logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

Safety Assured EDAN F2 Fetal Monitor Grounding Wire Assembly 01.13.32483-01

Safety Assured EDAN F2 Fetal Monitor Grounding Wire Assembly 01.13.32483-01

  • Safety Assured EDAN F2 Fetal Monitor Grounding Wire Assembly 01.13.32483-01
  • Safety Assured EDAN F2 Fetal Monitor Grounding Wire Assembly 01.13.32483-01
  • Safety Assured EDAN F2 Fetal Monitor Grounding Wire Assembly 01.13.32483-01
  • Safety Assured EDAN F2 Fetal Monitor Grounding Wire Assembly 01.13.32483-01
Safety Assured EDAN F2 Fetal Monitor Grounding Wire Assembly 01.13.32483-01
Product Details:
Place of Origin: China
Brand Name: Edan
Certification: CE
Model Number: F2
Payment & Shipping Terms:
Minimum Order Quantity: 1 Piece
Price: USD
Packaging Details: Carton
Delivery Time: 3-5 working days
Payment Terms: T/T,Western Union,Paypal
Contact Now
Detailed Product Description
Product Name: Grounding Wire Assembly PN: 01.13.32483-01
Cable Length: 20 Cm Condition: Tested
Compatible With: F2 Fetal Monitor Color: Yellow/green
Warranty: 90 Days Shipping By: Air
Delivery Time: 7-15 Days MOQ: 1PC
Highlight:

EDAN F2 fetal monitor grounding wire

,

safety assured fetal monitor parts

,

patient monitor grounding wire assembly

Safety Assured EDAN F2 Fetal Monitor Grounding Wire Assembly 01.13.32483-01

This is one of the important internal connection cables for the F2 fetal heart rate monitor. This cable is a grounding assembly, and the part number 01.13.32483-01 is printed on it for quick identification during maintenance and cable replacement.

This grounding assembly differs slightly from ordinary cables in its connectors. Both ends of this cable are metal segments, which can be connected to the device's grounding terminal and the power board, respectively.

The cable uses a yellow-green dual-color design, and the conductors are multi-strand tinned copper cores, providing excellent conductivity. The outer layer of the conductors is PVC insulation, offering good insulation performance and aging resistance.

Grounding Replacement Steps

1. First, disconnect the device from power and release any residual electrical charge.

2. Remove the device casing and locate the connection position of the old grounding assembly.

3. Disconnect the terminals of the old wires one by one, and record the corresponding position of each wire.

4. Connect the new grounding component's wiring to the corresponding location according to the recorded positions.

5. Tighten all screws to ensure secure terminal contact and prevent loosening.

6. Use a multimeter to test the grounding resistance. Once confirmed to meet safety standards, reinstall the casing.

Technical Specifications

Product name

Grounding Wire Assembly

PN

01.13.32483-01 

Type

Monitor parts

Cable length

20CM

Color

Yellow/Green

Material

PVC

MOQ

1 Piece

Warranty

90 days

Weight

Light

Product Images
Safety Assured EDAN F2 Fetal Monitor Grounding Wire Assembly 01.13.32483-01 0
Safety Assured EDAN F2 Fetal Monitor Grounding Wire Assembly 01.13.32483-01 1

FAQ

Q1: The device receives a leakage current alarm during operation, and the device casing is electrified. Is this a grounding fault?

A1: First, check if the two grounding wire connections are loose. If not, use a professional multimeter to check if the resistance between the device casing and the ground is less than 0.5Ω. If the resistance is too high, the grounding component needs to be replaced.

Q2: During normal monitoring, the F2 monitor experiences signal interference, causing abnormal waveforms. What could be the cause?

A2: Check if the internal connecting cables are damaged. Damaged cables can impair anti-interference capabilities, leading to abnormal data transmission. If the cables are damaged, replace them and re-monitor.

Q3: The grounding wire connection is worn or aged. Does it need to be replaced?

A3: If the grounding wire connection is severely worn or aged, it is recommended to replace it promptly to prevent leakage current during device use.

Ordering Information
Payment Methods Bank Transfer / PayPal / Western Union
Shipping Methods DHL / FedEx

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Bella

Tel: 86-18879075074

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.