China World Technology Medical Equipment Service Group
Win-win together!
| Brand Name: | Drager |
| Model Number: | Savina 300 |
| Minimum Order Quantity: | 1 |
|---|---|
| Delivery Time: | 3-5 working days |
| Payment Terms: | T/T, Western Union,Paypal |
| Model: | Savina 300 | Part Number: | 8414000-24 |
|---|---|---|---|
| Patient Types: | Adult, Pediatric, Infants ≥5 Kg (11 Lbs) | Tidal Volume: | 0.05 To 2.0 L (BTPS) |
| Respiratory Rate: | 2/min To 80/min | Inspiratory Time: | 0.2 To 10 S |
| Inspiratory Flow: | Up To 250 L/min | Inspiratory Pressure: | 1 To 99 Mbar (cmH₂O) |
| O₂ Concentration: | (FiO₂)21% To 100% | Display: | 12.1" Color Touch Screen |
| Highlight: | Drager Savina 300 ventilator,intensive care ventilator device,used patient monitor ventilator |
||
Drager Savina 300 Series Of Intensive Care Ventilators 8414000-24 Device
Introduction
This turbine-driven intensive care ventilator combines the independence of a turbine-driven ventilation system with advanced ventilation modes. It is suitable for adult and pediatric patients weighing 5 kg (11 lbs) and above, meeting a variety of clinical application needs from general wards to in-hospital transport. The ventilator provides both tubing and mask ventilation, with air supplied from the environment and oxygen from a central ventilation system, oxygen cylinders, or a low-pressure oxygen source. The system features a 12.1-inch color touchscreen, allowing users clear and convenient access to settings, parameters, and control options. The user interface includes a large touchscreen navigation and a dedicated rotary knob for quick and intuitive parameter adjustments. The front panel features a smooth, sealed surface design. The device's open-breathing concept allows patients to breathe freely at any time and pressure level during the treatment cycle, promoting spontaneous breathing and improving overall patient comfort.
![]()
Patient connection panel
![]()
A Nebulizer port (nebulizer gas outlet for pneumatic medication nebulizer)
B Inspiratory valve with inspiratory port Insp. (GAS OUTPUT)
C Fastening screw for cover plate (behind cover: O2 sensors)
D Water trap of expiratory valve
E Expiratory valve with expiratory port Exp. (GAS RETURN)
F Flow sensor flap (behind flap: flow sensor)
G Gas outlet Exhaust, non-conical connection (EXHAUST – NOT FOR SPIROMETER)
Functions
1. No High-Pressure Air Source Required: Built-in turbine technology allows for autonomous air extraction, independent of the central air supply system, facilitating easy transport.
2. Extremely Long Battery Life: Built-in battery + optional external battery, supporting up to 5–7 hours of uninterrupted ventilation, remaining reliable even during power outages or transport.
3. Widely Applicable to Children: Suitable for adults, children, and infants weighing ≥5 kg.
4. Multiple Ventilation Modes: Supports volume control, pressure control, spontaneous breathing, and advanced modes such as PC-APRV and AutoFlow.
5. Intelligent Leak Compensation: Automatically compensates for leaks in non-invasive ventilation (NIV) mode, improving ventilation stability and patient comfort.
6. High-Flow Oxygen Therapy in One Unit: Enables high-flow oxygen therapy, non-invasive ventilation, and invasive ventilation on the same device without the need to replace the machine.
7. Rapid Trigger Response: The turbine responds quickly, making patient triggering easier, reducing patient-ventilator aggression, and facilitating weaning.
8. Touchscreen + Knob Operation: The 12.1-inch touchscreen combined with a "touch-rotate-confirm" logic allows for quick learning and simple setup.
9. Easy to clean: The smooth, sealed surface allows for rapid disinfection, reducing the risk of hospital-acquired infections.
10. Automatic self-test: The device automatically checks itself upon startup to ensure it is always ready for use.
1. This medical device is equipped with basic safety functions. It can reduce the risk of patient injury during the troubleshooting of alarm faults.
The core working performance focuses on controlled and monitored patient ventilation. All monitoring items can be adjusted according to user settings.
2. Customizable monitoring parameters include minimum ventilation flow, maximum airway pressure, and the upper and lower limits of oxygen concentration in breathing gas.
3. The system will activate corresponding alarms once any set parameter limit is exceeded.
4. The built in monitoring system can also send out alarms for common faults.
5. The related situations cover external power failure, internal battery depletion and oxygen supply failure under HPO mode.
Contact Person: Rita
Tel: +8618279091952