China World Technology Medical Equipment Service Group
Win-win together!
| Brand Name: | GE |
| Model Number: | 43367259 |
| Minimum Order Quantity: | 1 Piece |
|---|---|
| Price: | USD |
| Packaging Details: | Standard Export Packing |
| Delivery Time: | 3-5 working days |
| Payment Terms: | T/T,Western Union,Paypal |
| Brand: | GE | Product Category: | Monitoring |
|---|---|---|---|
| Product Type: | Spare Parts | Product Name: | NIBP Module |
| Model: | 43367259 | Machine Application: | Dash 2000 |
| Condition: | Used With Good Condition | Warranty: | 90 Days |
| Delivery Date: | 3 - 5 Working Days | Package: | Carton |
| Payment Method: | Western Union, Bank T/T, Paypal | Transportation: | DHL, FedEx, UPS, TNT, EMS, By Air, Etc. |
| MOQ: | One Piece | ||
| Highlight: | GE Dash 2000 NBP NIBP board,patient monitor replacement parts with warranty,OKEN SEIKO P05C06 rolling mini pump |
||
NIBP Assembly for Dash 2000
GE Dash 2000 Patient Monitor NBP NIBP Board 43367259 with Rolling Mini Pump OKEN SEIKO P05C06
► 1. Brief Description
The NBP NIBP Board 43367259 with Rolling Mini Pump is a crucial component of the GE DASH2000 patient monitor, serving as the core hardware for non-invasive blood pressure measurement. It automatically completes the entire inflation, measurement, and deflation process, processing the collected pressure signals to calculate systolic blood pressure, diastolic blood pressure, mean blood pressure, and heart rate.
The NBP NIBP Board with Rolling Mini Pump integrates the pump, solenoid valve, and circuitry onto a single, pluggable board, facilitating maintenance and replacement. If your DASH2000 monitor experiences a NIBP malfunction, you can typically repair it by replacing the entire board.
► 2. Detailed Photos
![]()
![]()
If a measurement cannot be completed, a status message will be displayed in the NBP value window. Below is a list of status messages in alphabetical order, including monitoring responses and the actions to be taken.
(1). Fault Symptom: Cuff inflation exceeds 5 minutes
* Monitoring Response: System status alarm. Automatic mode will be turned off.
* Solution: Check the cuff; if there is no air in the cuff, try measuring again.
(2). Fault Symptom: DEFLATION FAIL
* Monitoring Response: System status alarm. Automatic mode will be turned off.
* Solution: Remove the cuff and contact a service representative.
(3). Fault Symptom: Inflation failed, check cuff
* Monitoring Response: System status alarm.
* Solution: Check the cuff, connectors, and guide tubes; try another measurement.
(4). Fault Symptom: Maximum cuff pressure exceeded
* Monitoring Response: System status alarm. Automatic mode will be turned off.
* Solution: Remove the cuff and contact a service representative.
(5). Fault Symptom: Measurement time exceeded limit
* Monitoring Response: System status alarm.
* Solution: The patient may be overactive or have arrhythmia. Check the patient; try another measurement.
(6). Fault Manifestation: Hardware Failure
* Monitoring Response: System status alarm. Automatic mode will be turned off.
* Solution: Contact maintenance personnel.
► 4. NBP Test
![]()
Contact Person: Jasmine
Tel: 86-15180047496