logo
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

Biocare FM-801 Fetal Monitor Mainboard with 32-bit ARM Cortex-M4, 16-bit AD Converter, and 128MB Flash Memory

Biocare FM-801 Fetal Monitor Mainboard with 32-bit ARM Cortex-M4, 16-bit AD Converter, and 128MB Flash Memory

  • Biocare FM-801 Fetal Monitor Mainboard with 32-bit ARM Cortex-M4, 16-bit AD Converter, and 128MB Flash Memory
  • Biocare FM-801 Fetal Monitor Mainboard with 32-bit ARM Cortex-M4, 16-bit AD Converter, and 128MB Flash Memory
  • Biocare FM-801 Fetal Monitor Mainboard with 32-bit ARM Cortex-M4, 16-bit AD Converter, and 128MB Flash Memory
  • Biocare FM-801 Fetal Monitor Mainboard with 32-bit ARM Cortex-M4, 16-bit AD Converter, and 128MB Flash Memory
  • Biocare FM-801 Fetal Monitor Mainboard with 32-bit ARM Cortex-M4, 16-bit AD Converter, and 128MB Flash Memory
  • Biocare FM-801 Fetal Monitor Mainboard with 32-bit ARM Cortex-M4, 16-bit AD Converter, and 128MB Flash Memory
Biocare FM-801 Fetal Monitor Mainboard with 32-bit ARM Cortex-M4, 16-bit AD Converter, and 128MB Flash Memory
Product Details:
Brand Name: Biocare
Model Number: FM-801
Payment & Shipping Terms:
Minimum Order Quantity: 1 Piece
Price: USD
Packaging Details: Carton
Delivery Time: 3-5 working days
Payment Terms: T/T,Western Union,Paypal
Contact Now
Detailed Product Description
Product Name: Mainboard PN: 02040119-01
Condition: Good Working Microprocessor: 32-bit ARM Cortex-M4
AD Converter: 16-bit Resolution, Sampling Rate 100Hz Storage Capacity: 128MB Flash Memory
Alarm Type: Fetal Heart Rate Is Too High/too Low, Variability Is Reduced, And Uterine Contractions Are Too Frequent Alarm Mode: Sound And Light Alarm
Size: 180mm×120mm×1.6mm Weight: About 150g
Highlight:

32-bit ARM Cortex-M4 Fetal Monitor Mainboard

,

16-bit AD Converter Patient Monitor Mainboard

,

128MB Flash Memory Biocare FM-801 Mainboard

Biocare FM-801 Fetal Monitor Mainboard 02040119-01

The Biocare FM-801 Fetal Monitor Mainboard, model 02040119-01, serves as the central processing unit of the Biocare FM-801 fetal monitor. This critical component receives, analyzes, and processes raw sensor data while coordinating the operation of all monitor subsystems to ensure accurate fetal monitoring and stable device performance.

Key Features
Signal Processing

Professional signal analysis capabilities amplify and filter raw fetal heart rate and uterine contraction data. The digital signal processor converts this information into readable waveforms, enabling medical staff to quickly assess fetal condition and identify abnormalities.

System Coordination

Controls key components including display and printhead through dedicated interfaces. Executes user commands and provides visual feedback to support efficient clinical workflow.

Data Management

Built-in 128MB flash memory stores over 1,000 complete monitoring reports with export capability. Automated alarm system triggers when data exceeds preset safety thresholds, alerting medical staff to potential concerns.

Diagnostic Capabilities

Integrated self-test circuit performs automatic system checks during startup. Displays fault codes and indicator status to facilitate rapid troubleshooting and minimize equipment downtime.

Technical Specifications
Product Name Mainboard
Part Number 02040119-01
Compatible Device Biocare FM-801
Condition Good working
Processor 32-bit ARM Cortex-M4
AD Converter 16-bit resolution, 100Hz sampling rate
Storage Capacity 128MB flash memory
Alarm Types Fetal heart rate (high/low), reduced variability, frequent contractions
Alarm Mode Audible and visual alerts
Dimensions 180mm × 120mm × 1.6mm
Weight Approximately 150g
Biocare FM-801 Fetal Monitor Mainboard with 32-bit ARM Cortex-M4, 16-bit AD Converter, and 128MB Flash Memory 0 Biocare FM-801 Fetal Monitor Mainboard with 32-bit ARM Cortex-M4, 16-bit AD Converter, and 128MB Flash Memory 1
Frequently Asked Questions
Q: The monitor shows no fetal heart rate waveform despite normal probe indicator. What's wrong?

A: If the probe works on other devices, check mainboard signal connections. No signal input indicates interface failure; signal without waveform suggests mainboard processing unit failure requiring replacement.

Q: Fetal heart rate values jump frequently with confirmed probe/power board function. Cause?

A: Likely mainboard signal filtering or algorithm issue. Check for magnetic interference, recalibrate, and if problem persists, replace mainboard due to potential filter capacitor or DSP chip damage.

Q: "Storage Full" persists after report deletion. Solution?

A: Possible storage module failure or file system corruption. Attempt formatting. If USB export fails with storage errors, replace mainboard due to shared circuit failure between USB and storage modules.

Ordering Information
Payment Methods Bank Transfer / PayPal / Western Union
Shipping Methods DHL / FedEx

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Bella

Tel: 86-18879075074

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.