BLT Biolight M66 Patient Monitor Connection Board Alarm Indicator Board Wiring

BLT Biolight M66 Patient Monitor Connection Board Alarm Indicator Board Wiring

  • BLT Biolight M66 Patient Monitor Connection Board Alarm Indicator Board Wiring
  • BLT Biolight M66 Patient Monitor Connection Board Alarm Indicator Board Wiring
  • BLT Biolight M66 Patient Monitor Connection Board Alarm Indicator Board Wiring
  • BLT Biolight M66 Patient Monitor Connection Board Alarm Indicator Board Wiring
BLT Biolight M66 Patient Monitor Connection Board Alarm Indicator Board Wiring
Product Details:
Place of Origin: China
Brand Name: Biolight
Certification: CE
Model Number: M66
Payment & Shipping Terms:
Minimum Order Quantity: 1 Piece
Price: USD
Packaging Details: Carton
Delivery Time: 3-5 working days
Payment Terms: T/T,Western Union,Paypal
Contact Now
Detailed Product Description
Product Name: Wiring Compatible Model: M66
Material: PVC Color: White
Condition: Good Working Weight: About 20g
Type: Patient Monitor Parts Warranty: 90 Days
Delivery Time: 7-15 Days Shipping By: DHL,FedEx
Highlight:

BLT Biolight M66 monitor connection board

,

patient monitor alarm indicator board

,

Biolight M66 wiring replacement part

BLT Biolight M66 Patient Monitor Connection Board Alarm Indicator Board Wiring

This cable connects the internal connection board and alarm indicator board of the M66 monitor. When a monitored value exceeds a preset threshold, the connection board transmits an alarm signal through this cable to the alarm indicator board, displaying a corresponding alarm signal, such as a red, yellow, or green light. Different lights illuminate depending on the alarm level or type, prompting medical personnel to take appropriate action.

The cable is approximately 20cm long, made of white PVC, with a white section at each end for connecting to the ports on the connection board and alarm indicator board, respectively. The cable uses a four-strand wire design, enabling simultaneous transmission of different signals without interference.

Features

1. Alarm Signal Transmission

Dedicated to transmitting alarm control signals from the connection board to the alarm indicator board (M9500LED01). The LEDs then illuminate or flash according to the alarm level, providing a visual alarm output.

2. Status Synchronization

Ensures perfect synchronization between alarm lights, device sound alarms, and screen prompts: the lights respond immediately to abnormal parameters and turn off synchronously when normal parameters are restored, avoiding alarm asynchrony.

3. Signal Isolation

The cable uses an independent routing design with four signal wires, transmitting different alarm signals separately to avoid electromagnetic interference affecting the stability of the alarm lights and prevent alarm delays or false flashes.

4. Modular Signal Path

Serving as a dedicated path between the connection board and the alarm light board, only this cable needs to be replaced in case of failure, without affecting other functions such as buttons and displays, facilitating precise maintenance.

Technical Specifications

Product name

Wiring

Connect to

Connection Board & Alarm Indicator Board

Model

M66

Type

Patients monitor machine

Material

PVC

Color

White

Warranty

90 days

MOQ

1 piece

Lead time

3-5 days

Delivery by

DHL, air

Product Images
BLT Biolight M66 Patient Monitor Connection Board Alarm Indicator Board Wiring 0
BLT Biolight M66 Patient Monitor Connection Board Alarm Indicator Board Wiring 1

FAQ

Q1: The alarm light is not on, but the audible alarm and screen display are working normally. Could this be a problem with the cable?

A1: Possibly. First, check the cable itself for damage or breakage, and whether the connection to the indicator board is loose. If the audible and screen alarms are normal, the mainboard control signal is normal, and the fault is likely with the cable or the indicator board itself. If the cable is normal after troubleshooting, it is recommended to replace the indicator board.

Q2: The alarm light is flashing randomly or the alarm color is incorrect. Is this related to the cable?

A2: Yes. If a signal wire inside the cable is short-circuited, it will cause an error in the transmission of the alarm level signal, manifested as incorrect light color and abnormal flashing pattern. Replace the cable and test again.

Q3: The indicator board occasionally flashes briefly and then goes out. Is this due to poor cable contact?

A3: Possibly. A damaged cable or loose connection can cause intermittent signal interruption, manifested as the light flashing and then going out. Re-plug the cable and clean the pins. If the problem persists, the cable needs to be replaced.

Ordering Information
Payment Methods Bank Transfer / PayPal / Western Union
Shipping Methods DHL / FedEx

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Bella

Tel: 86-18879075074

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.