Parameter Board For Biolight Q5 Patient Monitor Includes NIBP 12032667-1 FH-Z210131202

Parameter Board For Biolight Q5 Patient Monitor Includes NIBP 12032667-1 FH-Z210131202

  • Parameter Board For Biolight Q5 Patient Monitor Includes NIBP 12032667-1 FH-Z210131202
  • Parameter Board For Biolight Q5 Patient Monitor Includes NIBP 12032667-1 FH-Z210131202
  • Parameter Board For Biolight Q5 Patient Monitor Includes NIBP 12032667-1 FH-Z210131202
  • Parameter Board For Biolight Q5 Patient Monitor Includes NIBP 12032667-1 FH-Z210131202
  • Parameter Board For Biolight Q5 Patient Monitor Includes NIBP 12032667-1 FH-Z210131202
  • Parameter Board For Biolight Q5 Patient Monitor Includes NIBP 12032667-1 FH-Z210131202
Parameter Board For Biolight Q5 Patient Monitor Includes NIBP 12032667-1 FH-Z210131202
Product Details:
Brand Name: Biolight
Model Number: Q5
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,Paypal
Contact Now
Detailed Product Description
Compatible Monitor: Biolight Q5 Part Number: 12032667-1 FH-Z210131202
Board Type: Multi-parameter Board With NIBP Module Supported Parameters: NIBP/ECG/SpO₂/TEMP
Patient Populations: Adult, Pediatric, Neonatal Safety Features: Dual Overpressure Protection
Component Quality: Medical-grade Sippment: DHL, EMS, UPS, FedEx
Material: FR4 PCB, Precision Electronic Components Warranty: 90 Days
Highlight:

Biolight Q5 parameter board

,

Patient monitor NIBP board

,

Biolight monitor replacement part

Parameter Board For Biolight Q5 Patient Monitor Includes NIBP 12032667-1 FH-Z210131202

 

 

Product Description

 

This product is a multi-parameter board assembly specifically designed for the Q5 patient monitor, integrating the complete NIBP (Non-Invasive Blood Pressure) measurement module along with supporting circuitry for other physiological parameters. The board features a precision-engineered PCB with dedicated sections for pneumatic control, pressure sensing, and signal processing. Its layout includes high-quality electronic components such as pressure transducers, solenoid valves, and analog-to-digital converters, all arranged for optimal signal integrity. The NIBP section operates on the oscillometric measurement principle, controlling cuff inflation and deflation while analyzing pressure oscillations to determine systolic, diastolic, and mean arterial pressure values. This parameter board serves as the measurement control center for vital signs acquisition, supporting adult, pediatric, and neonatal patient populations with clinically validated accuracy.

 

Parameter Board For Biolight Q5 Patient Monitor Includes NIBP 12032667-1 FH-Z210131202 0

 

Biolight Q5 parameters

 

Including ECG(3-lead or 5-lead or 12-lead selectable), arrhythmia detection,ST segmentanalysis, Heart Rate (HR), Respiration Rate (RESP), Temperature (TEMP),Pulse Oxygen Saturation (SpO2), Pulse Rate (PR), Non-invasive Blood Pressure(NIBP), Invasive Blood Pressure (IBP),Carbon dioxide (CO2), Anesthetic GasAG)

 

Parameter Specifications:

 

ECG

• Leads: I, II, III, aVR, aVL, aVF, V-

• Mode: 3-leads, 5-leads

• Gains: 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV, 40mm/mV, auto

• Scanning Speed: 12.5mm/s, 25mm/s, 50mm/s

• Heart Rate Range: Adult: 10~300bpm Child &Neonate: 10~350bpm

•Accuracy: ±1bpm or ±1% whichever is greater

 

NIBP

• Operation Modes: Automatic Oscillometry

• Range: Adult: 10 ~270mmHg Child: 10 ~235mmHg Neonate: 10 ~135mmHg

• Measurement: Systolic Pressure/Diastolic Pressure/Mean Pressure

• Unit: mmHg, kPa

• Pulse rate range: 40 ~240bpm

 

SpO2 (Pulse Oximetry)

• Range: 0 ~100%

• Accuracy: ±2% (70% ~100%); Unspecified (0 ~69%)

• Range & Accuracy of Pulse Rate: 25 ~254bpm ±1bpm or ±1% whichever is greater

 

Parameter Alarm

 

You can configure parameter alarms in the dedicated settings menu for each parameter. Within the menu of a specific parameter, you can view and adjust the alarm limits and alarm status, and the alarm settings for different parameters are independent of each other. You can also set parameter alarms by pressing the 【Main Menu】 smartkey and selecting 【Alm Setup】.

 

For parameters with the alarm switch set to ON, an alarm will be triggered once the parameter value exceeds the preset alarm limit. When an alarm occurs, the following actions will be executed:

  1. Audible and visual alarms will be activated according to the alarm level.

  2. The corresponding alarm message will be displayed in the physiological alarm area.

  3. The value of the parameter in alarm will flash continuously.

  4. If alarm recording is enabled, the recorder will start recording alarm data at the preset interval.

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: +8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.