible. Installation is simple: just replace the board without additional debugging or calibration, quickly restoring the device's power supply function.


 
► Parameters
 

Product name

Battery Board  

P/N

453564402661 453564402671

Machine model

TC10

Shipping by

Air or express

Condition

Working well

Material

PCB board

Color

Green

Weight

About 200g

Warranty

90 days

 
 
► Product Picture
 
Philiph TC10 ECG Machine Battery Board 453564402661 453564402671 Replacement Spare Parts 0
Philiph TC10 ECG Machine Battery Board 453564402661 453564402671 Replacement Spare Parts 1
 
 
►FAQ
 

Q1: Can I repair a bent pin on the battery interface board?

A1: Repair is not recommended. The pins are gold-plated, requiring soldering for repair, which is difficult and prone to problems such as poor contact after repair. It is recommended to replace the entire interface board to avoid repeated failures.


Q2: The device displays "Battery cannot be charged." Is this related to the interface board?

A2: Yes. The interface board is responsible for transmitting charging signals. If the charging circuitry on the interface board is damaged, the device will not be able to charge the battery even if the charger is working properly.


Q3: Do I need special tools to replace the interface board? Can I install it myself?

A3: Installation is very simple. Just tighten the screws with a screwdriver and then plug the connectors at both ends firmly. No special tools or soldering are required. Medical or repair personnel can quickly complete the replacement.


Philiph TC10 ECG Machine Battery Board 453564402661 453564402671 Replacement Spare Parts 2 Philiph TC10 ECG Machine Battery Board 453564402661 453564402671 Replacement Spare Parts 3
90 Day Warranty                             SGS ceryification

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Bella

Tel: 86-18879075074

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.