logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Accessories

M-11 oxygen sensor for Stephan Ventilator new original medical equipment accessories

M-11 oxygen sensor for Stephan Ventilator new original medical equipment accessories

  • M-11 oxygen sensor for Stephan Ventilator new original medical equipment accessories
  • M-11 oxygen sensor for Stephan Ventilator new original medical equipment accessories
  • M-11 oxygen sensor for Stephan Ventilator new original medical equipment accessories
  • M-11 oxygen sensor for Stephan Ventilator new original medical equipment accessories
  • M-11 oxygen sensor for Stephan Ventilator new original medical equipment accessories
  • M-11 oxygen sensor for Stephan Ventilator new original medical equipment accessories
M-11 oxygen sensor for Stephan Ventilator new original medical equipment accessories
Product Details:
Brand Name: No
Model Number: M-11
Payment & Shipping Terms:
Minimum Order Quantity: 1 Piece
Price: USD
Packaging Details: Standard Export Packing
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union, Paypal
Supply Ability: In stock
Contact Now
Detailed Product Description
Brand: No Product Name: Oxygen Sensor
Model: M-11 MOQ: 1 Piece
Warranty: 90 Days Use For: Stephan Ventilator
Condition: New Original Inventory: In Stock
Payment Method: Paypal,T/T,Western Union Delivery Method: DHL, FEDEX, UPS, Etc.
Highlight:

M-11 oxygen sensor for Stephan Ventilator

,

original medical equipment oxygen sensor

,

Stephan Ventilator patient monitor accessories

M-11 oxygen sensor for Stephan Ventilator new original 

 

 

► Brief Description

 

The M-11 oxygen sensor is a new original for the Stephan Ventilator. This sensor has a signal output range of 0.8-12.5mV, a resolution of up to 0.1%, an oxygen concentration measurement range of 0-100%, a service life of up to 4 years, a response time as low as 5 seconds, and a loading resistance greater than 1MΩ. The M-11 oxygen sensor plays a crucial role in ventilators. It is primarily used to measure the oxygen concentration of the mixed gas, unrelated to oxygen concentration control, but as a terminal monitoring method, it can promptly detect whether the oxygen concentration is accurate. When the sensor output voltage exceeds the normal range or the measured value deviates significantly from the set value, the ventilator will issue an alarm.It is compatible with F120, Alia, Stephanie ventilators, CPAP type A/B/C, and the entire Stephan anesthesia machine series.

 

► Specifications

 

Part number M-11
Use for Stephan Ventilator
Product Name oxygen sensor
Condition New Original
MOQ 1 Piece
Delivery Method DHL ,Fedex ,UPS
Payment Method Paypal,T/T,Western Union
Warranty 90 Days
Color White
Delivery time 3-5 Working Days
Stock Situation Stock available
Payment Terms Full Before Shipment
Measurement range 0-100 %

 

 

►Detailed Photos

 

M-11 oxygen sensor for Stephan Ventilator new original medical equipment accessories 0

 

►Replacement Procedure

 

1. Locating and Removing

The oxygen cell (sensor) is typically located between the patient's inspiratory end and the air-oxygen mixer.

 

The sensor connects to the ventilator's circuitry via a physical interface.

 

Once the sensor is located, carefully disconnect its electrical connection, then remove the old sensor from its slot or airway.

 

2. Installing the New Sensor

Verification and Cleaning: Remove the new M-11 sensor and confirm the model is correct. Check for any external damage and ensure the interface is compatible.

 

Installing the Sensor: Insert the new sensor into the slot in the correct orientation. You may need to press it in firmly to ensure a seal at the airway interface.

 

Connecting the Cable: Securely insert the sensor's connector into the corresponding port on the ventilator.

 

3. Power-On Test

After installation, connect the ventilator to power and air supply and turn it on.

 

4. Calibration

 

Enter Calibration Mode: In the ventilator's main menu or settings menu, locate "FiO2 Calibration" or a similar option.

 

Introduce calibration gas: As prompted on the screen, the ventilator may automatically introduce a gas of known oxygen concentration into the sensor via a solenoid valve.

 

Wait for calibration to complete: During the calibration process, the ventilator screen may display "CAL". Please wait patiently until the calibration procedure is completed automatically. Once complete, the device will automatically switch back to normal measurement mode.

 

►Warning:

 

It is important to note that the actual service life of the M-11 oxygen sensor is affected by the operating environment: use in high oxygen concentration or high temperature environments will shorten its lifespan. Therefore, regular inspection and timely replacement of the oxygen sensor are necessary measures to ensure the normal operation of the ventilator. Especially when abnormalities are detected in the inhaled oxygen concentration monitoring, the oxygen battery should be considered as potentially failing or nearing the end of its lifespan.

 

►FAQ:

 

Q1: How often should I replace the M-11 oxygen sensor?
A1: Typically every 2-4 years, but high oxygen concentrations or temperatures may shorten its lifespan.

 

Q2: Is this an original or compatible sensor?
A2: This is a brand new original M-11 sensor manufactured for Stephan ventilators.

 

Q3:What is the product warranty period?
A3: All products have a 90-day warranty, we can replace or refund you within the warranty period.

 

If you want to explore more details about the M-11 oxygen sensor for Stephan Ventilator new original , please contact us at anytime. Looking forward to hearing from you.

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Mia

Tel: 86-15779588554

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.