China World Technology Medical Equipment Service Group
Win-win together!
| Brand Name: | GE |
| Model Number: | MSM6012 PN3896 12V 5A |
| Minimum Order Quantity: | 1pcs |
|---|---|
| Packaging Details: | Carton |
| Delivery Time: | 3-5 working days |
| Payment Terms: | T/T, Western Union,Paypal |
| Product Name: | GE Dash1800 Patient Monitor Power Supply Board MSM6012 PN3896 12V 5A | Brand: | GE |
|---|---|---|---|
| Part No: | MSM6012 PN3896 12V 5A | MOQ: | One Piece |
| Compatible With: | GE Dash1800 Patient Monitor | Condition: | Used |
| Payment Terms: | Full Before Shipment | Shipping Method: | DHL,Fedex ,UPS ,etc |
| Packaging: | Standard | Warranty: | 90 Days |
| Highlight: | MSM6012 Patient Monitor Power Supply Board,Patient Monitor Power Supply Board,PN3896 Patient Monitor Power Supply Board |
||
GE Dash1800 Patient Monitor Power Supply Board
MSM6012 PN3896 12V 5A
►Brief Introduction of GE Dash1800 Patient Monitor Power Supply Board MSM6012 PN3896 12V 5A
GE Dash1800 MSM6012 PN3896 12V 5A Patient Monitor Power Board. Converts external AC power or battery input into the DC voltage required by the monitor, and provides stable power to each module (motherboard, display, sensor, etc.).
► Common shootings of GE Dash1800 Patient Monitor Power Supply Board MSM6012 PN3896 12V 5A
► GE DASH1800 Patient monitor does not start
If the power board has no output, the monitor may be completely powered off. Check the fuses, rectifier bridges, and switching tubes for damage.
Abnormal power supply in battery mode may be related to the failure of the battery management circuit (such as the charging control chip) on the power board.
► Intermittent power outages or voltage fluctuations.
Old capacitors or poor heat dissipation will cause the output voltage to be unstable, resulting in automatic restart of the device and abnormal parameter monitoring.
The interface of the power board is oxidized or has poor contact, so the connection port needs to be cleaned or rewelded.
► Specification of GE Dash1800 Patient Monitor Power Supply Board MSM6012 PN3896 12V 5A
| Product Name |
GE Dash1800 Patient Monitor Power Supply Board MSM6012 PN3896 12V 5A
|
| Brand | GE |
| Part No | MSM6012 PN3896 12V 5A |
| Compatible With | GE Dash1800 Patient Monitor |
| MOQ | One piece |
| Warranty | 90 days |
| Condition | Used |
► CWT Technology HK Limited Main devices
Below list is our company’s main devices .If you need other devices or spare parts ,accessories ,feel free to contact us .
| Brand | Catalogue | Model no |
| GE | Patient monitor |
B105 ,B125,B450,B650 ,B20i ,B30 ,DASH3000,DASH4000,DASH5000,DASH2500,V100
|
| ECG/EKG | MAC800 ,MAC1200,MAC400 ,MAC5000 ,MAC5500 | |
| Defibrillator | Marquette Hellige Cardioserv | |
| Philip | Patient monitor |
MP20,MP30,MP40,MP50,MP60,MP70,MP80,MP90,VM4,VM6,VM8, MX600, MX700, MX800 ,MX400,MX450,MP5 X2 ,MP2,VSi ,VS2 VS3 VS4
|
| Fetal monitor | FM20 FM30 | |
| ECG/EKG | TC10,TC20,TC30 | |
| Defibrillator | M4735A XL,XL+,MRX , | |
|
Mindray
|
Patient monitor |
MEC-1000,MEC-2000,IMEC10,IMEC12,BeneVision N1 MP6000,MP7000,MP8000,MP9000 BeneView T5 ,BeneView T6,BeneView T8
|
| Defibrillator | D1,D2,D3,D5,D6, | |
| Nihon Kohden | ECG/EKG |
ECG 1250P,ECG-1250A,ECG-1350,cardiofax S,cardiofax Q
|
| Defibrillator |
TEC-5521C,TEC-5531C,TEC-5631C,TEC-7621C,TEC-7631C
|
|
|
Zoll
|
Defibrillator | M Series |
| Medtronic | Defibrillator | Lifepack 12 ,lifepack 20 ,lifepack 1000 |
| Masimo | pulse oximeter | Masimo SET Radical-7 pulse oximeter |
![]()
Thank you so much for your attention .If you're interested in GE Dash1800 Patient Monitor Power Supply Board MSM6012 PN3896 12V 5A,feel free to contact us .Thank you .
Contact Person: Kiara
Tel: 8619854815217