logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

GE HD DIFB Board 5194007 REV 6 for High Definition Detector Interface PCB Board Assembly Parts

GE HD DIFB Board 5194007 REV 6 for High Definition Detector Interface PCB Board Assembly Parts

  • GE HD DIFB Board 5194007 REV 6 for High Definition Detector Interface PCB Board Assembly Parts
  • GE HD DIFB Board 5194007 REV 6 for High Definition Detector Interface PCB Board Assembly Parts
  • GE HD DIFB Board 5194007 REV 6 for High Definition Detector Interface PCB Board Assembly Parts
  • GE HD DIFB Board 5194007 REV 6 for High Definition Detector Interface PCB Board Assembly Parts
GE HD DIFB Board 5194007 REV 6 for High Definition Detector Interface PCB Board Assembly Parts
Product Details:
Place of Origin: USA
Brand Name: GE
Model Number: 5194007
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: USD
Packaging Details: Carton Packaging
Payment Terms: T/T,Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: HD DIFB Board MOQ: 1 Pcs
Model: 5194007 Brand: GE
Application: High Definition Detector Color: Green
Express: Fedex, DHL, UPS, Etc Delivery Time: 3-5 Days
Warrenty: 90 Days Condition: Good
Highlight:

GE HD DIFB board replacement

,

Patient monitor interface PCB

,

High definition detector assembly parts

GE HD DIFB Board 5194007 REV 6 for High Definition Detector Interface PCB Board Assembly Parts



Description


DIFB stands for Detector Interface Board. It is mainly used to receive analog electrical signals (converted from X-ray photons) from the CT detector array, convert them into digital signals through high-speed analog-to-digital converters, and transmit them to the back-end image reconstruction unit. It is responsible for coordinating the synchronization of the detector, X-ray tube and rotating rack to ensure that the timing of data collection is accurate when the rack rotates at high speed. It is a key electronic hardware component in GE medical CT equipment and is used to replace and repair HD series detector systems.

 

Features:

- The DIFB board is typically located at the rear of the detector and provides multiple physical interfaces for connecting to the front-end detector module array. It integrates and preprocesses the weak light or electrical signals captured by the detector.

- To support high-definition imaging, it must possess extremely high data transmission bandwidth to process massive amounts of scan data and ensure rapid image reconstruction after scanning.

- CT imaging is highly sensitive to noise. This board is designed with rigorous electromagnetic shielding and low-noise circuitry to ensure that no additional electronic noise is introduced during signal transmission, thereby guaranteeing image clarity and density resolution.


Brand

GE

Application

High Definition Detector

Title

Board

Condition Good
Warranty 90 days
Material

PCB

Color Green
Application Hospital Medical Machine
Payment T/T, Western Union, PayPal
Delivery 3-5 days


GE HD DIFB Board 5194007 REV 6 for High Definition Detector Interface PCB Board Assembly Parts 0


Warranty


Warranty period: 90 days

We provide warranty for both new and used equipment. Different equipment has different warranty periods. You can contact us to check the warranty details.



Delivery Details


Express delivery method: DHL, FedEx, UPS, etc.

Once payment is completed, we will immediately deliver the product to you quickly and safely. And the delivery date is about 3-5 working days, the shipping cost depends on your country and region.

If your delivery date is longer than expected, or you want to know the shipping details, you can contact us at any time.



Quality


Whether it is new equipment or old equipment, our engineers will conduct a comprehensive inspection before arranging delivery, and we have a 3 month warranty period, so you can purchase with confidence.



Warning


1. It's must use the correct electrical outlet to avoid damage or malfunction.

2. Try to avoid long-term storage, especially in high temperature and high humidity environments.

3. Do not use high-temperature, high-pressure vapour or ionizing radiation as disinfection methods.

4. Do not use chloric disinfectant such as chloride, sodium hypochlorite etc.

5. Please keep it away from water and fire.







We also provide other medical equipment and accessories. If you have any other needs or any questions about this product, please feel free to contact us, we will reply you as soon as possible.

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Anna

Tel: 86-15083619413

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.