logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

Mindray Datascope Passport 2 Monitor Fan ICFAN 12V 0.1A S0510-12 For Medical Device Cooling

Mindray Datascope Passport 2 Monitor Fan ICFAN 12V 0.1A S0510-12 For Medical Device Cooling

  • Mindray Datascope Passport 2 Monitor Fan ICFAN 12V 0.1A S0510-12 For Medical Device Cooling
  • Mindray Datascope Passport 2 Monitor Fan ICFAN 12V 0.1A S0510-12 For Medical Device Cooling
  • Mindray Datascope Passport 2 Monitor Fan ICFAN 12V 0.1A S0510-12 For Medical Device Cooling
  • Mindray Datascope Passport 2 Monitor Fan ICFAN 12V 0.1A S0510-12 For Medical Device Cooling
  • Mindray Datascope Passport 2 Monitor Fan ICFAN 12V 0.1A S0510-12 For Medical Device Cooling
Mindray Datascope Passport 2 Monitor Fan ICFAN 12V 0.1A S0510-12 For Medical Device Cooling
Product Details:
Brand Name: Mindray
Model Number: S0510-12
Payment & Shipping Terms:
Minimum Order Quantity: 1
Contact Now
Detailed Product Description
Product Name: Fan Operating Voltage: DC 12V
Operating Current: 0.1A Airflow Rate: 5.8 CFM
Noise Level: ≤25dB Operating Temperature Range: -5℃ To 60℃
MOQ: 1pcs Warranty: 90 Days
Condition: Used, Excellet Payment Terms: T/T(wire Transfer), Western Union, Paypal
Highlight:

Mindray Datascope Passport 2 monitor fan

,

medical device cooling fan 12V

,

patient monitor replacement fan with warranty

1.Product Introduction

 

This fan, model ICFAN 12V 0.1A S0510-121, is a crucial component inside the Mindray Datascope Passport 2 patient monitor. During prolonged continuous operation, the monitor's internal processor, power supply, and other modules generate heat. The fan's primary function is to continuously and stably expel this hot air, ensuring the internal temperature of the machine remains within a safe and reasonable range.

Mindray Datascope Passport 2 Monitor Fan ICFAN 12V 0.1A S0510-12 For Medical Device Cooling 0

2.Functions & Advantages

 

• Low power consumption and efficiency: With a current draw of only 0.1A, it provides effective heat dissipation without adding unnecessary load to the monitor's power supply.

 

• Stable operation: Continuous heat dissipation effectively prevents the monitor's motherboard, power module, and other core components from overheating, thus preventing accelerated aging or sudden failure. Stable heat dissipation indirectly supports the accuracy and waveform stability of the monitor's data when monitoring parameters such as ECG, blood oxygen, and blood pressure.

 

• Quiet operation considerations: Taking into account the noise control requirements of clinical environments (especially wards), this fan optimizes operating noise while ensuring airflow, avoiding interference with patients and medical staff.

 

3.Fan Controller

 

We condition the digital control signal from the 86OT I/O pin (configured as an output) using resistors R5 and capacitor C7. This conditioned signal then goes to the gate of transistor Q1, which handles the fan’s drive control. The fan uses low-side control, with its return line connected to the source pin of the FET. A 30-ohm resistor (R1) is connected in series with the 12V2 supply; this resistor limits the fan voltage to approximately 9V and reduces fan noise. Typically, the fan draws 100mA of current when operating at 12VDC.

Fan Control:

The cooling fan is ON when the unit is powered from external power.

The cooling fan is OFF when the unit is powered from the internal batteries.

 

4.Fan-Fault Sense

 

To reduce the tachometer pulses from the fan, we connect the SENSE input (pin 5 of U2) to a voltage divider network composed of resistors R5 and R30. During normal fan operation, short interruptions in the fan current generate pulses that feed into this sense resistor network. A fault is present if the device is not in Shutdown mode and no pulses are detected at the SENSE input. The sense network must reduce the pulse amplitude to meet the TC646’s requirement: a minimum of 90mV at pin 5.

Cooling Fan Failure: A cooling fan failure indicates either an over-temperature condition or a detected fan malfunction while the unit is running on AC power. Call for service.

 

5. Fan dust filter maintenance

 

The fan dust filter should be checked and cleaned , at least once every two months. Follow these steps for cleaning:

 

• Locate fan on front panel.

• Remove the filter by pulling the dust filter cover.

• Remove the dust from the filter.

• Let the filter soak in a mild detergent solution.

• Rinse the filter thoroughly and allow it to dry completely before reinstallation.

 

CAUTION: If the fan’s dust filter is uncleanable or damaged, replace it with the specified part (part number: 0378-00-0040). Using any other type of filter may impair cooling efficiency and cause damage to the Gas Module.

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: +8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.