logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

Biolight BLT Q5 Patient Monitor Three-prong Power Supply and Grounding Wire Assembly

Biolight BLT Q5 Patient Monitor Three-prong Power Supply and Grounding Wire Assembly

  • Biolight BLT Q5 Patient Monitor Three-prong Power Supply and Grounding Wire Assembly
  • Biolight BLT Q5 Patient Monitor Three-prong Power Supply and Grounding Wire Assembly
  • Biolight BLT Q5 Patient Monitor Three-prong Power Supply and Grounding Wire Assembly
  • Biolight BLT Q5 Patient Monitor Three-prong Power Supply and Grounding Wire Assembly
  • Biolight BLT Q5 Patient Monitor Three-prong Power Supply and Grounding Wire Assembly
  • Biolight BLT Q5 Patient Monitor Three-prong Power Supply and Grounding Wire Assembly
Biolight BLT Q5 Patient Monitor Three-prong Power Supply and Grounding Wire Assembly
Product Details:
Brand Name: Biolight
Model Number: Q5
Payment & Shipping Terms:
Minimum Order Quantity: 1 Piece
Price: USD
Packaging Details: Standard Export Packing
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union, Paypal
Supply Ability: In stock
Contact Now
Detailed Product Description
Brand: Biolight Product Name: Three-prong Power Supply And Grounding Wire Assembly
Model: Q5 Use For: Biolight BLT Q5 Patient Monitor
Condition: Used In Good Working Warranty: 90 Days
Delivery Method: DHL, FEDEX, UPS, Etc. Inventory: In Stock
Payment Method: Paypal,T/T,Western Union Method Of Transport: Expressage
Material: Metal MOQ: 1 Piece
Highlight:

Biolight BLT Q5 power supply

,

patient monitor grounding wire

,

three-prong power cord

Biolight BLT Q5 Patient Monitor Three-prong Power Supply Assembly Spare part

 
Brief Description
 

The three-prong power supply , consisting of three three-core wires of different colors.The three-core power and grounding assembly consists of three three-core wires of different colors. Different colored wires are inserted into different connectors.This power supply is made of metal and is silver in color. It has screw holes for fixing it to the device to prevent it from becoming loose or making poor contact.

The three-prong Power Supply is a standard three-prong plug (live wire L, neutral wire N, ground wire E), and the other end is usually three independent wires with terminals (brown/red - L, blue/black - N, yellow-green - E).

 
The main functions of a three-prong power supply:
Live Wire: Conducts current to the equipment.
Neutral Wire: Forms a current loop.
Ground Wire: Provides safe grounding, preventing electric shock or equipment damage.
Core function: Safe grounding. If the internal insulation of the monitor fails, causing the metal casing to become live, the ground wire will directly conduct the current to the earth, preventing electric shock to the user.

 

Three-prong Power Supply  Assembly Installation Steps

 

1. Disconnect all power. Prepare a suitable screwdriver and locate the power module area on the back of the Q5 monitor.

 

2. Open the Q5 Monitor Housing

Using the appropriate screwdriver, remove all screws securing the back cover and carefully remove the back cover to expose the internal structure.

 

3. Locate the Power Connection Points

Locate the power module inside the device. It is usually a separate metal box or circuit board with clear markings.

 

L or LINE: Live wire terminal

 

N or NEUTRAL: Neutral wire terminal

 

PE or ⏚ or GND: Protective grounding terminal

 

4. Connect the Power Wire and Grounding Wire

 

Connect the yellow-green wire in the power wire assembly to the terminal marked with the PE or grounding symbol.

 

Ensure the connection is very secure. This is the most important safety step.

 

Connecting the Live and Neutral Wires:

 

Connect the brown (or red) wire to the L terminal.

 

Connect the blue (or black) wire to the N terminal. Tightening and Inspection:

 

Use appropriate tools to tighten the wire clamps on each terminal, ensuring the wires are secure.

 

Gently pull on each wire to check for a firm hold.

 

5. Reinstall the casing and perform a final inspection:

 

Carefully inspect the interior for any remaining tools or screws.

 

Reinstall the back cover and tighten all screws.

 

6. Power-on Test and Verification:

 

Plug the three-pin power connector into a properly grounded wall outlet.

 

Turn on the monitor's main power switch.

 

Observe whether the device starts normally, whether the screen display is normal, and whether there are any abnormal sounds or smells.

 
► Specifications
 

Part NumberBLT Q5
Brand nameBiolight
Product nameThree-prong Power Supply and Grounding Wire
MOQ1 Piece
Warranty90 Days
Payment MethodT/T ,Paypal ,Western Union
Use forBLT Q5 Patient Monitor
Product EdgeOriginal,Advanced equipment
Delivery3-5 Working Days
Power Supply SourceElectric
Payment TermsFull Before Shippment
Delivery MethodDHL ,Fedex ,UPS
Stock SituationStock available
MaterialMetal
Method of TransportExpressage
Product CharacteristicFunctional,Durable in use

 
Detailed Photos
 
Biolight BLT Q5 Patient Monitor Three-prong Power Supply and Grounding Wire Assembly 0
 
Biolight BLT Q5 Patient Monitor Three-prong Power Supply and Grounding Wire Assembly 1
 

Our company

CWT Technology HK CO. LTD , located in Guangzhou, China, is a leading exporter of used medical equipment in China. We sell and repair used medical equipment such as patient monitors, electrocardiographs, defibrillators, spare parts and accessories.

 
Warning:
1. Ensure proper grounding: Poor grounding of the socket may render the three-prong plug ineffective.
2. Avoid forced modifications: Do not arbitrarily remove the grounding prong or use adapters, as this may cause safety hazards.
3. Regular inspection: Old wiring or sockets may have grounding failures and require regular inspection.
 
FAQ:

 

Q1: How can I pay for the product ?

A1:T/T, Western Union, PayPal are all available.

 

Q2:What is the product warranty period?

A2: All products have a 90-day warranty, we can replace or refund you within the warranty period.

 

Q3:How long will it take to receive this product?

A3:Normally, it will take 5-8 business days.

 

Q4:Can an engineer provide guidance on installation and use?

A4:Sure, our engineers will provide instructional videos; please feel free to contact us anytime with any questions.

 
If you want to explore more details about Biolight BLT Q5 Patient Monitor Three-prong Power Supply assembly Spare Part, please contact me at any time, looking forward to your early inquiry.
 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Mia

Tel: 86-15779588554

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.