| Model: | 2000976-002 | Component Type: | NIBP Pump Assembly |
|---|---|---|---|
| Material: | Electronic Components, Plastic, Metal | Interface Type: | Flat Ribbon Cable |
| Warranty: | 90 Days | Function: | Blood Pressure Measurement |
| Moq: | 1 | Included Components: | Pump Motor, Solenoid Valves, Pressure Sensor Interface, Circuit Board |
| Product Type: | Medical Replacement Part | Machine Application: | GE DASH 3000/4000/5000 |
| Highlight: | GE DASH3000 NIBP module,DASH5000 blood pressure pump,Non-invasive blood pressure assembly |
||
GE DASH3000 DASH4000 DASH5000 NIBP Module 2000976-002 Non-Invasive Blood Pressure Pump Assembly
This is the non-invasive blood pressure (NIBP) pump module for the GE DASH3000/4000/5000 series monitors, part number 2000976-002. It is a field-replaceable unit (FRU) used for inflation and deflation during blood pressure measurement.
The module includes a roller pump, a solenoid valve, a pressure sensor, and a connecting circuit board, communicating with the monitor's main unit via a flexible flat cable. Its core function is to provide precise pressure control for the blood pressure cuff, ensuring accurate blood pressure measurements.
![]()
| Product Name | NIBP Pump Assembly |
|---|---|
| Model | 2000976-002 |
| Material | Electronic Components, Plastic, Metal |
| Function | Blood Pressure Measurement |
| Interface | Flat Ribbon Cable |
| Machine Application | GE DASH 3000/4000/5000 |
Tip:
Installing this module is straightforward—usually involving removing the monitor's back cover, unplugging the ribbon cable, and unscrewing the mounting screws. However, after installing the new module, we recommend running a "System Self-Test" or "Functional Check" to ensure the air-tightness of the circuit. This small step saves you from future headaches.
1. Function:
Responsible for inflation and deflation in NIBP measurements.
2. Operating Principle:
Controlled by the DAS (Data Acquisition System) board, it pressurizes the cuff via an air pump and slowly deflates the cuff through a control valve, thereby measuring systolic, diastolic, and mean pressure.
3. Troubleshooting:
If the NIBP fails to inflate or the measurement fails, it is recommended to check the pump assembly or related air circuit seals.