China World Technology Medical Equipment Service Group
Win-win together!
| Brand Name: | PHiliph |
| Certification: | CE/CB/ROSH |
| Model Number: | 867001 |
| Minimum Order Quantity: | 1 |
|---|---|
| Price: | USD |
| Packaging Details: | Carton |
| Payment Terms: | L/C, D/A, D/P, T/T |
| Model: | 867001 | Product Name: | CO2 Monitoring Module |
|---|---|---|---|
| Material: | Engineering Plastic | Interface Type: | Metal Connectors |
| Warranty: | 90 Days | Function: | End-tidal CO2 Monitoring |
| Moq: | 1 | Advantages: | High Precision, Durable, Easy To Install |
| Product Type: | Medical Sensor Module | Machine Application: | PHiliph Goldenway Patient Monitor |
| Highlight: | CO2 module for patient monitor,Goldenway medical capnography sensor,Philips patient monitor CO2 sensor |
||
GE DASH3000 DASH4000 DASH5000 NIBP Module 2000976-002 Non-Invasive Blood Pressure Pump Assembly
This PHiliph Goldenway 867001 CO2 Module is a medical accessory specifically designed for patient monitors. Its housing is made of durable white engineering plastic, with a compact design for easy installation and removal.
The front panel is labeled "CO2" and features two function buttons and a status indicator light for operation and monitoring. The back is equipped with two metal connectors for connecting sampling tubes, enabling sidestream gas sampling.
By accurately measuring end-tidal carbon dioxide concentration, this module provides healthcare professionals with real-time information on patient ventilation status, making it an essential monitoring tool in clinical anesthesia, intensive care, and emergency settings.
![]()
| Product Name | CO2 Monitoring Module |
|---|---|
| Model | 867001 |
| Material | Engineering plastic |
| Function | End-tidal CO2 Monitoring |
| Interface | Metal Connectors |
| Machine Application | PHiliph Goldenway Patient Monitor |
1. Regular Calibration and Self-Test:
It is recommended to perform a system self-test or calibration after initial use or after prolonged periods of inactivity. Although some monitors support automatic calibration, to ensure data accuracy, it is recommended to perform a manual calibration procedure according to the monitor's instruction manual when replacing a new module or suspecting data anomalies.
2. Correct Connection of Sampling Tubing:
The two metal connectors on the back are for connecting the bypass sampling tubing. Ensure the tubing connection is tight to avoid air leakage, otherwise it will lead to lower or fluctuating measurement values.
3. Prevent Liquid from Entering the Module:
This module is a gas monitoring device; liquids (such as condensation or secretions) must not enter the sampling port. It is recommended to install a water trap (water filter) or anti-condensation device in the sampling tubing, especially when the patient's exhaled gas has high humidity, to prevent liquid backflow and damage to the sensor.
The primary function of this CO2 monitoring module is to monitor the patient's end-tidal carbon dioxide concentration in real time. End-tidal carbon dioxide concentration is a crucial indicator for assessing a patient's ventilation status, helping healthcare professionals determine if the patient's respiratory function is normal and promptly identify abnormalities such as hypoventilation or hyperventilation.