Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

PHiliph Goldway UT6000A Patient Monitor NIBP Module C-NIBP312B 09-03-16 V1

PHiliph Goldway UT6000A Patient Monitor NIBP Module C-NIBP312B 09-03-16 V1

  • PHiliph Goldway UT6000A Patient Monitor NIBP Module C-NIBP312B 09-03-16 V1
  • PHiliph Goldway UT6000A Patient Monitor NIBP Module C-NIBP312B 09-03-16 V1
  • PHiliph Goldway UT6000A Patient Monitor NIBP Module C-NIBP312B 09-03-16 V1
  • PHiliph Goldway UT6000A Patient Monitor NIBP Module C-NIBP312B 09-03-16 V1
PHiliph Goldway UT6000A Patient Monitor NIBP Module C-NIBP312B 09-03-16 V1
Product Details:
Brand Name: Goldway
Model Number: UT6000A
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Features: Professional, Reliable,Economic Product Name: Goldway Mainboard
Type: UT4000AUT6000A Warranty: 90days
Power Supply Source: Electric Mode Of Transport: Express Delivery
AC Input Voltage Rate: 100 V ~ 240 V Languages: Chinese, English, French, Italian, Polish, Russian,Turkish, Spanish, Portuguese, Czech
Method:: Automatic Oscillometric Parameters:: SYS/DIA/MAP/Pulse Rate
Operating Modes:: Manual/Auto/STAT Auto Measure Time:: 1-10, 15, 30, 60, 90, 120, 180, 240, 480 Minute Intervals
Units:: MmHg/kPa Over-pressure Protection:: Yes
Cuff Pressure Range:: Adult/Pediatric 0 – 300 MmHg Neonate 0 – 150 MmHg
Highlight:

Patient Monitor NIBP Module

,

UT6000A Patient Monitor NIBP Module

,

09-03-16 V1 NIBP Module

 

 

PHiliphh Goldway UT6000A Patient Monitor NIBP Module C-NIBP312B 09-03-16 V1

 

 

 

►Brief Introduction

NIBP processing uses an oscilloscope technique to provide needed measurements at selected intervals. This technique uses an inflatable sphygmomanometer cuff similar to those used by clinicians in routine measurements. A motorized pump inflates the cuff to approximately 170 mm Hg (adult mode) initially, at which point the pressure effectively stops the flow of blood. Then, under monitor control, the pressure in the cuff is gradually reduced, while a pressure transducer detects the pressure and transmits the parameter signal to the NIBP input circuitry. As the pressure is reduced, blood flows in the previously occluded artery, and changes the measurements made by the transducer. The point at which oscillation increases sharply is defined as systolic pressure. As the cuff continues to deflate, the oscillation amplitude increases to a maximum, and then decreases. The peak oscillation amplitude is defined as the mean arterial pressure. The point at which the system detects a rapid decrease in oscillation is defined as the diastolic pressure.

 

 

 

► Processing the NIBP

The NIBP assembly and circuitry contain the following elements:

  • Pump
  • Valves
  • Manifold
  • Filter
  • Pressure measurement and control circuitry

Pressure data is converted to digital format and conveyed to the processor. The NIBP pump uses an oscillometric method that drives stepwise pressure deflation. Pump software eliminates most ambient noise and motion interference. It can be applied to neonatal, pediatric and adult patients. The blood pressure range for Systolic is 30-254 mmHg and Diastolic 10-220 mmHg. Accuracy is Maximum Mean Error ±5 mmHg, with Maximum Standard Deviation no greater than 8 mmHg.

 

 

 

► Performing NIBP Test

An authorized service representative should perform pressure tests and parameter calibration every 12 months or whenever you suspect incorrect blood pressure readings. Always check to see if the cuff or hose has a leak. Replace the cuff or hose as necessary.

If the pressure reading is compared with a precise blood pressure meter, and the difference is more than ±3mmHg, the monitor needs pressure calibration. Authorized personnel can perform the required calibration.

The following tests verify the performance of the non-invasive blood pressure measurement.

  • NIBP accuracy
  • NIBP overpressure valve
  • NIBP calibration procedure (if required)

 

 

Specification

Method: Automatic Oscillometric
Parameters: SYS/DIA/MAP/Pulse Rate
Operating modes: Manual/Auto/STAT
Auto measure time: 1-10, 15, 30, 60, 90, 120, 180, 240, 480 minute intervals
Units: mmHg/kPa
Over-pressure protection: Yes
Cuff pressure range: Adult/Pediatric 0 – 300 mmHg
Neonate 0 – 150 mmHg
Measurement range: (SYS) Adult/Pediatric 30 mmHg – 254 mmHg (4.0kPa – 33.9kPa)
Neonate 30 mmHg – 135 mmHg (4.0kPa – 18.0kPa)
Measurement range: (DIA) Adult/Pediatric 10 mmHg – 220 mmHg (1.3kPa – 29.3kPa)
Neonate 10 mmHg – 110 mmHg (1.3kPa – 14.7kPa)

 

PHiliph Goldway UT6000A Patient Monitor NIBP Module C-NIBP312B 09-03-16 V1 0

 

 

 

If you want to explore more details about PHiliphh Goldway UT6000A Patient Monitor NIBP Module C-NIBP312B 09-03-16 V1, please let us know. Looking forward to receiving your early inquiry.

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Bella

Tel: 86-18879075074

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2025 patients-monitor.com. All Rights Reserved.