logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

GE PRO1000 Patient Monitor Parameter Panel Component 2012709-001 for Hospital ICU

GE PRO1000 Patient Monitor Parameter Panel Component 2012709-001 for Hospital ICU

  • GE PRO1000 Patient Monitor Parameter Panel Component 2012709-001 for Hospital ICU
  • GE PRO1000 Patient Monitor Parameter Panel Component 2012709-001 for Hospital ICU
  • GE PRO1000 Patient Monitor Parameter Panel Component 2012709-001 for Hospital ICU
  • GE PRO1000 Patient Monitor Parameter Panel Component 2012709-001 for Hospital ICU
  • GE PRO1000 Patient Monitor Parameter Panel Component 2012709-001 for Hospital ICU
  • GE PRO1000 Patient Monitor Parameter Panel Component 2012709-001 for Hospital ICU
GE PRO1000 Patient Monitor Parameter Panel Component 2012709-001 for Hospital ICU
Product Details:
Brand Name: GE
Model Number: 2012709-001
Payment & Shipping Terms:
Minimum Order Quantity: 1 Piece
Price: USD
Packaging Details: Standard Export Packing
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union, Paypal
Supply Ability: In stock
Contact Now
Detailed Product Description
Model: 2012709-001 Brand: GE
Product Name: Parameter Panel Component MOQ: 1 Piece
Material: Plastic Warranty: 90 Days
Use For: GE PRO1000 Patient Monitor Condition: Used Original
Inventory: In Stock Payment Method: Paypal,T/T,Western Union
Delivery Method: DHL, FEDEX, UPS, Etc.
Highlight:

GE PRO1000 patient monitor panel

,

ICU patient monitor component

,

hospital monitor replacement part

GE PRO1000 Patient Monitor Parameter Panel Component 2012709-001

 

 
Brief Description


 This is the Parameter Panel Component for the GE PRO1000 Patient Monitor (Part Number: 2012709-001). Constructed from gray plastic, the panel is exceptionally sturdy and durable; it serves to protect internal cables and circuit boards while offering resistance against dust and water ingress. The surface is smooth and flat, featuring a prominent Masimo parameter interface and two attached red cables that connect directly to the monitor's internal circuitry. This panel is responsible for real-time monitoring of patient data and transmitting that information to the main board of the PRO1000 monitor.

 
► Specifications
 

Brand GE
Product Name Parameter Panel Component
Warranty 90 Days
Part number 2012709-001
Payment term Full before shipment
Delivery Method DHL ,Fedex ,UPS
Delivery 3-5 Working days
MOQ 1 Piece
Type Spare part
Material Plastic
Packing Carton
Inventory In stock
Condition Original
Color Grey

 
Detailed Photos
 
GE PRO1000 Patient Monitor Parameter Panel Component 2012709-001 for Hospital ICU 0

 

Parameter Panel Component Functions

 

1.ECG: Monitors heart rate and rhythm, and detects arrhythmias.

 

2.NIBP: Measures systolic pressure, diastolic pressure, and mean arterial pressure in adults, children, and neonates.

 

3.SpO2: Provides continuous monitoring via non-invasive pulse oximetry technology.

 

4.RESP: Monitors the patient's respiratory rate.

 

5.Alarm Management: The component integrates an alarm management system that triggers audible and visual alarms when monitored parameters exceed preset limits. A remote alarm function enables the transmission of alarm information to a central monitoring station.

 

Installation Steps

 

1. Power Off and Disconnect All Connections

Turn off the monitor's power supply, unplug the power cord connected to the main unit, and remove the battery to ensure the device is completely de-energized.

 

2. Disassemble the Monitor Casing

Using a suitable screwdriver, remove the screws securing the monitor's rear cover or bottom panel.

Carefully open the casing. Due to the intricate internal design of the monitor, it is recommended to handle the components gently to avoid straining or pulling on internal connecting cables.

 

3. Replace the Parameter Board

Locate the parameter board requiring replacement inside the monitor.

Carefully disconnect all ribbon cables or connectors attached to that parameter board. Note: Before disconnecting, it is advisable to take photos or make markings indicating the connection position and orientation of each cable to ensure correct re-installation later. Unscrew the fasteners securing the board and remove the old parameter board.

Align the new parameter board with the interface ports and mounting holes, then tighten the screws. Next, referring to the markings made earlier, reconnect all cables and connectors to their original positions, ensuring that all connections are secure.

 

4. Reassembly and Testing

Reattach the main unit's casing, tighten the screws, reinstall the battery, reconnect the power cord, and power on the device for testing.

After powering on, access the monitor's maintenance or service mode to perform functional tests on the newly installed parameter board, ensuring that it operates correctly and generates no alarm messages.

 

If you have any questions about the GE PRO1000 Patient Monitor Parameter Panel Component 2012709-001, please contact us at any time, looking forward to hearing from you.

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Mia

Tel: 86-15779588554

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.