logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

Original Biocare PM-900 Monitor SpO2 Board FM-QSZ-I Used-Good Condition PCB Pulse Oximetry Board

Original Biocare PM-900 Monitor SpO2 Board FM-QSZ-I Used-Good Condition PCB Pulse Oximetry Board

  • Original Biocare PM-900 Monitor SpO2 Board FM-QSZ-I Used-Good Condition PCB Pulse Oximetry Board
  • Original Biocare PM-900 Monitor SpO2 Board FM-QSZ-I Used-Good Condition PCB Pulse Oximetry Board
  • Original Biocare PM-900 Monitor SpO2 Board FM-QSZ-I Used-Good Condition PCB Pulse Oximetry Board
  • Original Biocare PM-900 Monitor SpO2 Board FM-QSZ-I Used-Good Condition PCB Pulse Oximetry Board
Original Biocare PM-900 Monitor SpO2 Board FM-QSZ-I Used-Good Condition PCB Pulse Oximetry Board
Product Details:
Place of Origin: China
Brand Name: Biocare
Model Number: PM-900
Payment & Shipping Terms:
Minimum Order Quantity: 1 Piece
Price: USD
Packaging Details: Carton
Delivery Time: 3-5 working days
Payment Terms: T/T,Western Union,Paypal
Contact Now
Detailed Product Description
Product Name: VGA Board Model: 02049180-01
Condition: Original,used- Good Brand: Biocare
Compatible With: PM-900 MONITOR Material: PCB Board +Metal
Shipping: Within 3-5 Days Afted The Payment Package: 1pc/carton
MOQ: 1 PC Shipping By: Air
Highlight:

Original SpO2 Board

,

Used-Good Condition Pulse Oximetry Board

,

FM-QSZ-I Model PCB SPO2 Board

Original Biocare PM-900 monitor SpO2 board FM-QSZ-I with good condition PCB SPO2 board for Monitor

The Biocare PM-900 monitor's SpO2 board is the original pulse oximetry board for the monitor. The model number is DM-QSZ-I. This board is a module responsible for the monitor's pulse oximetry data acquisition and signal processing. It's an original part salvaged from a disassembled unit, but it has been used before. While its appearance isn't perfect, engineers have tested it and confirmed that it's one of the main data processing modules for the Biocare PM-900 monitor, playing a crucial role in the monitor's pulse oximetry data acquisition.

Key Features

  1. 1. Pulse Oxidation Signal Acquisition: It receives raw physiological signals from the pulse oximeter sensor, amplifies, filters, and converts these signals, and then transmits them to the Biocare PM-900 monitor's mainboard for further data processing.

    2. Signal Processing: The FM-QSZ-I pulse oximeter board is equipped with a high-precision chip that converts the raw data into physiological data such as SpO2 and PR, helping medical staff to more intuitively understand the patient's vital signs and improve clinical efficiency.

    3. Data Transmission: The FM-QSZ-I pulse oximeter board transmits the processed pulse oximetry parameters to the monitor's mainboard, ultimately displaying the corresponding values ​​and waveforms on the screen.

    1. Sensor Compatibility: As seen in the detailed diagram of the pulse oximeter, there is a white interface area in the upper right corner of the circuit board. This is for connecting the sensor. The FM-QSZ-I pulse oximeter is compatible with the pulse oximeter sensor that comes with the PM-900, enabling signal matching and power management between the sensor and the device.

Technical Specifications

Product name

SpO2 board

Model

FM-QSZ-I

Machine Model

Biocare PM-900 monitor

Function

Blood oxygen data processing

Monitoring parameters

SpO, PR

Condition

Used, Original

Material

PCB Board

Delivery

By DHL,FedEx or UPS

MOQ

1 piece

Package

1pc/carton

Color

Green

Product Images
FAQ

Q1: The monitor displays "No Signal" for blood oxygen data. Is this a problem with the module board?

A1: There are multiple possible causes, which can be checked one by one. First, check simple connections such as whether the cables and plugs are inserted or making good contact. If all connections are normal, check if the blood oxygen sensor is firmly inserted and if the probe is making good contact. If the sensor is normal and there is still no signal after restarting the device, try replacing the module board no signal is often related to a fault in the module board's signal acquisition circuit.

Q2: What should I do if the blood oxygen value measurement is inaccurate?

A2: Check if external factors are causing inaccurate measurements, such as measurement position or posture. First, clean the sensor probe. If the problem persists, check if the connection between the module board and the main board is loose, or replace the module board.

Q3: Can this module board be replaced separately?

A3: Yes, you need to disconnect the old board from the main board and the sensor, align the new board with the interface, and calibrate the blood oxygen parameters after restarting the device.

Q4: Is it normal for the module board to overheat? A4: Slight heating is normal; if it is too hot to touch, it may be due to a short circuit in the onboard components. You need to immediately disconnect the power and replace the module board to avoid damaging the motherboard.

Ordering Information
Payment Methods Bank Transfer / PayPal / Western Union
Shipping Methods DHL / FedEx

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Bella

Tel: 86-18879075074

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.