China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | Mindray |
Model Number: | 115-036653-01 |
Minimum Order Quantity: | 1 Piece |
---|---|
Price: | USD |
Delivery Time: | 3-5 working days |
Payment Terms: | T/T, Western Union, Paypal |
Brand:: | Mindray | Product Name:: | Patient Monitor Module |
---|---|---|---|
Model:: | 115-036653-01 MPM Platinum | Module Type:: | Multi-Parameter Module |
Type:: | Spare Parts | Condition:: | Used-Good |
Application:: | Mindray BeneVision N-series Monitor (such As N12C, N12, N15, N17, N19) | MOQ:: | 1 Piece |
Warranty:: | 90 Days | Serve:: | Direct Sales, Exchanges, Repairs |
High Light: | 115-036653-01 MPM Platinum Multi-Parameter Module,MPM Platinum Multi-Parameter Module |
► Brief Introduction
The Mindray MPM(Multi-Parameter Module) Platinum Module 115-036653-01 is compatible with Mindray BeneVision N-Series patient monitor, include N12C, N12, N15, N17, N19, etc. The module has 2 hard keys, they are in the first row of the module control panel. The first one from left to right is the setup hard key, which can be used to enter or exit the MPM setup menu. The module has 2 hard keys, which are located in the first row of the module control panel. The first one from left to right is the Setup hard key, which can be used to enter or exit the MPM setup menu. The second one from left to right is the Zero hard key, which can be used to enter the Zero IBP menu. The rightmost connector on the first row is an analog output connector, which can output analog signals of defibrillation synchronization pulse, ECG and IBP.
There is also an indicator light below the Zero hard key. When the indicator light is always on, it means that the module is working properly. When the indicator light flashes, it means that the module is initializing. When the indicator light is off, it means that the module is not connected or the module is faulty.
► Features
This Mindray MPM(Multi-Parameter Module) Platinum Module 115-036653-01 can measured many parameter such as ECG, SpO2, IBP monitoring, Respiration, Dual Invasive Blood Pressures, Temperature, NIBP.
The module needs to be used and stored in a suitable environment. The operating environment temperature should be between 0-40 degrees Celsius, the humidity should be between 15% and 95%, and the air pressure should be between 427.5 mmHg and 805.5 mmHg. The storage environment temperature should be between -20-60 degrees Celsius, the humidity should be between 10% and 95%, and the air pressure should be between 120 mmHg and 805.5 mmHg.
Please note that when the Mindray BeneVision N-Series monitor is connected to the module, only one MPM module can be used at a time, and no other modules can be used during this period. Otherwise, there will be conflicts between the modules and they cannot be used, and the monitor will also issue a prompt of module conflict.
► Parameters
Brand: | Mindray |
Product Name: |
Patient Monitor Module |
Model: |
115-036653-01 MPM Platinum |
Module Type: | Multi-Parameter Module |
Type: | Spare Parts |
Condition: |
Used-Good |
Application: | Mindray BeneVision N-series Monitor (such as N12C, N12, N15, N17, N19) |
MOQ: | 1 Piece |
Warranty: |
90 Days |
Serve: |
Direct Sales, Exchanges, Repairs |
PAYMENT TERMS: |
Pay In Full Before Shipment |
► Product Picture
If you have any question about our Mindray MPM Platinum Module 115-036653-01, please feel free to contact us.
In addition, our company is mainly engaged in the sale, exchange and repair of medical equipment and medical equipment accessories. If you are also interested in other medical equipment and accessories, please feel free to contact us.
► After-sales issues
Our warranty time is 90 days after delivery. Before packing, we will check the goods model carefully, and if the product is in used condition, there are professional engineers who will test the functions of it. Only the test is qualified then we will pack carefully to ensure that you can receive satisfactory and workable goods. And please check the goods asap after you receiving them. If you have any questions, please feel free to contact us.
Contact Person: Bella Liu
Tel: +8618879075074