logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsUsed Patient Monitor

Biocare IM 12 Multi-Parameter Patient Monitor Used With Good Condition

Biocare IM 12 Multi-Parameter Patient Monitor Used With Good Condition

  • Biocare IM 12 Multi-Parameter Patient Monitor Used With Good Condition
  • Biocare IM 12 Multi-Parameter Patient Monitor Used With Good Condition
  • Biocare IM 12 Multi-Parameter Patient Monitor Used With Good Condition
  • Biocare IM 12 Multi-Parameter Patient Monitor Used With Good Condition
  • Biocare IM 12 Multi-Parameter Patient Monitor Used With Good Condition
  • Biocare IM 12 Multi-Parameter Patient Monitor Used With Good Condition
Biocare IM 12 Multi-Parameter Patient Monitor Used With Good Condition
Product Details:
Brand Name: Biocare
Model Number: IM 12
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T,Western Union,Paypal
Contact Now
Detailed Product Description
Model: IM 12 Battery Life: 10 H
Screen Size: 12.1 In Measured Parameter: ECG, NIBP, EtCO2,Temp And So On
(AC) Input Voltage: 100 V~240 V Input Power: 75 VA
Operating Temperature: 0℃~50℃ (32℉~122℉) Waveforms: Up To 13
Technology: Pulse Wave Analysis Applications: Transport, Clinical, Hemodynamic
Highlight:

used Biocare IM 12 patient monitor

,

multi-parameter patient monitor with warranty

,

Biocare IM 12 medical monitor

Biocare IM 12 Multi-Parameter Patient Monitor Used With Good Condition


Introduction:


This patient monitor is intended for continuous monitoring of a fixed set of physiological parameters for single adult, pediatric, and neonatal patients. The monitored parameters include electrocardiography (ECG), respiration (Resp), temperature (Temp), pulse oximetry (SpO2), pulse rate (PR), non-invasive blood pressure (NIBP), invasive blood pressure (IBP), carbon dioxide (CO2), oxygen (O2), AG , as well as CSI/IoC .


Overview:


Biocare IM 12 Multi-Parameter Patient Monitor Used With Good Condition

1. Physiological Alarm Indicator Lamp

2. Technical Alarm Indicator Lamp

3. Display Screen

Biocare IM 12 Multi-Parameter Patient Monitor Used With Good ConditionBiocare IM 12 Multi-Parameter Patient Monitor Used With Good Condition

1. Parameter Interfaces

 IBP1, IBP2—invasive blood pressure interface.

 T1, T2—body temperature probe interface.

 NIBP— non-invasive blood pressure interface.

 SpO2— blood oxygen saturation probe interface.

 ECG— electrocardiograph lead interface.


2. Battery Door


3. Recorder


Functions:


  • It is equipped with audible and visual alarms to alert users of any abnormal patient conditions or equipment issues.
  • It supports the display, review, storage, and transmission of real-time monitoring data.
  • It provides multiple input methods, including physical buttons, control knobs, and a touchscreen.
  • It features both wired and wireless ports for connection to the CMS system.
  • It includes a dedicated port for integration with the nurse call system.
  • Optional analog waveform output is available for ECG and IBP signals.
  • It is equipped with a VGA port to support dual-screen display.
  • System and program upgrades can be completed easily through the USB port.

Specifications


(AC) Input Voltage  100 V~240 V
Input Power  75 VA
Frequency  50 Hz/60 Hz (Allowable frequency error ±1Hz)
Fuse  3.15A/250V
Safety Classification  Class I, Type BF, CF
Weight  About 5.5 kg
Size (L×W×H)  310 mm×163 mm×285 mm
Display Type  TFT LCD Screen
Battery Type Rechargeable lithium battery
Recorder Type  Thermal array recorder


Notice


1. Pre-Power-On Check: Before each use, connect the power supply (confirm voltage compatibility 100V~240V, 50Hz/60Hz), start the device to complete the system self-test, and connect to the patient only after the self-test indicates "normal". Simultaneously check the device exterior for damage, ensure the leads, sensors, and power cord are intact and not exposed, and check for loose connections to avoid poor contact leading to monitoring abnormalities.

2. Regular Maintenance: Every 3-6 months, a comprehensive inspection and parameter calibration of the device is required, focusing on sensor sensitivity, battery life, and gas path sealing (if blood pressure monitoring is supported) to ensure accurate monitoring data. If excessive parameter deviations, alarm malfunctions, screen flickering, or other abnormalities are found, immediately stop the device for troubleshooting. Do not continue use; contact a professional for repair if necessary.

3. Proper Storage: When not in use, the device should be placed in a dry, well-ventilated environment free from corrosive gases and strong electromagnetic interference sources. Avoid high temperature, high humidity, or direct sunlight.


FAQ:


1. Can your accessories be compatible with the English version of imported medical equipment?

Yes. The English version of imported equipment has identical hardware specifications to the original version, and our accessories are fully compatible without any compatibility issues.


2. Are the accessories for the English version of imported equipment interchangeable with those for the Chinese version?

Yes, they are. The hardware specifications are identical, allowing the accessories to be used interchangeably without requiring additional matching.


3. What should I do if the accessory matches the device but fails to charge properly?

Check that the charging port is in good contact and that the charger is functioning correctly. If charging still does not work, contact our technical team to arrange replacement of the accessory.


4. Why can't the accessory charge?

Possible causes include: damaged charging port, internal accessory failure, or incompatible charger. We will assist you in troubleshooting.


5. Are your accessories compatible with portable ultrasound devices?

Yes. We offer specialized accessories designed for portable ultrasound devices, which are compact and lightweight, compatible with various types of portable ultrasound equipment.


Biocare IM 12 Multi-Parameter Patient Monitor Used With Good Condition Biocare IM 12 Multi-Parameter Patient Monitor Used With Good Condition
90 Day Warranty                             SGS ceryification

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: +8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.