China World Technology Medical Equipment Service Group
Win-win together!
| Brand Name: | Dräger |
| Model Number: | 6737545 |
| Minimum Order Quantity: | 1 |
|---|---|
| Delivery Time: | 3-5 working days |
| Payment Terms: | ,Western Union,T/T |
| Brand: | Dräger | Moq: | 1 |
|---|---|---|---|
| Application Area: | ICU,medical Equipment | Measurement Parameters: | ECG, SpO2, NIBP, Temperature, CO2, IBP |
| Parameters: | ECG,TEMP,RESP,NIBP,SPO2 | Data Storage: | Internal Memory And External USB |
| Battery Capacity: | 2500 MAh, 7.56 VDC | Carryover: | WBC, RBC, HGB≤0.5%, PLT≤1% |
| Condiction: | Used | Mounting Options: | Wall Mount, Tabletop, And Cart |
| Rated Current: | 0.6A Maximum At 230V | Stock Situation: | Stock Available |
| Condition: | Used-Good | Payment: | T/T, Western Union, Paypal |
| Highlight: | Core Technical Functions Patient Monitor,6737545 Used Patient Monitor |
||
Dräger microfilter 6737545 Used Patient Monitor designed for Core Technical Functions
Dräger microfilter 6737545 Used Patient Monitor designed for Core Technical Functions serves as a critical barrier in respiratory protection systems. Its multi-layered composite structure integrates.
PRODUCT PICTURE:
![]()
medical-grade hydrophobic polytetrafluoroethylene (PTFE) microporous membrane as the primary filtration medium. This material undergoes an electret treatment process, imparting permanent electrostatic charges to the fiber surfaces. This dual mechanism enables:
Physical interception of particles >0.2 μm (including bacteria, viral droplets, and aerosols) via size exclusion;
Electrostatic adsorption of sub-micron particles (e.g., SARS-CoV-2 virions at 0.1 μm), achieving filtration efficiency ≥99.99% in compliance with ISO 23328-1:2020 standards.
Bidirectional Protection Technology
■ Patient-to-Equipment Protection:
During exhalation, pathogen-laden gases (containing organisms like Mycobacterium tuberculosis or influenza viruses) pass through a gradient density filter architecture:
A pre-filtration layer captures large particulates (>5 μm) such as respiratory secretions.
The PTFE membrane traps microorganisms, preventing contamination of anesthesia machine internals (e.g., flow sensors, gas pathways, vaporizers).
This significantly reduces cross-infection risks in ventilator sharing scenarios.
■ Equipment-to-Patient Protection:
The filter blocks pathogens colonizing ventilator internals (e.g., Pseudomonas aeruginosa) and airborne contaminants (OR particulates, fungal spores) from entering the patient's airway. Clinical studies demonstrate a 41% reduction in Ventilator-Associated Pneumonia (VAP) incidence when using ISO-certified filters.
Advanced Fluid Dynamics Design
Computational Fluid Dynamics (CFD) modeling optimizes airflow pathways to minimize resistance:
Peak flow resistance: ≤2.5 mbar at 300 L/min (35% lower than industry average).
Laminar flow channels maintain stable pressure delivery even during high-frequency oscillation ventilation (HFOV).
This low-resistance profile prevents respiratory muscle fatigue in compromised patients (COPD, ARDS) during prolonged mechanical ventilation.
Material Science Innovations
■ Hydrophobic Stability:
The PTFE membrane maintains structural integrity at 100% relative humidity without pore collapse, ensuring consistent filtration during humidified ventilation.
■ Dead Space Optimization:
Precision-molded polycarbonate housing limits internal volume to <15 ml, minimizing CO₂ rebreathing risk—critical for pediatric/neonatal applications where dead space >2 ml/kg can compromise gas exchange.
■ Chemical Compatibility:
Resists degradation by common disinfectants (ethanol, isopropanol) and anesthetic gases (sevoflurane, desflurane) per ASTM F2100 testing.
Performance Validation
Bacterial Filtration Efficiency (BFE): 99.999% against Staphylococcus aureus (3.0 μm)
Viral Filtration Efficiency (VFE): 99.99% against MS2 bacteriophage (0.025 μm)
Particulate Filtration: Meets EN 14387 P3 level (penetration <0.05%)
Pressure Drop: 1.8 mbar at 60 L/min (per ISO 9360-1:2022)
Clinical Applications
ICU ventilators requiring >72h continuous operation
Transport ventilators exposed to uncontrolled environments
Nebulizer circuits during aerosol-generating procedures (AGPs)
HFOV systems where conventional filters cause pressure oscillations
Regulatory Approvals
CE Marked (MDD 93/42/EEC), FDA 510(k) cleared (K191968), and TGA Australia listed (ARTG 337867).
Environmental Specifications
Operating Temp: -20°C to +50°C
Storage Humidity: <80% RH non-condensing
Shelf Life: 5 years in original packaging
|
Brand |
Dräger |
|
Product Name |
microfilter |
|
Model |
6737545 |
|
Condition |
used in good working |
|
Material |
Plastic |
|
Color |
white |
|
MOQ |
One Piece |
|
Payment Terms |
T/T(wire transfer), Western Union, Paypal |
|
Warranty |
90 days |
Contact Person: Rita
Tel: +8618279091952