China World Technology Medical Equipment Service Group
Win-win together!
| Brand Name: | PHiliph |
| Certification: | CE/CB/ROSH |
| Model Number: | M1657B |
| Minimum Order Quantity: | 1 |
|---|---|
| Price: | USD |
| Packaging Details: | Carton |
| Payment Terms: | L/C, D/A, D/P, T/T |
| Model: | M1657B | Product Name: | Water Trap |
|---|---|---|---|
| Material: | PC | Function: | Condensation Trapping |
| Warranty: | 90 Days | Flow Direction: | With Arrow |
| Packaging: | Individually Packaged | Color: | Transparent / Blue |
| Product Type: | Medical Consumable | Sterilization Method: | Ethylene Oxide (EO) |
| Highlight: | Philip water trap for anesthesia machine,ETCO2 monitor gas sampling line,patient monitor water trap accessory |
||
M1657B PHiliph Water Trap for ETCO2 Monitor Anesthesia Machine Gas Sampling Line
The M1657B Water Collection Cup is a specialized accessory designed for PHiliph monitors, serving as a critical component in sidestream End-Tidal CO2 monitoring systems. Constructed from transparent polycarbonate, it features a compact design with a blue locking latch and a clear gas flow arrow. Its primary function is to trap condensation water generated in the gas sampling line, preventing moisture from entering the sensitive sensor, thereby protecting the equipment and ensuring measurement accuracy.
![]()
| Product Name | Water Trap |
|---|---|
| Model | M1657B |
| Material | PC |
| Function | Condensation Trapping |
| Color | Transparent / Blue |
| Sterilization Method | Ethylene Oxide (EO) |
1. Pre-use Inspection:
Before use, check for cracks or deformation in the cup and ensure the packaging is intact.
2. Confirm Flow Direction:
When installing, strictly align the arrow on the cup with the gas flow direction (usually from the patient end to the monitor end).
3. Regular Monitoring:
Regularly check the water level during use. When the water accumulates to a certain height (usually recommended not to exceed half the cup), it should be emptied or replaced promptly to prevent water backflow into the sensor.
4. Replacement Frequency:
It is recommended to replace it daily or promptly when significant water accumulation is observed to maintain pipeline hygiene.
1. Do not sterilize this product using high-pressure steam, as it may cause plastic deformation.
2. Do not store or use in environments exceeding 40°C for prolonged periods.
3. Discontinue use immediately if the cup body cracks or the latch is damaged.