logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

Nihon Kohden BSM-4113K Patient Monitor NIBP Module 6190-027473 UR-3567 Blood Pressure Measurement Unit

Nihon Kohden BSM-4113K Patient Monitor NIBP Module 6190-027473 UR-3567 Blood Pressure Measurement Unit

  • Nihon Kohden BSM-4113K Patient Monitor NIBP Module 6190-027473 UR-3567 Blood Pressure Measurement Unit
  • Nihon Kohden BSM-4113K Patient Monitor NIBP Module 6190-027473 UR-3567 Blood Pressure Measurement Unit
  • Nihon Kohden BSM-4113K Patient Monitor NIBP Module 6190-027473 UR-3567 Blood Pressure Measurement Unit
  • Nihon Kohden BSM-4113K Patient Monitor NIBP Module 6190-027473 UR-3567 Blood Pressure Measurement Unit
  • Nihon Kohden BSM-4113K Patient Monitor NIBP Module 6190-027473 UR-3567 Blood Pressure Measurement Unit
  • Nihon Kohden BSM-4113K Patient Monitor NIBP Module 6190-027473 UR-3567 Blood Pressure Measurement Unit
  • Nihon Kohden BSM-4113K Patient Monitor NIBP Module 6190-027473 UR-3567 Blood Pressure Measurement Unit
  • Nihon Kohden BSM-4113K Patient Monitor NIBP Module 6190-027473 UR-3567 Blood Pressure Measurement Unit
Nihon Kohden BSM-4113K Patient Monitor NIBP Module 6190-027473 UR-3567 Blood Pressure Measurement Unit
Product Details:
Brand Name: Nihon Kohden
Certification: CE/CB/ROSH
Model Number: BSM-4113K
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: USD
Packaging Details: Carton
Payment Terms: L/C, D/A, D/P, T/T
Contact Now
Detailed Product Description
Product Name: NIBP Module Model: 6190-027473 UR-3567
Material: PCB Function: Blood Pressure Monitoring
Product Type: Medical Spare Part Machine Application: BSM-4113K
Voltage: 12V DC Warranty: 90 Days
Component: Pump & Valve Assembly Condition: Original
Highlight:

Nihon Kohden BSM-4113K NIBP module

,

patient monitor blood pressure unit

,

NIBP module with warranty

Nihon Kohden BSM-4113K Patient Monitor NIBP Module 6190-027473 UR-3567 Blood Pressure Measurement Unit


  • Product Description
This Original Nihon Kohden NIBP Module is a core component designed for the BSM-4100 series patient monitors, with Part Number 6190-027473 and Model UR-3567. Integrating a high-precision air pump, solenoid valve block, and pressure sensor, this module accurately measures non-invasive blood pressure in clinical settings. As seen in the images, the circuit board features high-quality construction with a clear "NIBP SAFETY" marking, indicating over-pressure protection for patient safety. It is the ideal replacement for restoring BP monitoring functions in ICUs, operating rooms, and emergency departments.

 Nihon Kohden BSM-4113K Patient Monitor NIBP Module 6190-027473 UR-3567 Blood Pressure Measurement Unit 0

 

  • Product Specifications

 

Product Name NIBP Module
Model 6190-027473 UR-3567
Material PCB
Function Blood Pressure Monitoring
Color Green
Warranty 90 days

 

 

  • Use Tips

1. Installation:

Ensure the monitor is powered off. Open the case, locate the old NIBP module, disconnect the ribbon cables and air tubes, unscrew the mounting screws, and replace it with the new module.

 

2. Tube Connection:

Pay attention to the air tube orientation; ensure connections are tight to prevent air leaks.

 

3. Calibration:

After replacement, it is recommended to enter Service Mode to perform pressure calibration for accuracy.

 

 

Fault Diagnosis
The cuff continues to inflate and cannot automatically release pressure, indicating that the solenoid valve is stuck or damaged.
The inflation process is abnormally slow and the air pump heats up, indicating internal wear and aging of the air pump.
Significant fluctuations in measurement values or inability to display pulse rate indicate a failure of the pressure sensor.
The host screen directly displays "NIBP Sensor Error", confirming a hardware failure in the module.
The air pump is running normally but the pressure cannot increase, indicating that there is a leak in the internal air circuit of the module.

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Mandy

Tel: 86-15070124795

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.