logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

01.13.32483-01 01.13.107987 01.13.107986 EDAN F200 F300 Fetal Monitor Grounding Wire Assembly 01.13.107988 01.13.32483-01

01.13.32483-01 01.13.107987 01.13.107986 EDAN F200 F300 Fetal Monitor Grounding Wire Assembly 01.13.107988 01.13.32483-01

  • 01.13.32483-01 01.13.107987 01.13.107986 EDAN F200 F300 Fetal Monitor Grounding Wire Assembly 01.13.107988 01.13.32483-01
  • 01.13.32483-01 01.13.107987 01.13.107986 EDAN F200 F300 Fetal Monitor Grounding Wire Assembly 01.13.107988 01.13.32483-01
  • 01.13.32483-01 01.13.107987 01.13.107986 EDAN F200 F300 Fetal Monitor Grounding Wire Assembly 01.13.107988 01.13.32483-01
  • 01.13.32483-01 01.13.107987 01.13.107986 EDAN F200 F300 Fetal Monitor Grounding Wire Assembly 01.13.107988 01.13.32483-01
  • 01.13.32483-01 01.13.107987 01.13.107986 EDAN F200 F300 Fetal Monitor Grounding Wire Assembly 01.13.107988 01.13.32483-01
  • 01.13.32483-01 01.13.107987 01.13.107986 EDAN F200 F300 Fetal Monitor Grounding Wire Assembly 01.13.107988 01.13.32483-01
01.13.32483-01 01.13.107987 01.13.107986 EDAN F200 F300 Fetal Monitor Grounding Wire Assembly 01.13.107988 01.13.32483-01
Product Details:
Brand Name: EDAN
Model Number: F200 F300
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,Paypal
Contact Now
Detailed Product Description
Product Name: EDAN F200, F300 Fetal Monitor Conductor Type: High-purity Copper
Machine Application: PVC, Green/Yellow Color Coded Grounding Resistance: ≤ 0.2Ω
Contact Resistance: ≤ 10mΩ At Terminals Safety Standard: IEC 60601-1
Function: Transmits Vital Signs Data Operating Temperature: 0°C - 40°C
Certification: Medical Grade Conductor Cross-section: ≥ 1.5 Mm²
Highlight:

EDAN fetal monitor grounding wire

,

F200 F300 monitor grounding assembly

,

patient monitor grounding wire assembly

01.13.32483-01 01.13.107987 01.13.107986 EDAN F200 F300 Fetal Monitor Grounding Wire Assembly 01.13.107988 01.13.32483-01

 

Grounding Wire Assembly Introduction

 

These grounding wire assemblies are original factory safety grounding accessories specifically designed for the EDAN F200 and F300 fetal monitors. They are primarily used for a safe connection between the internal circuitry and the casing of the device. With a simple and reliable structure, they are specifically adapted to the internal grounding points of these two models. These small components are crucial for ensuring stable operation, enhancing anti-interference capabilities, and guaranteeing safe use. When the device experiences significant signal interference, waveform drift, leakage current induction, or abnormal alarms, replacing or inspecting the grounding wires can effectively resolve the problem.

 

01.13.32483-01 01.13.107987 01.13.107986 EDAN F200 F300 Fetal Monitor Grounding Wire Assembly 01.13.107988 01.13.32483-01 001.13.32483-01 01.13.107987 01.13.107986 EDAN F200 F300 Fetal Monitor Grounding Wire Assembly 01.13.107988 01.13.32483-01 1

 

Main Functions:

 

1. Ensures reliable grounding between the internal circuitry and the outer casing, reducing the risk of leakage and ensuring the safety of patients and medical staff.

 

2. Effectively shields against external electromagnetic interference, resulting in more stable waveforms and more accurate data for monitoring fetal heart rate, uterine contractions.

 

3. Dissipates static electricity generated during equipment operation, preventing electrostatic discharge damage to precision components such as the motherboard and probe interfaces.

 

4. Enhances the overall electrical safety of the device, complying with medical equipment grounding standards and reducing false alarms and signal anomalies.

 

Grounding wire position

 

01.13.32483-01 01.13.107987 01.13.107986 EDAN F200 F300 Fetal Monitor Grounding Wire Assembly 01.13.107988 01.13.32483-01 2

J1 is the equipotential grounding point that connects to the ground.

 

Safety Requirements

 

• Equipment and devices that connect to the monitor should form an equipotential body to ensure effective grounding.

 

• Take precautions against static electricity during operation to avoid damaging the internal circuit board.

 

• The terminals must be tightened securely to ensure good contact,do not allow them to become loose or have intermittent connections.

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: +8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.