logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

Mindray Datascope Passport 2 Monitor Power Module Back Cover 019800005OB Equipment Protective Casing

Mindray Datascope Passport 2 Monitor Power Module Back Cover 019800005OB Equipment Protective Casing

  • Mindray Datascope Passport 2 Monitor Power Module Back Cover  019800005OB Equipment Protective Casing
  • Mindray Datascope Passport 2 Monitor Power Module Back Cover  019800005OB Equipment Protective Casing
  • Mindray Datascope Passport 2 Monitor Power Module Back Cover  019800005OB Equipment Protective Casing
  • Mindray Datascope Passport 2 Monitor Power Module Back Cover  019800005OB Equipment Protective Casing
  • Mindray Datascope Passport 2 Monitor Power Module Back Cover  019800005OB Equipment Protective Casing
  • Mindray Datascope Passport 2 Monitor Power Module Back Cover  019800005OB Equipment Protective Casing
Mindray Datascope Passport 2 Monitor Power Module Back Cover  019800005OB Equipment Protective Casing
Product Details:
Brand Name: Mindray
Model Number: 019800005OB
Payment & Shipping Terms:
Minimum Order Quantity: 1
Payment Terms: T/T, Western Union,Paypal
Contact Now
Detailed Product Description
Product Name Monitor: Power Module Back Cover Material: Medical-grade ABS Plastic
Compatible: Passport 2 Installation Position: Power Module Rear Side
Operating Temperature: -10- 40°C PN: 019800005OB
Weight: Approx 200g Warranty: 90 Days
Sippment: DHL, EMS, UPS, FedEx MOQ: 1
Highlight:

Mindray Datascope Passport 2 monitor power module

,

Patient monitor protective casing

,

Monitor back cover with warranty

Mindray Datascope Passport 2 Monitor Power Module Back Cover 019800005OB Equipment Protective Casing

 

Product Type Power Module Back Cover
Part No   019800005OB
Fixing Method 4 pre-drilled screw holes
Function Protects power components
Condition used with good working
Material Medical-grade ABS plastic
Applicable Type Passport 2
Color white shell
MOQ 1pcs
Advantages Precise fit with power module, medical-grade insulation
Warranty 90 days

 

 

Mindray Datascope Passport 2 Monitor Power Module Back Cover  019800005OB Equipment Protective Casing 0

 

Product Overview

 

When you need to maintain or servicing your Mindray Datascope Passport 2 monitor, the power module back cover (part number: 019800005OB) is a critical housing component. As the monitor's main unit's safety backplate, it is specifically designed to encapsulate and protect the delicate internal power conversion module and core circuitry.

 

It is a white plastic housing with a copper-colored heat sink embedded inside. It also features pre-drilled holes for the power module interface and a snap-fit ​​mechanism for engaging the module. Protecting the internal high voltage and sensitive components from the external environment is fundamental to ensuring stable power supply and safe operation of the Passport 2.

Mindray Datascope Passport 2 Monitor Power Module Back Cover  019800005OB Equipment Protective Casing 1

No 45. AC Receptacle
Insert an AC power cord into this connector.
CAUTION: Use only Mindray DS supplied power cords, or if a substitute is necessary, use only hospital grade power cords.


No 46. Equipotential lug
Provides Equipotential grounding of hospital equipment

 

Advantages:

 

Its primary function is to protect the stable operation of the power module.

 

1. External Protection: The outer shell is made of anti-aging medical-grade plastic.It shields the power module from dust and minor impacts in the clinical environment, preventing direct exposure and damage to the internal components.

 

2. Auxiliary Heat Dissipation: The copper-colored heat sink on the inner side helps dissipate heat generated during operation, maintaining a stable operating temperature.

 

3. Precise Fit: It aligns the power module's interface with pre-drilled holes and secures the module components with clips to prevent loosening or misalignment during use.

 

Disassembly Steps:

 

1. Preparation: Ensure the device is powered off. Prepare appropriate tools, typically including a set of matching Phillips screwdrivers.

 

2. Remove External Screws: Locate all screws securing the back cover. When using a screwdriver, ensure the tip is fully engaged in the screw slot before applying even pressure to prevent slippage and damage.

 

3. Loosen the Back Cover: It is recommended to loosen multiple screws diagonally, alternating turns, one turn at a time to evenly release stress and prevent deformation of the back cover.

 

4. Remove the Back Cover: After removing all securing screws, hold the device and back cover firmly with your hands and carefully separate them. Check for any connecting cables; if present, disconnect them first.

 

Notice:

 

1. Always disconnect the monitor's power supply before disassembly or assembly to avoid touching internal components while the power is on;

 

2. Do not use metal tools to pry open the clips, and do not forcefully pry open the back cover to prevent the plastic clips from breaking or the casing from deforming;

 

3. Clean only with a dry, soft cloth. Do not use liquid cleaners, especially avoid letting liquid seep into the inner heat sink area;

 

4. After installation, always check that the back cover is securely fastened. A loose cover will not only compromise protection but may also affect the heat dissipation of the power module.

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: +8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.