GE Gas Module M-CAIO
GE Datex-Ohmeda 5 Agent Gas Module M-CAIO M-CAIO-02 Used for Monitor
► Brief Description
GE Datex-Ohmeda 5 Agent Gas Module M-CAIO M-CAIO-02
GE Gas Module M-CAIO M-CAIO-02 - This module is a gas monitoring or gas delivery related product that can monitor or control gas composition. It is designed for use with the S/5 monitor and its main function is to provide airway and respiratory measurements. Different letters represent different meanings:
M = plug-in module
C = CO2 and N2O
O = patient O2
If you need more details, please feel free to contact us.
► More Details
1 | CPU board, Compact Airway Module |
2 | PVX unit, Compact Airway Module |
3 | Sampling pump, Compact Airway Module |
4 | Special tube, 300mm |
5 | Fan, Compact Airway Module |
6 | Fan filter |
7 | Fan filter cover |
8 | Filter |
9 | O-ring |
10 | Insulation plate |
11 | Module box (double width) |
12 | Latch |
13 | Spring pin |
14 | Cable tie |
15 | Cross recess screw UNC4-40 |
16 | Cross cylinder-head screw M3x6 |
17 | Cross cylinder-head screw M3x6 |
21 | Front panel sticker, plain |
► Detailed Photos
► Notes
1. Do not use the same module simultaneously on the same monitor device. M-C, M-CO, M-COV, M-COVX, M-CAiO, M-CAiOV, M-CAiOVX and M-CAiOVX/SERVICE are considered the same module.
2. The Compact Airway Module cannot be used in the expansion frame F-EXT4.
3. Anesthetic and N2O values will not be displayed in the Critical Care main software, but compensation for CO2 and O2 will be calculated when they are present in the module.
4. Calibration is not recommended before the 30 minute warm-up time.
► Maintenance
- Regularly check the connection lines, including power lines, signal lines, etc., to see if they are loose, damaged or aged.
- Check the performance of the sensor and observe its response time and stability.
- Check the overall operating status of the module to see if there is abnormal heating, odor, noise, etc.
- Clean the module housing, wipe it with a clean, soft damp cloth to remove dust and stains on the surface, and avoid using corrosive or highly irritating detergents to prevent damage to the housing.